Product comparison · 2 power distribution units (pdus)

APC NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets vs Vertiv Geist MN05MGW1-24CF18-8PS15D0A10-S power distribution unit (PDU) 24 AC outlet(s) 0U Black

Add a product
  • 17specifications compared
  • 9differ
  • 8identical
  • 19known for one product only

Key differences

The APC NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets has 28,592 VA more load capacity than the Vertiv Geist MN05MGW1-24CF18-8PS15D0A10-S power distribution unit (PDU) 24 AC outlet(s) 0U Black (28800 VA vs 208 VA). The Vertiv Geist MN05MGW1-24CF18-8PS15D0A10-S power distribution unit (PDU) 24 AC outlet(s) 0U Black has 41 mm more width than the APC NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets (97 mm vs 56 mm). The Vertiv Geist MN05MGW1-24CF18-8PS15D0A10-S power distribution unit (PDU) 24 AC outlet(s) 0U Black has 1 mm more depth than the APC NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets (76 mm vs 75 mm). PDU types: Metered on the APC NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets, Monitored on the Vertiv Geist MN05MGW1-24CF18-8PS15D0A10-S power distribution unit (PDU) 24 AC outlet(s) 0U Black. AC outlets quantity: 30 AC outlet(s) on the APC NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets, 24 AC outlet(s) on the Vertiv Geist MN05MGW1-24CF18-8PS15D0A10-S power distribution unit (PDU) 24 AC outlet(s) 0U Black.

  • PDU types
    • NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets:Metered
    • Geist MN05MGW1-24CF18-8PS15D0A10-S power distribution unit (PDU) 24 AC outlet(s) 0U Black:Monitored
  • AC outlets quantity
    • NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets:30 AC outlet(s)
    • Geist MN05MGW1-24CF18-8PS15D0A10-S power distribution unit (PDU) 24 AC outlet(s) 0U Black:24 AC outlet(s)
  • Load capacity
    • NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets:28800 VA
    • Geist MN05MGW1-24CF18-8PS15D0A10-S power distribution unit (PDU) 24 AC outlet(s) 0U Black:208 VA
  • Operating temperature (T-T)
    • NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets:-5 - 60 °C
    • Geist MN05MGW1-24CF18-8PS15D0A10-S power distribution unit (PDU) 24 AC outlet(s) 0U Black:10 - 45 °C
  • Width
    • NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets:56 mm
    • Geist MN05MGW1-24CF18-8PS15D0A10-S power distribution unit (PDU) 24 AC outlet(s) 0U Black:97 mm
  • Depth
    • NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets:75 mm
    • Geist MN05MGW1-24CF18-8PS15D0A10-S power distribution unit (PDU) 24 AC outlet(s) 0U Black:76 mm
  • Height
    • NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets:1900 mm
    • Geist MN05MGW1-24CF18-8PS15D0A10-S power distribution unit (PDU) 24 AC outlet(s) 0U Black:1683 mm
  • Weight
    • NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets:14 kg
    • Geist MN05MGW1-24CF18-8PS15D0A10-S power distribution unit (PDU) 24 AC outlet(s) 0U Black:8.6 kg

Side by side

Differences highlightedShow differences only (off)
Comparison of NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets, MN05MGW1-24CF18-8PS15D0A10-S
36 specifications
Design1 differ
PDU typesDiffersMeteredMonitored
TypeThree-phaseThree-phase
Rack capacity0U0U
MountingVerticalVertical
Product colourBlackBlack
DisplayKnown for oneUnknown — not stated by the sourceLCD
Ports & interfaces2 differ
AC outlets quantityDiffers30 AC outlet(s)24 AC outlet(s)
Power plugIEC 60309IEC 60309
AC outlet typesDiffersC15 coupler, C13 coupler, C19 coupler, C21 couplerC13 coupler, C19 coupler
Serial ports quantityKnown for oneUnknown — not stated by the source1
Ethernet LAN (RJ-45) portsKnown for oneUnknown — not stated by the source1
USB ports quantityKnown for oneUnknown — not stated by the source1
Featuresidentical
International Protection (IP) codeKnown for oneIP67Unknown — not stated by the source
Reset buttonKnown for oneUnknown — not stated by the sourceYes
LED indicatorsKnown for oneUnknown — not stated by the sourceYes
Cable lengthKnown for oneUnknown — not stated by the source3.05 m
Management featuresidentical
Management platformKnown for oneNMC3Unknown — not stated by the source
Power1 differ
Nominal input voltage208 V208 V
AC input frequency50/60 Hz50/60 Hz
Maximum current100 A100 A
Output voltageKnown for one208 VUnknown — not stated by the source
Load capacityDiffers28800 VA208 VA
Operational conditions1 differ
Operating temperature (T-T)Differs-5 - 60 °C10 - 45 °C
Storage temperature (T-T)Known for one-20 - 60 °CUnknown — not stated by the source
Operating relative humidity (H-H)Known for one5 - 90%Unknown — not stated by the source
Storage relative humidity (H-H)Known for one5 - 95%Unknown — not stated by the source
Non-operating altitudeKnown for one0 - 15240 mUnknown — not stated by the source
Weight & dimensions4 differ
WidthDiffers56 mm97 mm
DepthDiffers75 mm76 mm
HeightDiffers1900 mm1683 mm
WeightDiffers14 kg8.6 kg
Packaging dataidentical
Package weightKnown for one19.8 kgUnknown — not stated by the source
Package widthKnown for one350 mmUnknown — not stated by the source
Package depthKnown for one165 mmUnknown — not stated by the source
Package heightKnown for one2110 mmUnknown — not stated by the source
Certificatesidentical
CertificationKnown for oneUnknown — not stated by the sourceUL & c-UL Listed 62368-1 RoHS Compliant FCC Part 15 Class A Conformance

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.