Product comparison · 2 power distribution units (pdus)

APC NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets vs Vertiv VP0G9000 power distribution unit (PDU) 24 AC outlet(s) Black

Add a product
  • 14specifications compared
  • 11differ
  • 3identical
  • 18known for one product only

Key differences

The APC NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets has 68 A more maximum current than the Vertiv VP0G9000 power distribution unit (PDU) 24 AC outlet(s) Black (100 A vs 32 A). The Vertiv VP0G9000 power distribution unit (PDU) 24 AC outlet(s) Black has 22 V more output voltage than the APC NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets (230 V vs 208 V). The Vertiv VP0G9000 power distribution unit (PDU) 24 AC outlet(s) Black has 454 mm more width than the APC NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets (510 mm vs 56 mm). PDU types: Metered on the APC NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets, Basic on the Vertiv VP0G9000 power distribution unit (PDU) 24 AC outlet(s) Black. AC outlets quantity: 30 AC outlet(s) on the APC NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets, 24 AC outlet(s) on the Vertiv VP0G9000 power distribution unit (PDU) 24 AC outlet(s) Black.

  • PDU types
    • NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets:Metered
    • VP0G9000 power distribution unit (PDU) 24 AC outlet(s) Black:Basic
  • AC outlets quantity
    • NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets:30 AC outlet(s)
    • VP0G9000 power distribution unit (PDU) 24 AC outlet(s) Black:24 AC outlet(s)
  • Nominal input voltage
    • NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets:208 V
    • VP0G9000 power distribution unit (PDU) 24 AC outlet(s) Black:220 - 240 V
  • AC input frequency
    • NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets:50/60 Hz
    • VP0G9000 power distribution unit (PDU) 24 AC outlet(s) Black:50 - 60 Hz
  • Maximum current
    • NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets:100 A
    • VP0G9000 power distribution unit (PDU) 24 AC outlet(s) Black:32 A
  • Output voltage
    • NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets:208 V
    • VP0G9000 power distribution unit (PDU) 24 AC outlet(s) Black:230 V
  • Width
    • NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets:56 mm
    • VP0G9000 power distribution unit (PDU) 24 AC outlet(s) Black:510 mm
  • Depth
    • NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets:75 mm
    • VP0G9000 power distribution unit (PDU) 24 AC outlet(s) Black:510 mm

Side by side

Differences highlightedShow differences only (on)
Comparison of NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets, VP0G9000
32 specifications
Design1 differ
PDU typesDiffersMeteredBasic
TypeKnown for oneThree-phaseUnknown — not stated by the source
Rack capacityKnown for one0UUnknown — not stated by the source
Ports & interfaces2 differ
AC outlets quantityDiffers30 AC outlet(s)24 AC outlet(s)
AC outlet typesDiffersC15 coupler, C13 coupler, C19 coupler, C21 couplerC13 coupler, C19 coupler
Featuresidentical
International Protection (IP) codeKnown for oneIP67Unknown — not stated by the source
Cable lengthKnown for oneUnknown — not stated by the source3 m
Management featuresidentical
Management platformKnown for oneNMC3Unknown — not stated by the source
MonitoringKnown for oneUnknown — not stated by the sourceCurrent, Power, Voltage
Power4 differ
Nominal input voltageDiffers208 V220 - 240 V
AC input frequencyDiffers50/60 Hz50 - 60 Hz
Maximum currentDiffers100 A32 A
Output voltageDiffers208 V230 V
Load capacityKnown for one28800 VAUnknown — not stated by the source
Maximum powerKnown for oneUnknown — not stated by the source7300 W
Operational conditionsidentical
Operating temperature (T-T)Known for one-5 - 60 °CUnknown — not stated by the source
Storage temperature (T-T)Known for one-20 - 60 °CUnknown — not stated by the source
Operating relative humidity (H-H)Known for one5 - 90%Unknown — not stated by the source
Storage relative humidity (H-H)Known for one5 - 95%Unknown — not stated by the source
Non-operating altitudeKnown for one0 - 15240 mUnknown — not stated by the source
Weight & dimensions4 differ
WidthDiffers56 mm510 mm
DepthDiffers75 mm510 mm
HeightDiffers1900 mm1683 mm
WeightDiffers14 kg6.35 kg
Packaging dataidentical
Package weightKnown for one19.8 kgUnknown — not stated by the source
Package widthKnown for one350 mmUnknown — not stated by the source
Package depthKnown for one165 mmUnknown — not stated by the source
Package heightKnown for one2110 mmUnknown — not stated by the source
Certificatesidentical
Compliance certificatesKnown for oneUnknown — not stated by the sourceRoHS

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.