Product comparison · 2 power distribution units (pdus)

APC NetShelter power distribution unit (PDU) 40 AC outlet(s) 0U Black vs Lindy 32623 power distribution unit (PDU) 8 AC outlet(s) 1U Black

Add a product
  • 17specifications compared
  • 15differ
  • 2identical
  • 17known for one product only

Key differences

The Lindy 32623 power distribution unit (PDU) 8 AC outlet(s) 1U Black has 1 U more rack capacity than the APC NetShelter power distribution unit (PDU) 40 AC outlet(s) 0U Black (1U vs 0U). The APC NetShelter power distribution unit (PDU) 40 AC outlet(s) 0U Black has 1 more Ethernet LAN (RJ-45) ports than the Lindy 32623 power distribution unit (PDU) 8 AC outlet(s) 1U Black (5 vs 4). The APC NetShelter power distribution unit (PDU) 40 AC outlet(s) 0U Black has 8 A more maximum current than the Lindy 32623 power distribution unit (PDU) 8 AC outlet(s) 1U Black (24 A vs 16 A). PDU types: Metered on the APC NetShelter power distribution unit (PDU) 40 AC outlet(s) 0U Black, Metered, Switched on the Lindy 32623 power distribution unit (PDU) 8 AC outlet(s) 1U Black. AC outlets quantity: 40 AC outlet(s) on the APC NetShelter power distribution unit (PDU) 40 AC outlet(s) 0U Black, 8 AC outlet(s) on the Lindy 32623 power distribution unit (PDU) 8 AC outlet(s) 1U Black.

  • PDU types
    • NetShelter power distribution unit (PDU) 40 AC outlet(s) 0U Black:Metered
    • 32623 power distribution unit (PDU) 8 AC outlet(s) 1U Black:Metered, Switched
  • Rack capacity
    • NetShelter power distribution unit (PDU) 40 AC outlet(s) 0U Black:0U
    • 32623 power distribution unit (PDU) 8 AC outlet(s) 1U Black:1U
  • AC outlets quantity
    • NetShelter power distribution unit (PDU) 40 AC outlet(s) 0U Black:40 AC outlet(s)
    • 32623 power distribution unit (PDU) 8 AC outlet(s) 1U Black:8 AC outlet(s)
  • Ethernet LAN (RJ-45) ports
    • NetShelter power distribution unit (PDU) 40 AC outlet(s) 0U Black:5
    • 32623 power distribution unit (PDU) 8 AC outlet(s) 1U Black:4
  • Nominal input voltage
    • NetShelter power distribution unit (PDU) 40 AC outlet(s) 0U Black:208 V
    • 32623 power distribution unit (PDU) 8 AC outlet(s) 1U Black:110 - 250 V
  • Maximum current
    • NetShelter power distribution unit (PDU) 40 AC outlet(s) 0U Black:24 A
    • 32623 power distribution unit (PDU) 8 AC outlet(s) 1U Black:16 A
  • Width
    • NetShelter power distribution unit (PDU) 40 AC outlet(s) 0U Black:56 mm
    • 32623 power distribution unit (PDU) 8 AC outlet(s) 1U Black:436 mm
  • Depth
    • NetShelter power distribution unit (PDU) 40 AC outlet(s) 0U Black:75 mm
    • 32623 power distribution unit (PDU) 8 AC outlet(s) 1U Black:225 mm

Side by side

Differences highlightedShow differences only (off)
Comparison of NetShelter, 32623
34 specifications
Design2 differ
PDU typesDiffersMeteredMetered, Switched
Rack capacityDiffers0U1U
Housing materialKnown for oneUnknown — not stated by the sourceMetal
Product colourBlackBlack
TypeKnown for oneSingle-phaseUnknown — not stated by the source
Ports & interfaces3 differ
AC outlets quantityDiffers40 AC outlet(s)8 AC outlet(s)
Power plugKnown for oneUnknown — not stated by the sourceC20 coupler
AC outlet typesDiffersC13 coupler, C15 coupler, C19 coupler, C21 couplerC13 coupler
Serial ports quantityKnown for oneUnknown — not stated by the source1
Ethernet LAN (RJ-45) portsDiffers54
Management featuresidentical
MonitoringKnown for oneUnknown — not stated by the sourceVoltage, Current, Power
Management platformKnown for oneNMC3Unknown — not stated by the source
Power2 differ
Nominal input voltageDiffers208 V110 - 250 V
AC input frequency50/60 Hz50/60 Hz
Maximum currentDiffers24 A16 A
Maximum powerKnown for oneUnknown — not stated by the source2500 W
Nominal output voltageKnown for one208 VUnknown — not stated by the source
Load capacityKnown for one4992 VAUnknown — not stated by the source
Number of phasesKnown for one1Unknown — not stated by the source
Certificatesidentical
Compliance certificatesKnown for oneUnknown — not stated by the sourceCE, UKCA, RoHS, REACH, Electromagnetic Compatibility (EMC), Low Voltage Directive (LVD), Federal Communications Commission (FCC)
CertificationKnown for oneUKCA, CE, EN 62368-1, RoHSUnknown — not stated by the source
Operational conditionsidentical
Operating temperature (T-T)Known for oneUnknown — not stated by the source-5 - 55 °C
Storage temperature (T-T)Known for oneUnknown — not stated by the source-20 - 70 °C
Operating relative humidity (H-H)Known for oneUnknown — not stated by the source0 - 80%
Weight & dimensions4 differ
WidthDiffers56 mm436 mm
DepthDiffers75 mm225 mm
HeightDiffers1490 mm44 mm
WeightDiffers6.2 kg1.1 kg
Packaging contentidentical
Cables includedKnown for oneUnknown — not stated by the sourcePower, Serial
ManualKnown for oneUnknown — not stated by the sourceYes
Packaging data4 differ
Package weightDiffers8.2 kg2.5 kg
Package widthDiffers116 mm540 mm
Package depthDiffers208 mm422 mm
Package heightDiffers1720 mm87 mm

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.

More power distribution units (pdus) comparisons