Product comparison · 2 power distribution units (pdus)

APC NetShelter Rack PDU Advanced Metered, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets vs StarTech.com 20-Outlet Rackmount PDU, 1U Server Power Strip, 16x C13 + 4x C19, 8x Front and 12x Rear Outlets, NEMA L6-30P Wall Connection, 30A/240V, UL-Listed,

Add a product
  • 15specifications compared
  • 14differ
  • 1identical
  • 27known for one product only

Key differences

The APC NetShelter Rack PDU Advanced Metered, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets has 1 U more rack capacity than the StarTech.com 20-Outlet Rackmount PDU, 1U Server Power Strip, 16x C13 + 4x C19, 8x Front and 12x Rear Outlets, NEMA L6-30P Wall Connection, 30A/240V, UL-Listed, (2U vs 1U). The APC NetShelter Rack PDU Advanced Metered, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets has 30 A more maximum current than the StarTech.com 20-Outlet Rackmount PDU, 1U Server Power Strip, 16x C13 + 4x C19, 8x Front and 12x Rear Outlets, NEMA L6-30P Wall Connection, 30A/240V, UL-Listed, (60 A vs 30 A). The APC NetShelter Rack PDU Advanced Metered, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets has 399.7 mm more width than the StarTech.com 20-Outlet Rackmount PDU, 1U Server Power Strip, 16x C13 + 4x C19, 8x Front and 12x Rear Outlets, NEMA L6-30P Wall Connection, 30A/240V, UL-Listed, (443 mm vs 43.3 mm). PDU types: Metered on the APC NetShelter Rack PDU Advanced Metered, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets, Basic on the StarTech.com 20-Outlet Rackmount PDU, 1U Server Power Strip, 16x C13 + 4x C19, 8x Front and 12x Rear Outlets, NEMA L6-30P Wall Connection, 30A/240V, UL-Listed,. AC outlets quantity: 18 AC outlet(s) on the APC NetShelter Rack PDU Advanced Metered, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets, 20 AC outlet(s) on the StarTech.com 20-Outlet Rackmount PDU, 1U Server Power Strip, 16x C13 + 4x C19, 8x Front and 12x Rear Outlets, NEMA L6-30P Wall Connection, 30A/240V, UL-Listed,.

  • PDU types
    • NetShelter Rack PDU Advanced Metered, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets:Metered
    • 20-Outlet Rackmount PDU, 1U Server Power Strip, 16x C13 + 4x C19, 8x Front and 12x Rear Outlets, NEMA L6-30P Wall Connection, 30A/240V, UL-Listed,:Basic
  • Rack capacity
    • NetShelter Rack PDU Advanced Metered, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets:2U
    • 20-Outlet Rackmount PDU, 1U Server Power Strip, 16x C13 + 4x C19, 8x Front and 12x Rear Outlets, NEMA L6-30P Wall Connection, 30A/240V, UL-Listed,:1U
  • AC outlets quantity
    • NetShelter Rack PDU Advanced Metered, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets:18 AC outlet(s)
    • 20-Outlet Rackmount PDU, 1U Server Power Strip, 16x C13 + 4x C19, 8x Front and 12x Rear Outlets, NEMA L6-30P Wall Connection, 30A/240V, UL-Listed,:20 AC outlet(s)
  • Nominal input voltage
    • NetShelter Rack PDU Advanced Metered, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets:208 V
    • 20-Outlet Rackmount PDU, 1U Server Power Strip, 16x C13 + 4x C19, 8x Front and 12x Rear Outlets, NEMA L6-30P Wall Connection, 30A/240V, UL-Listed,:200-240 V
  • Maximum current
    • NetShelter Rack PDU Advanced Metered, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets:60 A
    • 20-Outlet Rackmount PDU, 1U Server Power Strip, 16x C13 + 4x C19, 8x Front and 12x Rear Outlets, NEMA L6-30P Wall Connection, 30A/240V, UL-Listed,:30 A
  • Width
    • NetShelter Rack PDU Advanced Metered, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets:443 mm
    • 20-Outlet Rackmount PDU, 1U Server Power Strip, 16x C13 + 4x C19, 8x Front and 12x Rear Outlets, NEMA L6-30P Wall Connection, 30A/240V, UL-Listed,:43.3 mm
  • Depth
    • NetShelter Rack PDU Advanced Metered, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets:750 mm
    • 20-Outlet Rackmount PDU, 1U Server Power Strip, 16x C13 + 4x C19, 8x Front and 12x Rear Outlets, NEMA L6-30P Wall Connection, 30A/240V, UL-Listed,:500 mm
  • Height
    • NetShelter Rack PDU Advanced Metered, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets:85 mm
    • 20-Outlet Rackmount PDU, 1U Server Power Strip, 16x C13 + 4x C19, 8x Front and 12x Rear Outlets, NEMA L6-30P Wall Connection, 30A/240V, UL-Listed,:95.2 mm

Side by side

Differences highlightedShow differences only (off)
Comparison of NetShelter Rack PDU Advanced Metered, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets, 2030B8H-RACK-PDU-IC
42 specifications
Design2 differ
PDU typesDiffersMeteredBasic
Rack capacityDiffers2U1U
Housing materialKnown for oneUnknown — not stated by the sourceSteel
Product colourBlackBlack
TypeKnown for oneThree-phaseUnknown — not stated by the source
MountingKnown for oneHorizontalUnknown — not stated by the source
Ports & interfaces2 differ
AC outlets quantityDiffers18 AC outlet(s)20 AC outlet(s)
AC outlet typesDiffersC13 coupler, C15 coupler, C19 coupler, C21 couplerC13 coupler, C19 coupler
Power plugKnown for oneIEC309Unknown — not stated by the source
Featuresidentical
Cable lengthKnown for oneUnknown — not stated by the source2.4 m
International Protection (IP) codeKnown for oneIP44Unknown — not stated by the source
Power2 differ
Nominal input voltageDiffers208 V200-240 V
Maximum currentDiffers60 A30 A
Nominal output voltageKnown for oneUnknown — not stated by the source200-240 V
Maximum input current per phaseKnown for oneUnknown — not stated by the source24 A
Maximum total current draw per phaseKnown for oneUnknown — not stated by the source30 A
Circuit breakerKnown for oneUnknown — not stated by the sourceYes
Output voltageKnown for one208 VUnknown — not stated by the source
Load capacityKnown for one17300 VAUnknown — not stated by the source
Weight & dimensions4 differ
WidthDiffers443 mm43.3 mm
DepthDiffers750 mm500 mm
HeightDiffers85 mm95.2 mm
WeightDiffers15.7 kg3.34 kg
Packaging contentidentical
ManualKnown for oneUnknown — not stated by the sourceYes
Number of screw nutsKnown for oneUnknown — not stated by the source4
Number of screwsKnown for oneUnknown — not stated by the source4
Rack mount kitKnown for oneUnknown — not stated by the sourceYes
Screw nuts includedKnown for oneUnknown — not stated by the sourceYes
Screws includedKnown for oneUnknown — not stated by the sourceYes
Packaging data4 differ
Package weightDiffers22.2 kg3.6 kg
Package widthDiffers600 mm511 mm
Package depthDiffers165 mm281 mm
Package heightDiffers940 mm76 mm
Logistics dataidentical
Master (outer) case widthKnown for oneUnknown — not stated by the source528 mm
Master (outer) case lengthKnown for oneUnknown — not stated by the source500 mm
Master (outer) case heightKnown for oneUnknown — not stated by the source299 mm
Products per master (outer) caseKnown for oneUnknown — not stated by the source4 pc(s)
Operational conditionsidentical
Operating temperature (T-T)Known for one-5 - 60 °CUnknown — not stated by the source
Storage temperature (T-T)Known for one-20 - 60 °CUnknown — not stated by the source
Operating relative humidity (H-H)Known for one5 - 90%Unknown — not stated by the source
Storage relative humidity (H-H)Known for one5 - 95%Unknown — not stated by the source
Non-operating altitudeKnown for one0 - 15240 mUnknown — not stated by the source

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.

More power distribution units (pdus) comparisons

All power distribution units (pdus) comparisons