Product comparison · 2 power distribution units (pdus)

APC NetShelter Rack PDU Advanced Switched Metered, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets vs Vertiv MN00X1R1-16MCQ9-3TL14A0A10-S power distribution unit (PDU) 16 AC outlet(s) 1U Black

Add a product
  • 15specifications compared
  • 12differ
  • 3identical
  • 17known for one product only

Key differences

The APC NetShelter Rack PDU Advanced Switched Metered, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets has 1 U more rack capacity than the Vertiv MN00X1R1-16MCQ9-3TL14A0A10-S power distribution unit (PDU) 16 AC outlet(s) 1U Black (2U vs 1U). The APC NetShelter Rack PDU Advanced Switched Metered, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets has 30 A more maximum current than the Vertiv MN00X1R1-16MCQ9-3TL14A0A10-S power distribution unit (PDU) 16 AC outlet(s) 1U Black (60 A vs 30 A). The APC NetShelter Rack PDU Advanced Switched Metered, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets has 11,600 VA more load capacity than the Vertiv MN00X1R1-16MCQ9-3TL14A0A10-S power distribution unit (PDU) 16 AC outlet(s) 1U Black (17300 VA vs 5700 VA). PDU types: Metered-by-outlet, Switched on the APC NetShelter Rack PDU Advanced Switched Metered, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets, Basic on the Vertiv MN00X1R1-16MCQ9-3TL14A0A10-S power distribution unit (PDU) 16 AC outlet(s) 1U Black. AC outlets quantity: 18 AC outlet(s) on the APC NetShelter Rack PDU Advanced Switched Metered, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets, 16 AC outlet(s) on the Vertiv MN00X1R1-16MCQ9-3TL14A0A10-S power distribution unit (PDU) 16 AC outlet(s) 1U Black.

  • PDU types
    • NetShelter Rack PDU Advanced Switched Metered, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets:Metered-by-outlet, Switched
    • MN00X1R1-16MCQ9-3TL14A0A10-S power distribution unit (PDU) 16 AC outlet(s) 1U Black:Basic
  • Rack capacity
    • NetShelter Rack PDU Advanced Switched Metered, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets:2U
    • MN00X1R1-16MCQ9-3TL14A0A10-S power distribution unit (PDU) 16 AC outlet(s) 1U Black:1U
  • AC outlets quantity
    • NetShelter Rack PDU Advanced Switched Metered, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets:18 AC outlet(s)
    • MN00X1R1-16MCQ9-3TL14A0A10-S power distribution unit (PDU) 16 AC outlet(s) 1U Black:16 AC outlet(s)
  • Power plug
    • NetShelter Rack PDU Advanced Switched Metered, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets:IEC309
    • MN00X1R1-16MCQ9-3TL14A0A10-S power distribution unit (PDU) 16 AC outlet(s) 1U Black:NEMA L14-30P
  • Nominal input voltage
    • NetShelter Rack PDU Advanced Switched Metered, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets:208 V
    • MN00X1R1-16MCQ9-3TL14A0A10-S power distribution unit (PDU) 16 AC outlet(s) 1U Black:100 - 240 V
  • Maximum current
    • NetShelter Rack PDU Advanced Switched Metered, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets:60 A
    • MN00X1R1-16MCQ9-3TL14A0A10-S power distribution unit (PDU) 16 AC outlet(s) 1U Black:30 A
  • Load capacity
    • NetShelter Rack PDU Advanced Switched Metered, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets:17300 VA
    • MN00X1R1-16MCQ9-3TL14A0A10-S power distribution unit (PDU) 16 AC outlet(s) 1U Black:5700 VA
  • Width
    • NetShelter Rack PDU Advanced Switched Metered, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets:443 mm
    • MN00X1R1-16MCQ9-3TL14A0A10-S power distribution unit (PDU) 16 AC outlet(s) 1U Black:50.8 mm

Side by side

Differences highlightedShow differences only (off)
Comparison of NetShelter Rack PDU Advanced Switched Metered, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets, MN00X1R1-16MCQ9-3TL14A0A10-S
32 specifications
Design2 differ
PDU typesDiffersMetered-by-outlet, SwitchedBasic
TypeKnown for oneThree-phaseUnknown — not stated by the source
Rack capacityDiffers2U1U
MountingHorizontalHorizontal
Product colourBlackBlack
On/off switchKnown for oneUnknown — not stated by the sourceYes
Ports & interfaces3 differ
AC outlets quantityDiffers18 AC outlet(s)16 AC outlet(s)
Power plugDiffersIEC309NEMA L14-30P
AC outlet typesDiffersC13 coupler, C15 coupler, C19 coupler, C21 couplerNEMA 5-20R, C13 coupler
Featuresidentical
International Protection (IP) codeKnown for oneIP44Unknown — not stated by the source
Cable lengthKnown for oneUnknown — not stated by the source3 m
Power3 differ
Nominal input voltageDiffers208 V100 - 240 V
AC input frequency50/60 Hz50/60 Hz
Maximum currentDiffers60 A30 A
Output voltageKnown for one208 VUnknown — not stated by the source
Load capacityDiffers17300 VA5700 VA
Nominal output voltageKnown for oneUnknown — not stated by the source208 V
Maximum powerKnown for oneUnknown — not stated by the source5700 W
Operational conditionsidentical
Operating temperature (T-T)Known for one-5 - 60 °CUnknown — not stated by the source
Storage temperature (T-T)Known for one-20 - 60 °CUnknown — not stated by the source
Operating relative humidity (H-H)Known for one5 - 90%Unknown — not stated by the source
Storage relative humidity (H-H)Known for one5 - 95%Unknown — not stated by the source
Non-operating altitudeKnown for one0 - 15240 mUnknown — not stated by the source
Weight & dimensions4 differ
WidthDiffers443 mm50.8 mm
DepthDiffers750 mm50.8 mm
HeightDiffers85 mm1682.7 mm
WeightDiffers16.5 kg6.8 kg
Packaging dataidentical
Package weightKnown for one23 kgUnknown — not stated by the source
Package widthKnown for one600 mmUnknown — not stated by the source
Package depthKnown for one165 mmUnknown — not stated by the source
Package heightKnown for one940 mmUnknown — not stated by the source
Certificatesidentical
Compliance certificatesKnown for oneUnknown — not stated by the sourceTrade Agreements Act (TAA), UL, cUL, RoHS

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.