Product comparison · 2 power distribution units (pdus)

APC NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets vs Lanview LVR-2MSCH-SCH-C13-4 power distribution unit (PDU) 4 AC outlet(s) 1U Black

Add a product
  • 18specifications compared
  • 17differ
  • 1identical
  • 15known for one product only

Key differences

The Lanview LVR-2MSCH-SCH-C13-4 power distribution unit (PDU) 4 AC outlet(s) 1U Black has 1 U more rack capacity than the APC NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets (1U vs 0U). The Lanview LVR-2MSCH-SCH-C13-4 power distribution unit (PDU) 4 AC outlet(s) 1U Black has 22 V more nominal input voltage than the APC NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets (230 V vs 208 V). The APC NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets has 84 A more maximum current than the Lanview LVR-2MSCH-SCH-C13-4 power distribution unit (PDU) 4 AC outlet(s) 1U Black (100 A vs 16 A). PDU types: Metered on the APC NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets, Basic on the Lanview LVR-2MSCH-SCH-C13-4 power distribution unit (PDU) 4 AC outlet(s) 1U Black. Type: Three-phase on the APC NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets, Single-phase on the Lanview LVR-2MSCH-SCH-C13-4 power distribution unit (PDU) 4 AC outlet(s) 1U Black.

  • PDU types
    • NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets:Metered
    • LVR-2MSCH-SCH-C13-4 power distribution unit (PDU) 4 AC outlet(s) 1U Black:Basic
  • Type
    • NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets:Three-phase
    • LVR-2MSCH-SCH-C13-4 power distribution unit (PDU) 4 AC outlet(s) 1U Black:Single-phase
  • Rack capacity
    • NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets:0U
    • LVR-2MSCH-SCH-C13-4 power distribution unit (PDU) 4 AC outlet(s) 1U Black:1U
  • Mounting
    • NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets:Vertical
    • LVR-2MSCH-SCH-C13-4 power distribution unit (PDU) 4 AC outlet(s) 1U Black:Horizontal
  • AC outlets quantity
    • NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets:30 AC outlet(s)
    • LVR-2MSCH-SCH-C13-4 power distribution unit (PDU) 4 AC outlet(s) 1U Black:4 AC outlet(s)
  • Power plug
    • NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets:IEC 60309
    • LVR-2MSCH-SCH-C13-4 power distribution unit (PDU) 4 AC outlet(s) 1U Black:C14 coupler
  • Nominal input voltage
    • NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets:208 V
    • LVR-2MSCH-SCH-C13-4 power distribution unit (PDU) 4 AC outlet(s) 1U Black:230 V
  • Maximum current
    • NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets:100 A
    • LVR-2MSCH-SCH-C13-4 power distribution unit (PDU) 4 AC outlet(s) 1U Black:16 A

Side by side

Differences highlightedShow differences only (off)
Comparison of NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets, LVR-2MSCH-SCH-C13-4
33 specifications
Design4 differ
PDU typesDiffersMeteredBasic
TypeDiffersThree-phaseSingle-phase
Rack capacityDiffers0U1U
MountingDiffersVerticalHorizontal
Product colourBlackBlack
Rack mountingKnown for oneUnknown — not stated by the sourceYes
Ports & interfaces3 differ
AC outlets quantityDiffers30 AC outlet(s)4 AC outlet(s)
Power plugDiffersIEC 60309C14 coupler
AC outlet typesDiffersC15 coupler, C13 coupler, C19 coupler, C21 couplerType F
Featuresidentical
International Protection (IP) codeKnown for oneIP67Unknown — not stated by the source
LED indicatorsKnown for oneUnknown — not stated by the sourcePower
Cable lengthKnown for oneUnknown — not stated by the source2 m
Management featuresidentical
Management platformKnown for oneNMC3Unknown — not stated by the source
Power2 differ
Nominal input voltageDiffers208 V230 V
AC input frequencyKnown for one50/60 HzUnknown — not stated by the source
Maximum currentDiffers100 A16 A
Output voltageKnown for one208 VUnknown — not stated by the source
Load capacityKnown for one28800 VAUnknown — not stated by the source
Nominal output voltageKnown for oneUnknown — not stated by the source230 V
Operational conditionsidentical
Operating temperature (T-T)Known for one-5 - 60 °CUnknown — not stated by the source
Storage temperature (T-T)Known for one-20 - 60 °CUnknown — not stated by the source
Operating relative humidity (H-H)Known for one5 - 90%Unknown — not stated by the source
Storage relative humidity (H-H)Known for one5 - 95%Unknown — not stated by the source
Non-operating altitudeKnown for one0 - 15240 mUnknown — not stated by the source
Weight & dimensions4 differ
WidthDiffers56 mm500 mm
DepthDiffers75 mm80 mm
HeightDiffers1900 mm60 mm
WeightDiffers14 kg1.1 kg
Size (imperial)Known for oneUnknown — not stated by the source25.4 cm (10")
Packaging data4 differ
Package weightDiffers19.8 kg1.2 kg
Package widthDiffers350 mm500 mm
Package depthDiffers165 mm80 mm
Package heightDiffers2110 mm60 mm

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.

More power distribution units (pdus) comparisons

All power distribution units (pdus) comparisons