Product comparison · 2 power distribution units (pdus)

APC NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets vs Vertiv Geist CI30000L power distribution unit (PDU) 25 AC outlet(s) 0U Black

Add a product
  • 14specifications compared
  • 11differ
  • 3identical
  • 19known for one product only

Key differences

The Vertiv Geist CI30000L power distribution unit (PDU) 25 AC outlet(s) 0U Black has 22 V more nominal input voltage than the APC NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets (230 V vs 208 V). The APC NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets has 68 A more maximum current than the Vertiv Geist CI30000L power distribution unit (PDU) 25 AC outlet(s) 0U Black (100 A vs 32 A). The Vertiv Geist CI30000L power distribution unit (PDU) 25 AC outlet(s) 0U Black has 22 V more output voltage than the APC NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets (230 V vs 208 V). PDU types: Metered on the APC NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets, Monitored on the Vertiv Geist CI30000L power distribution unit (PDU) 25 AC outlet(s) 0U Black. AC outlets quantity: 30 AC outlet(s) on the APC NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets, 25 AC outlet(s) on the Vertiv Geist CI30000L power distribution unit (PDU) 25 AC outlet(s) 0U Black.

  • PDU types
    • NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets:Metered
    • Geist CI30000L power distribution unit (PDU) 25 AC outlet(s) 0U Black:Monitored
  • AC outlets quantity
    • NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets:30 AC outlet(s)
    • Geist CI30000L power distribution unit (PDU) 25 AC outlet(s) 0U Black:25 AC outlet(s)
  • Nominal input voltage
    • NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets:208 V
    • Geist CI30000L power distribution unit (PDU) 25 AC outlet(s) 0U Black:230 V
  • AC input frequency
    • NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets:50/60 Hz
    • Geist CI30000L power distribution unit (PDU) 25 AC outlet(s) 0U Black:50 - 60 Hz
  • Maximum current
    • NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets:100 A
    • Geist CI30000L power distribution unit (PDU) 25 AC outlet(s) 0U Black:32 A
  • Output voltage
    • NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets:208 V
    • Geist CI30000L power distribution unit (PDU) 25 AC outlet(s) 0U Black:230 V
  • Load capacity
    • NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets:28800 VA
    • Geist CI30000L power distribution unit (PDU) 25 AC outlet(s) 0U Black:7.3 VA
  • Width
    • NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets:56 mm
    • Geist CI30000L power distribution unit (PDU) 25 AC outlet(s) 0U Black:51 mm

Side by side

Differences highlightedShow differences only (off)
Comparison of NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets, CI30000L
33 specifications
Design1 differ
PDU typesDiffersMeteredMonitored
TypeKnown for oneThree-phaseUnknown — not stated by the source
Rack capacity0U0U
MountingVerticalVertical
Product colourBlackBlack
DisplayKnown for oneUnknown — not stated by the sourceLED
Ports & interfaces2 differ
AC outlets quantityDiffers30 AC outlet(s)25 AC outlet(s)
Power plugKnown for oneIEC 60309Unknown — not stated by the source
AC outlet typesDiffersC15 coupler, C13 coupler, C19 coupler, C21 couplerC13 coupler, C19 coupler
Ethernet LAN (RJ-45) portsKnown for oneUnknown — not stated by the source2
Featuresidentical
International Protection (IP) codeKnown for oneIP67Unknown — not stated by the source
Daisy chainKnown for oneUnknown — not stated by the sourceYes
Reset buttonKnown for oneUnknown — not stated by the sourceYes
Management featuresidentical
Management platformKnown for oneNMC3Unknown — not stated by the source
Power5 differ
Nominal input voltageDiffers208 V230 V
AC input frequencyDiffers50/60 Hz50 - 60 Hz
Maximum currentDiffers100 A32 A
Output voltageDiffers208 V230 V
Load capacityDiffers28800 VA7.3 VA
Operational conditionsidentical
Operating temperature (T-T)Known for one-5 - 60 °CUnknown — not stated by the source
Storage temperature (T-T)Known for one-20 - 60 °CUnknown — not stated by the source
Operating relative humidity (H-H)Known for one5 - 90%Unknown — not stated by the source
Storage relative humidity (H-H)Known for one5 - 95%Unknown — not stated by the source
Non-operating altitudeKnown for one0 - 15240 mUnknown — not stated by the source
Weight & dimensions3 differ
WidthDiffers56 mm51 mm
DepthDiffers75 mm51 mm
HeightDiffers1900 mm1683 mm
WeightKnown for one14 kgUnknown — not stated by the source
Packaging dataidentical
Package weightKnown for one19.8 kgUnknown — not stated by the source
Package widthKnown for one350 mmUnknown — not stated by the source
Package depthKnown for one165 mmUnknown — not stated by the source
Package heightKnown for one2110 mmUnknown — not stated by the source
Certificatesidentical
Compliance certificatesKnown for oneUnknown — not stated by the sourceCE, China RoHS, RoHS

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.

More power distribution units (pdus) comparisons