Product comparison · 2 power distribution units (pdus)

APC NetShelter Rack PDU Advanced Switched, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets vs CyberPower PDU41021 power distribution unit (PDU) 16 AC outlet(s) 1U Black

Add a product
  • 23specifications compared
  • 20differ
  • 3identical
  • 17known for one product only

Key differences

The APC NetShelter Rack PDU Advanced Switched, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets has 1 U more rack capacity than the CyberPower PDU41021 power distribution unit (PDU) 16 AC outlet(s) 1U Black (2U vs 1U). The APC NetShelter Rack PDU Advanced Switched, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets has 88 V more nominal input voltage than the CyberPower PDU41021 power distribution unit (PDU) 16 AC outlet(s) 1U Black (208 V vs 120 V). The APC NetShelter Rack PDU Advanced Switched, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets has 45 A more maximum current than the CyberPower PDU41021 power distribution unit (PDU) 16 AC outlet(s) 1U Black (60 A vs 15 A). Type: Three-phase on the APC NetShelter Rack PDU Advanced Switched, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets, Single-phase on the CyberPower PDU41021 power distribution unit (PDU) 16 AC outlet(s) 1U Black. AC outlets quantity: 18 AC outlet(s) on the APC NetShelter Rack PDU Advanced Switched, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets, 16 AC outlet(s) on the CyberPower PDU41021 power distribution unit (PDU) 16 AC outlet(s) 1U Black.

  • Type
    • NetShelter Rack PDU Advanced Switched, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets:Three-phase
    • PDU41021 power distribution unit (PDU) 16 AC outlet(s) 1U Black:Single-phase
  • Rack capacity
    • NetShelter Rack PDU Advanced Switched, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets:2U
    • PDU41021 power distribution unit (PDU) 16 AC outlet(s) 1U Black:1U
  • AC outlets quantity
    • NetShelter Rack PDU Advanced Switched, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets:18 AC outlet(s)
    • PDU41021 power distribution unit (PDU) 16 AC outlet(s) 1U Black:16 AC outlet(s)
  • Power plug
    • NetShelter Rack PDU Advanced Switched, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets:IEC309
    • PDU41021 power distribution unit (PDU) 16 AC outlet(s) 1U Black:NEMA 5-15P
  • Nominal input voltage
    • NetShelter Rack PDU Advanced Switched, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets:208 V
    • PDU41021 power distribution unit (PDU) 16 AC outlet(s) 1U Black:120 V
  • AC input frequency
    • NetShelter Rack PDU Advanced Switched, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets:50/60 Hz
    • PDU41021 power distribution unit (PDU) 16 AC outlet(s) 1U Black:50-60 Hz
  • Maximum current
    • NetShelter Rack PDU Advanced Switched, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets:60 A
    • PDU41021 power distribution unit (PDU) 16 AC outlet(s) 1U Black:15 A
  • Operating temperature (T-T)
    • NetShelter Rack PDU Advanced Switched, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets:-5 - 60 °C
    • PDU41021 power distribution unit (PDU) 16 AC outlet(s) 1U Black:32 - 140 °F

Side by side

Differences highlightedShow differences only (on)
Comparison of NetShelter Rack PDU Advanced Switched, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets, PDU41021
40 specifications
Design2 differ
TypeDiffersThree-phaseSingle-phase
Rack capacityDiffers2U1U
Housing materialKnown for oneUnknown — not stated by the sourceMetal
DisplayKnown for oneUnknown — not stated by the sourceLCD
On/off switchKnown for oneUnknown — not stated by the sourceYes
Ports & interfaces3 differ
AC outlets quantityDiffers18 AC outlet(s)16 AC outlet(s)
Power plugDiffersIEC309NEMA 5-15P
AC outlet typesDiffersC13 coupler, C15 coupler, C19 coupler, C21 couplerNEMA 5-15R
Ethernet LAN (RJ-45) portsKnown for oneUnknown — not stated by the source2
Featuresidentical
Daisy chainKnown for oneUnknown — not stated by the sourceYes
Reset buttonKnown for oneUnknown — not stated by the sourceYes
Cable lengthKnown for oneUnknown — not stated by the source3.7 m
International Protection (IP) codeKnown for oneIP44Unknown — not stated by the source
Management featuresidentical
MonitoringKnown for oneUnknown — not stated by the sourceCurrent, Power, Energy, Temperature, Humidity, Voltage, Alarm
Management platformKnown for oneUnknown — not stated by the sourceSNMP
Supported network protocolsKnown for oneUnknown — not stated by the sourceIPv4/v6, SNMPv1/v3, HTTP/HTTPs, TCP/IP, UDP, DHCP, NTP, DNS, SMTP, SSH, SSL, TLS, Telnet, FTP, and Syslog, RADIUS, LDAP, LDAPS, Windows AD
Power3 differ
Nominal input voltageDiffers208 V120 V
AC input frequencyDiffers50/60 Hz50-60 Hz
Maximum currentDiffers60 A15 A
Nominal output voltageKnown for oneUnknown — not stated by the source100-120 V
Output voltageKnown for one208 VUnknown — not stated by the source
Load capacityKnown for one17300 VAUnknown — not stated by the source
Certificatesidentical
Compliance certificatesKnown for oneUnknown — not stated by the sourceUL, Federal Communications Commission (FCC), RoHS
Operational conditions4 differ
Operating temperature (T-T)Differs-5 - 60 °C32 - 140 °F
Storage temperature (T-T)Differs-20 - 60 °C-15 - 65 °C
Operating relative humidity (H-H)Differs5 - 90%0 - 95%
Operating altitudeKnown for oneUnknown — not stated by the source0 - 3500 m
Non-operating altitudeDiffers0 - 15240 m0 - 14999 m
Storage relative humidity (H-H)Known for one5 - 95%Unknown — not stated by the source
Weight & dimensions4 differ
WidthDiffers443 mm433 mm
DepthDiffers750 mm215 mm
HeightDiffers85 mm44 mm
WeightDiffers15.7 kg3.81 kg
Packaging data4 differ
Package weightDiffers22.2 kg5.53 kg
Package widthDiffers600 mm552.5 mm
Package depthDiffers165 mm406.4 mm
Package heightDiffers940 mm127 mm