Product comparison · 2 power distribution units (pdus)

APC NetShelter Rack PDU Advanced Gen 2, Metered Outlet, 3Phase, 22.1kW 400V 32A or 17.3kW 415V 30A, 530P6, 48 Outlet vs APC NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets

Add a product
  • 29specifications compared
  • 16differ
  • 13identical
  • 19known for one product only

Key differences

The APC NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets has 40 A more maximum current than the APC NetShelter Rack PDU Advanced Gen 2, Metered Outlet, 3Phase, 22.1kW 400V 32A or 17.3kW 415V 30A, 530P6, 48 Outlet (100 A vs 60 A). The APC NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets has 34,400 VA more load capacity than the APC NetShelter Rack PDU Advanced Gen 2, Metered Outlet, 3Phase, 22.1kW 400V 32A or 17.3kW 415V 30A, 530P6, 48 Outlet (69000 VA vs 34600 VA). The APC NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets has 3 mm more width than the APC NetShelter Rack PDU Advanced Gen 2, Metered Outlet, 3Phase, 22.1kW 400V 32A or 17.3kW 415V 30A, 530P6, 48 Outlet (59 mm vs 56 mm). Only the APC NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets has packaging without single use plastic. AC outlets quantity: 42 AC outlet(s) on the APC NetShelter Rack PDU Advanced Gen 2, Metered Outlet, 3Phase, 22.1kW 400V 32A or 17.3kW 415V 30A, 530P6, 48 Outlet, 18 AC outlet(s) on the APC NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets.

  • AC outlets quantity
    • NetShelter Rack PDU Advanced Gen 2, Metered Outlet, 3Phase, 22.1kW 400V 32A or 17.3kW 415V 30A, 530P6, 48 Outlet:42 AC outlet(s)
    • NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets:18 AC outlet(s)
  • Input connection type
    • NetShelter Rack PDU Advanced Gen 2, Metered Outlet, 3Phase, 22.1kW 400V 32A or 17.3kW 415V 30A, 530P6, 48 Outlet:IEC 60309 30 A 3P + N + PE
    • NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets:IEC 309 100 A
  • Nominal input voltage
    • NetShelter Rack PDU Advanced Gen 2, Metered Outlet, 3Phase, 22.1kW 400V 32A or 17.3kW 415V 30A, 530P6, 48 Outlet:415 3 phases; 400 3 phases
    • NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets:415 3 phases
  • Maximum current
    • NetShelter Rack PDU Advanced Gen 2, Metered Outlet, 3Phase, 22.1kW 400V 32A or 17.3kW 415V 30A, 530P6, 48 Outlet:60 A
    • NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets:100 A
  • Output voltage
    • NetShelter Rack PDU Advanced Gen 2, Metered Outlet, 3Phase, 22.1kW 400V 32A or 17.3kW 415V 30A, 530P6, 48 Outlet:240 V
    • NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets:415 V AC 3 phases
  • Load capacity
    • NetShelter Rack PDU Advanced Gen 2, Metered Outlet, 3Phase, 22.1kW 400V 32A or 17.3kW 415V 30A, 530P6, 48 Outlet:34600 VA
    • NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets:69000 VA
  • Width
    • NetShelter Rack PDU Advanced Gen 2, Metered Outlet, 3Phase, 22.1kW 400V 32A or 17.3kW 415V 30A, 530P6, 48 Outlet:56 mm
    • NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets:59 mm
  • Depth
    • NetShelter Rack PDU Advanced Gen 2, Metered Outlet, 3Phase, 22.1kW 400V 32A or 17.3kW 415V 30A, 530P6, 48 Outlet:75 mm
    • NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets:87 mm

Side by side

Differences highlightedShow differences only (off)
Comparison of NetShelter Rack PDU Advanced Gen 2, Metered Outlet, 3Phase, 22.1kW 400V 32A or 17.3kW 415V 30A, 530P6, 48 Outlet, NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets
48 specifications
Designidentical
PDU typesMeteredMetered
TypeThree-phaseThree-phase
Rack capacity0U0U
MountingKnown for oneUnknown — not stated by the sourceVertical
Product colourBlackBlack
UpgradeableKnown for oneUnknown — not stated by the sourceYes
Ports & interfaces2 differ
AC outlets quantityDiffers42 AC outlet(s)18 AC outlet(s)
Power plugKnown for oneUnknown — not stated by the sourceIEC309
AC outlet typesC13 coupler, C15 coupler, C19 coupler, C21 couplerC13 coupler, C15 coupler, C19 coupler, C21 coupler
Input connection typeDiffersIEC 60309 30 A 3P + N + PEIEC 309 100 A
Ethernet LAN (RJ-45) portsKnown for one5Unknown — not stated by the source
USB ports quantityKnown for one1Unknown — not stated by the source
Featuresidentical
International Protection (IP) codeKnown for oneUnknown — not stated by the sourceIP67
Cable lengthKnown for one3 mUnknown — not stated by the source
Management featuresidentical
Management platformNMC3NMC3
Power4 differ
Nominal input voltageDiffers415 3 phases; 400 3 phases415 3 phases
Maximum currentDiffers60 A100 A
Output voltageDiffers240 V415 V AC 3 phases
Load capacityDiffers34600 VA69000 VA
Number of phases33
AC input frequencyKnown for one50/60 HzUnknown — not stated by the source
Nominal output voltageKnown for one400 VUnknown — not stated by the source
Battery replacement accessibilityKnown for oneNon-removableUnknown — not stated by the source
Certificatesidentical
Compliance certificatesRoHS, REACH, WEEERoHS, REACH, WEEE
Waste Electrical and Electronic Equipment (WEEE) complianceYesYes
CertificationKnown for oneUKCAUnknown — not stated by the source
Sustainabilityidentical
Doesn't containKnown for oneUnknown — not stated by the sourceSilicone
Operational conditionsidentical
Operating temperature (T-T)Known for oneUnknown — not stated by the source-5 - 60 °C
Storage temperature (T-T)Known for oneUnknown — not stated by the source-20 - 60 °C
Operating relative humidity (H-H)Known for oneUnknown — not stated by the source5 - 90%
Storage relative humidity (H-H)Known for oneUnknown — not stated by the source5 - 95%
Non-operating altitudeKnown for oneUnknown — not stated by the source0 - 15240 m
Weight & dimensions4 differ
WidthDiffers56 mm59 mm
DepthDiffers75 mm87 mm
HeightDiffers1780 mm1750 mm
WeightDiffers9.6 kg18.8 kg
Packaging data4 differ
Package weightDiffers17 kg24.6 kg
Package widthDiffers132 mm350 mm
Package depthDiffers262 mm165 mm
Package heightDiffers2110 mm1980 mm
Technical details2 differ
Packaging recycled materialsKnown for oneUnknown — not stated by the sourceRecycled cardboard
Preferred mounting positionno preferenceno preference
Packaging without single use plasticDiffersNoYes
SCIP numberDiffers31346aed-552c-4a16-81d9-e683a383b6da7547f066-9302-46d9-96e9-461928dd6901
Sustainable packagingNoNo
Take-back systemNoNo
Removable batteryKnown for oneNoUnknown — not stated by the source
Logistics dataidentical
Customs product code (TARIC)85371098998537109899

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.