Product comparison · 2 power distribution units (pdus)

APC NetShelter power distribution unit (PDU) 40 AC outlet(s) 0U Black vs APC NetShelter Rack PDU Advanced Gen 2, Metered, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlets

Add a product
  • 23specifications compared
  • 5differ
  • 18identical
  • 15known for one product only

Key differences

The APC NetShelter Rack PDU Advanced Gen 2, Metered, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlets has 8 A more maximum current than the APC NetShelter power distribution unit (PDU) 40 AC outlet(s) 0U Black (32 A vs 24 A). The APC NetShelter Rack PDU Advanced Gen 2, Metered, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlets has 22 V more nominal output voltage than the APC NetShelter power distribution unit (PDU) 40 AC outlet(s) 0U Black (230 V vs 208 V). The APC NetShelter Rack PDU Advanced Gen 2, Metered, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlets has 2,408 VA more load capacity than the APC NetShelter power distribution unit (PDU) 40 AC outlet(s) 0U Black (7400 VA vs 4992 VA). Nominal input voltage: 208 V on the APC NetShelter power distribution unit (PDU) 40 AC outlet(s) 0U Black, 230 1 phase on the APC NetShelter Rack PDU Advanced Gen 2, Metered, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlets. Certification: UKCA, CE, EN 62368-1, RoHS on the APC NetShelter power distribution unit (PDU) 40 AC outlet(s) 0U Black, UKCA on the APC NetShelter Rack PDU Advanced Gen 2, Metered, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlets.

  • Nominal input voltage
    • NetShelter power distribution unit (PDU) 40 AC outlet(s) 0U Black:208 V
    • NetShelter Rack PDU Advanced Gen 2, Metered, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlets:230 1 phase
  • Maximum current
    • NetShelter power distribution unit (PDU) 40 AC outlet(s) 0U Black:24 A
    • NetShelter Rack PDU Advanced Gen 2, Metered, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlets:32 A
  • Nominal output voltage
    • NetShelter power distribution unit (PDU) 40 AC outlet(s) 0U Black:208 V
    • NetShelter Rack PDU Advanced Gen 2, Metered, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlets:230 V
  • Load capacity
    • NetShelter power distribution unit (PDU) 40 AC outlet(s) 0U Black:4992 VA
    • NetShelter Rack PDU Advanced Gen 2, Metered, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlets:7400 VA
  • Certification
    • NetShelter power distribution unit (PDU) 40 AC outlet(s) 0U Black:UKCA, CE, EN 62368-1, RoHS
    • NetShelter Rack PDU Advanced Gen 2, Metered, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlets:UKCA

Side by side

Differences highlightedShow differences only (off)
Comparison of NetShelter, NetShelter Rack PDU Advanced Gen 2, Metered, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlets
38 specifications
Designidentical
PDU typesMeteredMetered
TypeSingle-phaseSingle-phase
Rack capacity0U0U
Product colourBlackBlack
Ports & interfacesidentical
AC outlets quantity40 AC outlet(s)40 AC outlet(s)
AC outlet typesC13 coupler, C15 coupler, C19 coupler, C21 couplerC13 coupler, C15 coupler, C19 coupler, C21 coupler
Ethernet LAN (RJ-45) ports55
USB ports quantityKnown for oneUnknown — not stated by the source1
Input connection typeKnown for oneUnknown — not stated by the sourceIEC 60309 32 A 2P + PE
Featuresidentical
Cable lengthKnown for oneUnknown — not stated by the source3 m
Management featuresidentical
Management platformNMC3NMC3
Power4 differ
Nominal input voltageDiffers208 V230 1 phase
AC input frequency50/60 Hz50/60 Hz
Maximum currentDiffers24 A32 A
Nominal output voltageDiffers208 V230 V
Output voltageKnown for oneUnknown — not stated by the source230 V
Load capacityDiffers4992 VA7400 VA
Number of phases11
Battery replacement accessibilityKnown for oneUnknown — not stated by the sourceNon-removable
Certificates1 differ
Compliance certificatesKnown for oneUnknown — not stated by the sourceRoHS, REACH, WEEE
Waste Electrical and Electronic Equipment (WEEE) complianceKnown for oneUnknown — not stated by the sourceYes
CertificationDiffersUKCA, CE, EN 62368-1, RoHSUKCA
Weight & dimensionsidentical
Width56 mm56 mm
Depth75 mm75 mm
Height1490 mm1490 mm
Weight6.2 kg6.2 kg
Packaging dataidentical
Package weight8.2 kg8.2 kg
Package width116 mm116 mm
Package depth208 mm208 mm
Package height1720 mm1720 mm
Technical detailsidentical
Preferred mounting positionKnown for oneUnknown — not stated by the sourceno preference
Removable batteryKnown for oneUnknown — not stated by the sourceNo
Packaging without single use plasticKnown for oneUnknown — not stated by the sourceNo
SCIP numberKnown for oneUnknown — not stated by the source31346aed-552c-4a16-81d9-e683a383b6da
Sustainable packagingKnown for oneUnknown — not stated by the sourceNo
Take-back systemKnown for oneUnknown — not stated by the sourceNo
Logistics dataidentical
Country of originKnown for oneUnknown — not stated by the sourceUnited States
Customs product code (TARIC)Known for oneUnknown — not stated by the source8537109899