Product comparison · 2 power distribution units (pdus)

APC NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets vs Intellinet 19" 1U PDU 7-way UK, Overload Protection, Rackmount, Power Distribution Unit, UK 3-pin outlets, 3m power cord, output

Add a product
  • 19specifications compared
  • 18differ
  • 1identical
  • 17known for one product only

Key differences

The Intellinet 19" 1U PDU 7-way UK, Overload Protection, Rackmount, Power Distribution Unit, UK 3-pin outlets, 3m power cord, output has 1 U more rack capacity than the APC NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets (1U vs 0U). The APC NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets has 87 A more maximum current than the Intellinet 19" 1U PDU 7-way UK, Overload Protection, Rackmount, Power Distribution Unit, UK 3-pin outlets, 3m power cord, output (100 A vs 13 A). The Intellinet 19" 1U PDU 7-way UK, Overload Protection, Rackmount, Power Distribution Unit, UK 3-pin outlets, 3m power cord, output has 426.6 mm more width than the APC NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets (482.6 mm vs 56 mm). PDU types: Metered on the APC NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets, Basic on the Intellinet 19" 1U PDU 7-way UK, Overload Protection, Rackmount, Power Distribution Unit, UK 3-pin outlets, 3m power cord, output. Type: Three-phase on the APC NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets, Single-phase on the Intellinet 19" 1U PDU 7-way UK, Overload Protection, Rackmount, Power Distribution Unit, UK 3-pin outlets, 3m power cord, output.

  • PDU types
    • NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets:Metered
    • 19" 1U PDU 7-way UK, Overload Protection, Rackmount, Power Distribution Unit, UK 3-pin outlets, 3m power cord, output:Basic
  • Type
    • NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets:Three-phase
    • 19" 1U PDU 7-way UK, Overload Protection, Rackmount, Power Distribution Unit, UK 3-pin outlets, 3m power cord, output:Single-phase
  • Rack capacity
    • NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets:0U
    • 19" 1U PDU 7-way UK, Overload Protection, Rackmount, Power Distribution Unit, UK 3-pin outlets, 3m power cord, output:1U
  • Mounting
    • NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets:Vertical
    • 19" 1U PDU 7-way UK, Overload Protection, Rackmount, Power Distribution Unit, UK 3-pin outlets, 3m power cord, output:Horizontal
  • Product colour
    • NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets:Black
    • 19" 1U PDU 7-way UK, Overload Protection, Rackmount, Power Distribution Unit, UK 3-pin outlets, 3m power cord, output:Black, White
  • AC outlets quantity
    • NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets:30 AC outlet(s)
    • 19" 1U PDU 7-way UK, Overload Protection, Rackmount, Power Distribution Unit, UK 3-pin outlets, 3m power cord, output:8 AC outlet(s)
  • Power plug
    • NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets:IEC 60309
    • 19" 1U PDU 7-way UK, Overload Protection, Rackmount, Power Distribution Unit, UK 3-pin outlets, 3m power cord, output:BS 1363
  • Nominal input voltage
    • NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets:208 V
    • 19" 1U PDU 7-way UK, Overload Protection, Rackmount, Power Distribution Unit, UK 3-pin outlets, 3m power cord, output:220 - 250 V

Side by side

Differences highlightedShow differences only (off)
Comparison of NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets, 715324
36 specifications
Design5 differ
PDU typesDiffersMeteredBasic
TypeDiffersThree-phaseSingle-phase
Rack capacityDiffers0U1U
MountingDiffersVerticalHorizontal
Product colourDiffersBlackBlack, White
Housing materialKnown for oneUnknown — not stated by the sourceAluminium
On/off switchKnown for oneUnknown — not stated by the sourceNo
Ports & interfaces3 differ
AC outlets quantityDiffers30 AC outlet(s)8 AC outlet(s)
Power plugDiffersIEC 60309BS 1363
AC outlet typesDiffersC15 coupler, C13 coupler, C19 coupler, C21 couplerBS 1363
Featuresidentical
International Protection (IP) codeKnown for oneIP67Unknown — not stated by the source
Reset buttonKnown for oneUnknown — not stated by the sourceYes
Cable lengthKnown for oneUnknown — not stated by the source3 m
Management featuresidentical
Management platformKnown for oneNMC3Unknown — not stated by the source
Power2 differ
Nominal input voltageDiffers208 V220 - 250 V
AC input frequency50/60 Hz50/60 Hz
Maximum currentDiffers100 A13 A
Output voltageKnown for one208 VUnknown — not stated by the source
Load capacityKnown for one28800 VAUnknown — not stated by the source
Maximum powerKnown for oneUnknown — not stated by the source3250 W
Power protection featuresKnown for oneUnknown — not stated by the sourceOverload
Operational conditionsidentical
Operating temperature (T-T)Known for one-5 - 60 °CUnknown — not stated by the source
Storage temperature (T-T)Known for one-20 - 60 °CUnknown — not stated by the source
Operating relative humidity (H-H)Known for one5 - 90%Unknown — not stated by the source
Storage relative humidity (H-H)Known for one5 - 95%Unknown — not stated by the source
Non-operating altitudeKnown for one0 - 15240 mUnknown — not stated by the source
Weight & dimensions4 differ
WidthDiffers56 mm482.6 mm
DepthDiffers75 mm44.5 mm
HeightDiffers1900 mm44.5 mm
WeightDiffers14 kg945 g
Size (imperial)Known for oneUnknown — not stated by the source48.3 cm (19")
Packaging data4 differ
Package weightDiffers19.8 kg1.02 kg
Package widthDiffers350 mm510 mm
Package depthDiffers165 mm100 mm
Package heightDiffers2110 mm60 mm
Certificatesidentical
Compliance certificatesKnown for oneUnknown — not stated by the sourceUKCA, CE, RoHS, REACH

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.