Product comparison · 2 power distribution units (pdus)

APC NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets vs APC NetShelter Rack PDU Advanced Metered, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets

Add a product
  • 26specifications compared
  • 14differ
  • 12identical
  • 14known for one product only

Key differences

The APC NetShelter Rack PDU Advanced Metered, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets has 2 U more rack capacity than the APC NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets (2U vs 0U). The APC NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets has 40 A more maximum current than the APC NetShelter Rack PDU Advanced Metered, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets (100 A vs 60 A). The APC NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets has 51,700 VA more load capacity than the APC NetShelter Rack PDU Advanced Metered, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets (69000 VA vs 17300 VA). Mounting: Vertical on the APC NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets, Horizontal on the APC NetShelter Rack PDU Advanced Metered, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets. International Protection (IP) code: IP67 on the APC NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets, IP44 on the APC NetShelter Rack PDU Advanced Metered, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets.

  • Rack capacity
    • NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets:0U
    • NetShelter Rack PDU Advanced Metered, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets:2U
  • Mounting
    • NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets:Vertical
    • NetShelter Rack PDU Advanced Metered, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets:Horizontal
  • International Protection (IP) code
    • NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets:IP67
    • NetShelter Rack PDU Advanced Metered, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets:IP44
  • Nominal input voltage
    • NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets:415 3 phases
    • NetShelter Rack PDU Advanced Metered, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets:208 V
  • Maximum current
    • NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets:100 A
    • NetShelter Rack PDU Advanced Metered, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets:60 A
  • Output voltage
    • NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets:415 V AC 3 phases
    • NetShelter Rack PDU Advanced Metered, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets:208 V
  • Load capacity
    • NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets:69000 VA
    • NetShelter Rack PDU Advanced Metered, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets:17300 VA
  • Width
    • NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets:59 mm
    • NetShelter Rack PDU Advanced Metered, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets:443 mm

Side by side

Differences highlightedShow differences only (off)
Comparison of NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets, NetShelter Rack PDU Advanced Metered, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets
40 specifications
Design2 differ
PDU typesMeteredMetered
TypeThree-phaseThree-phase
Rack capacityDiffers0U2U
MountingDiffersVerticalHorizontal
Product colourBlackBlack
UpgradeableKnown for oneYesUnknown — not stated by the source
Ports & interfacesidentical
AC outlets quantity18 AC outlet(s)18 AC outlet(s)
Power plugIEC309IEC309
AC outlet typesC13 coupler, C15 coupler, C19 coupler, C21 couplerC13 coupler, C15 coupler, C19 coupler, C21 coupler
Input connection typeKnown for oneIEC 309 100 AUnknown — not stated by the source
Features1 differ
International Protection (IP) codeDiffersIP67IP44
Management featuresidentical
Management platformKnown for oneNMC3Unknown — not stated by the source
Power4 differ
Nominal input voltageDiffers415 3 phases208 V
Maximum currentDiffers100 A60 A
Output voltageDiffers415 V AC 3 phases208 V
Load capacityDiffers69000 VA17300 VA
Number of phasesKnown for one3Unknown — not stated by the source
Certificatesidentical
Compliance certificatesKnown for oneRoHS, REACH, WEEEUnknown — not stated by the source
Waste Electrical and Electronic Equipment (WEEE) complianceKnown for oneYesUnknown — not stated by the source
Sustainabilityidentical
Doesn't containKnown for oneSiliconeUnknown — not stated by the source
Operational conditionsidentical
Operating temperature (T-T)-5 - 60 °C-5 - 60 °C
Storage temperature (T-T)-20 - 60 °C-20 - 60 °C
Operating relative humidity (H-H)5 - 90%5 - 90%
Storage relative humidity (H-H)5 - 95%5 - 95%
Non-operating altitude0 - 15240 m0 - 15240 m
Weight & dimensions4 differ
WidthDiffers59 mm443 mm
DepthDiffers87 mm750 mm
HeightDiffers1750 mm85 mm
WeightDiffers18.8 kg15.7 kg
Packaging data3 differ
Package weightDiffers24.6 kg22.2 kg
Package widthDiffers350 mm600 mm
Package depth165 mm165 mm
Package heightDiffers1980 mm940 mm
Technical detailsidentical
Packaging recycled materialsKnown for oneRecycled cardboardUnknown — not stated by the source
Preferred mounting positionKnown for oneno preferenceUnknown — not stated by the source
Packaging without single use plasticKnown for oneYesUnknown — not stated by the source
SCIP numberKnown for one7547f066-9302-46d9-96e9-461928dd6901Unknown — not stated by the source
Sustainable packagingKnown for oneNoUnknown — not stated by the source
Take-back systemKnown for oneNoUnknown — not stated by the source
Logistics dataidentical
Customs product code (TARIC)Known for one8537109899Unknown — not stated by the source