Product comparison · 2 power distribution units (pdus)

APC NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets vs Vertiv PowerIT rack power distribution unit, 43.4kW, 3P+N+E (IP44) plug

Add a product
  • 20specifications compared
  • 16differ
  • 4identical
  • 27known for one product only

Key differences

The APC NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets has 37 A more maximum current than the Vertiv PowerIT rack power distribution unit, 43.4kW, 3P+N+E (IP44) plug (100 A vs 63 A). The Vertiv PowerIT rack power distribution unit, 43.4kW, 3P+N+E (IP44) plug has 37.5 mm more width than the APC NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets (96.5 mm vs 59 mm). The APC NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets has 10.8 mm more depth than the Vertiv PowerIT rack power distribution unit, 43.4kW, 3P+N+E (IP44) plug (87 mm vs 76.2 mm). PDU types: Metered on the APC NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets, Monitored on the Vertiv PowerIT rack power distribution unit, 43.4kW, 3P+N+E (IP44) plug. AC outlets quantity: 18 AC outlet(s) on the APC NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets, 36 AC outlet(s) on the Vertiv PowerIT rack power distribution unit, 43.4kW, 3P+N+E (IP44) plug.

  • PDU types
    • NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets:Metered
    • PowerIT rack power distribution unit, 43.4kW, 3P+N+E (IP44) plug:Monitored
  • AC outlets quantity
    • NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets:18 AC outlet(s)
    • PowerIT rack power distribution unit, 43.4kW, 3P+N+E (IP44) plug:36 AC outlet(s)
  • Power plug
    • NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets:IEC309
    • PowerIT rack power distribution unit, 43.4kW, 3P+N+E (IP44) plug:Type E / Type F
  • Nominal input voltage
    • NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets:415 3 phases
    • PowerIT rack power distribution unit, 43.4kW, 3P+N+E (IP44) plug:240 - 415 V
  • Maximum current
    • NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets:100 A
    • PowerIT rack power distribution unit, 43.4kW, 3P+N+E (IP44) plug:63 A
  • Width
    • NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets:59 mm
    • PowerIT rack power distribution unit, 43.4kW, 3P+N+E (IP44) plug:96.5 mm
  • Depth
    • NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets:87 mm
    • PowerIT rack power distribution unit, 43.4kW, 3P+N+E (IP44) plug:76.2 mm
  • Height
    • NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets:1750 mm
    • PowerIT rack power distribution unit, 43.4kW, 3P+N+E (IP44) plug:1682.8 mm

Side by side

Differences highlightedShow differences only (off)
Comparison of NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets, VP6U60A2
47 specifications
Design1 differ
PDU typesDiffersMeteredMonitored
TypeThree-phaseThree-phase
Rack capacity0U0U
MountingVerticalVertical
Product colourBlackBlack
UpgradeableKnown for oneYesUnknown — not stated by the source
Ports & interfaces3 differ
AC outlets quantityDiffers18 AC outlet(s)36 AC outlet(s)
Power plugDiffersIEC309Type E / Type F
AC outlet typesDiffersC13 coupler, C15 coupler, C19 coupler, C21 couplerC13 coupler, C19 coupler
Input connection typeKnown for oneIEC 309 100 AUnknown — not stated by the source
Serial ports quantityKnown for oneUnknown — not stated by the source1
USB ports quantityKnown for oneUnknown — not stated by the source1
Featuresidentical
International Protection (IP) codeKnown for oneIP67Unknown — not stated by the source
Cable lengthKnown for oneUnknown — not stated by the source3.048 m
Management features1 differ
Management platformDiffersNMC3DHCP, HTTP, HTTPS, IPv4, IPv6, LDAP, NTP, RADIUS, RSTP, SSH, SMTP, SNMP (v1/v2c/v3), Syslog, TACACS+
Power2 differ
Nominal input voltageDiffers415 3 phases240 - 415 V
Maximum currentDiffers100 A63 A
Output voltageKnown for one415 V AC 3 phasesUnknown — not stated by the source
Load capacityKnown for one69000 VAUnknown — not stated by the source
Number of phasesKnown for one3Unknown — not stated by the source
Maximum powerKnown for oneUnknown — not stated by the source43400 W
Power protection featuresKnown for oneUnknown — not stated by the sourceOver current
Certificates1 differ
Compliance certificatesDiffersRoHS, REACH, WEEEChina RoHS, Trade Agreements Act (TAA), RoHS
Waste Electrical and Electronic Equipment (WEEE) complianceKnown for oneYesUnknown — not stated by the source
CertificationKnown for oneUnknown — not stated by the sourceUL Listed, RCM Mark(EMC Only), CE Marked, UKCA Marked, Complies with IEC 62368-1
Sustainabilityidentical
Doesn't containKnown for oneSiliconeUnknown — not stated by the source
Operational conditionsidentical
Operating temperature (T-T)Known for one-5 - 60 °CUnknown — not stated by the source
Storage temperature (T-T)Known for one-20 - 60 °CUnknown — not stated by the source
Operating relative humidity (H-H)Known for one5 - 90%Unknown — not stated by the source
Storage relative humidity (H-H)Known for one5 - 95%Unknown — not stated by the source
Non-operating altitudeKnown for one0 - 15240 mUnknown — not stated by the source
Weight & dimensions4 differ
WidthDiffers59 mm96.5 mm
DepthDiffers87 mm76.2 mm
HeightDiffers1750 mm1682.8 mm
WeightDiffers18.8 kg9.98 kg
Packaging data4 differ
Package weightDiffers24.6 kg9.98 kg
Package widthDiffers350 mm279.4 mm
Package depthDiffers165 mm2209.8 mm
Package heightDiffers1980 mm177.8 mm
Technical detailsidentical
Packaging recycled materialsKnown for oneRecycled cardboardUnknown — not stated by the source
Preferred mounting positionKnown for oneno preferenceUnknown — not stated by the source
Packaging without single use plasticKnown for oneYesUnknown — not stated by the source
SCIP numberKnown for one7547f066-9302-46d9-96e9-461928dd6901Unknown — not stated by the source
Sustainable packagingKnown for oneNoUnknown — not stated by the source
Take-back systemKnown for oneNoUnknown — not stated by the source
Logistics dataidentical
Customs product code (TARIC)Known for one8537109899Unknown — not stated by the source
Country of originKnown for oneUnknown — not stated by the sourceUnited States

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.