Product comparison · 2 power distribution units (pdus)

APC NetShelter Rack PDU Advanced Gen 2, Switched, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlet vs APC NetShelter Rack PDU Advanced Gen 2, Switched Metered Outlet,3Phase, 43.5kW 400V 63A or 34.6kW 415V 60A, 560P6, 42 Outlet

Add a product
  • 37specifications compared
  • 6differ
  • 31identical
  • 1known for one product only

Key differences

The APC NetShelter Rack PDU Advanced Gen 2, Switched Metered Outlet,3Phase, 43.5kW 400V 63A or 34.6kW 415V 60A, 560P6, 42 Outlet has 10 V more output voltage than the APC NetShelter Rack PDU Advanced Gen 2, Switched, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlet (240 V vs 230 V). The APC NetShelter Rack PDU Advanced Gen 2, Switched Metered Outlet,3Phase, 43.5kW 400V 63A or 34.6kW 415V 60A, 560P6, 42 Outlet has 2 more phases than the APC NetShelter Rack PDU Advanced Gen 2, Switched, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlet (3 vs 1). The APC NetShelter Rack PDU Advanced Gen 2, Switched Metered Outlet,3Phase, 43.5kW 400V 63A or 34.6kW 415V 60A, 560P6, 42 Outlet has 336 mm more height than the APC NetShelter Rack PDU Advanced Gen 2, Switched, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlet (1826 mm vs 1490 mm). Input connection type: IEC 60309 32 A 2P + PE on the APC NetShelter Rack PDU Advanced Gen 2, Switched, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlet, IEC 60309 60 A 3P + N + PE on the APC NetShelter Rack PDU Advanced Gen 2, Switched Metered Outlet,3Phase, 43.5kW 400V 63A or 34.6kW 415V 60A, 560P6, 42 Outlet. Nominal input voltage: 230 1 phase on the APC NetShelter Rack PDU Advanced Gen 2, Switched, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlet, 415 3 phases on the APC NetShelter Rack PDU Advanced Gen 2, Switched Metered Outlet,3Phase, 43.5kW 400V 63A or 34.6kW 415V 60A, 560P6, 42 Outlet.

  • Input connection type
    • NetShelter Rack PDU Advanced Gen 2, Switched, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlet:IEC 60309 32 A 2P + PE
    • NetShelter Rack PDU Advanced Gen 2, Switched Metered Outlet,3Phase, 43.5kW 400V 63A or 34.6kW 415V 60A, 560P6, 42 Outlet:IEC 60309 60 A 3P + N + PE
  • Nominal input voltage
    • NetShelter Rack PDU Advanced Gen 2, Switched, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlet:230 1 phase
    • NetShelter Rack PDU Advanced Gen 2, Switched Metered Outlet,3Phase, 43.5kW 400V 63A or 34.6kW 415V 60A, 560P6, 42 Outlet:415 3 phases
  • Output voltage
    • NetShelter Rack PDU Advanced Gen 2, Switched, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlet:230 V
    • NetShelter Rack PDU Advanced Gen 2, Switched Metered Outlet,3Phase, 43.5kW 400V 63A or 34.6kW 415V 60A, 560P6, 42 Outlet:240 V
  • Number of phases
    • NetShelter Rack PDU Advanced Gen 2, Switched, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlet:1
    • NetShelter Rack PDU Advanced Gen 2, Switched Metered Outlet,3Phase, 43.5kW 400V 63A or 34.6kW 415V 60A, 560P6, 42 Outlet:3
  • Height
    • NetShelter Rack PDU Advanced Gen 2, Switched, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlet:1490 mm
    • NetShelter Rack PDU Advanced Gen 2, Switched Metered Outlet,3Phase, 43.5kW 400V 63A or 34.6kW 415V 60A, 560P6, 42 Outlet:1826 mm
  • Weight
    • NetShelter Rack PDU Advanced Gen 2, Switched, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlet:7.4 kg
    • NetShelter Rack PDU Advanced Gen 2, Switched Metered Outlet,3Phase, 43.5kW 400V 63A or 34.6kW 415V 60A, 560P6, 42 Outlet:12.7 kg

Side by side

Differences highlightedShow differences only (on)
Comparison of NetShelter Rack PDU Advanced Gen 2, Switched, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlet, NetShelter Rack PDU Advanced Gen 2, Switched Metered Outlet,3Phase, 43.5kW 400V 63A or 34.6kW 415V 60A, 560P6, 42 Outlet
38 specifications
Ports & interfaces1 differ
Input connection typeDiffersIEC 60309 32 A 2P + PEIEC 60309 60 A 3P + N + PE
Power3 differ
Nominal input voltageDiffers230 1 phase415 3 phases
Output voltageDiffers230 V240 V
Number of phasesDiffers13
Certificatesidentical
CertificationKnown for oneUKCAUnknown — not stated by the source
Weight & dimensions2 differ
HeightDiffers1490 mm1826 mm
WeightDiffers7.4 kg12.7 kg

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.