Product comparison · 2 power distribution units (pdus)

APC NetShelter Rack PDU Advanced Gen 2, Metered, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlets vs ATEN 1U 16A 8 Outlet Switched + Metered PDU + Free Eco PDU Manager Software

Add a product
  • 20specifications compared
  • 17differ
  • 3identical
  • 34known for one product only

Key differences

The ATEN 1U 16A 8 Outlet Switched + Metered PDU + Free Eco PDU Manager Software has 1 U more rack capacity than the APC NetShelter Rack PDU Advanced Gen 2, Metered, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlets (1U vs 0U). The APC NetShelter Rack PDU Advanced Gen 2, Metered, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlets has 16 A more maximum current than the ATEN 1U 16A 8 Outlet Switched + Metered PDU + Free Eco PDU Manager Software (32 A vs 16 A). The APC NetShelter Rack PDU Advanced Gen 2, Metered, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlets has 3,720 VA more load capacity than the ATEN 1U 16A 8 Outlet Switched + Metered PDU + Free Eco PDU Manager Software (7400 VA vs 3680 VA). PDU types: Metered on the APC NetShelter Rack PDU Advanced Gen 2, Metered, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlets, Metered, Switched on the ATEN 1U 16A 8 Outlet Switched + Metered PDU + Free Eco PDU Manager Software. AC outlets quantity: 40 AC outlet(s) on the APC NetShelter Rack PDU Advanced Gen 2, Metered, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlets, 8 AC outlet(s) on the ATEN 1U 16A 8 Outlet Switched + Metered PDU + Free Eco PDU Manager Software.

  • PDU types
    • NetShelter Rack PDU Advanced Gen 2, Metered, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlets:Metered
    • 1U 16A 8 Outlet Switched + Metered PDU + Free Eco PDU Manager Software:Metered, Switched
  • Rack capacity
    • NetShelter Rack PDU Advanced Gen 2, Metered, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlets:0U
    • 1U 16A 8 Outlet Switched + Metered PDU + Free Eco PDU Manager Software:1U
  • AC outlets quantity
    • NetShelter Rack PDU Advanced Gen 2, Metered, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlets:40 AC outlet(s)
    • 1U 16A 8 Outlet Switched + Metered PDU + Free Eco PDU Manager Software:8 AC outlet(s)
  • Nominal input voltage
    • NetShelter Rack PDU Advanced Gen 2, Metered, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlets:230 1 phase
    • 1U 16A 8 Outlet Switched + Metered PDU + Free Eco PDU Manager Software:100 - 240 V
  • AC input frequency
    • NetShelter Rack PDU Advanced Gen 2, Metered, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlets:50/60 Hz
    • 1U 16A 8 Outlet Switched + Metered PDU + Free Eco PDU Manager Software:50 - 60 Hz
  • Maximum current
    • NetShelter Rack PDU Advanced Gen 2, Metered, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlets:32 A
    • 1U 16A 8 Outlet Switched + Metered PDU + Free Eco PDU Manager Software:16 A
  • Nominal output voltage
    • NetShelter Rack PDU Advanced Gen 2, Metered, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlets:230 V
    • 1U 16A 8 Outlet Switched + Metered PDU + Free Eco PDU Manager Software:100 - 240 V
  • Load capacity
    • NetShelter Rack PDU Advanced Gen 2, Metered, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlets:7400 VA
    • 1U 16A 8 Outlet Switched + Metered PDU + Free Eco PDU Manager Software:3680 VA

Side by side

Differences highlightedShow differences only (off)
Comparison of NetShelter Rack PDU Advanced Gen 2, Metered, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlets, PE8208G-ATB-G
54 specifications
Design2 differ
PDU typesDiffersMeteredMetered, Switched
TypeKnown for oneSingle-phaseUnknown — not stated by the source
Rack capacityDiffers0U1U
Product colourBlackBlack
MountingKnown for oneUnknown — not stated by the sourceHorizontal
On/off switchKnown for oneUnknown — not stated by the sourceYes
Ports & interfaces2 differ
AC outlets quantityDiffers40 AC outlet(s)8 AC outlet(s)
AC outlet typesDiffersC13 coupler, C15 coupler, C19 coupler, C21 couplerC13 coupler, C19 coupler
Ethernet LAN (RJ-45) portsKnown for one5Unknown — not stated by the source
USB ports quantityKnown for one1Unknown — not stated by the source
Input connection typeKnown for oneIEC 60309 32 A 2P + PEUnknown — not stated by the source
Power plugKnown for oneUnknown — not stated by the sourceC20 coupler
Featuresidentical
Cable length3 m3 m
LED indicatorsKnown for oneUnknown — not stated by the sourceYes
Management featuresidentical
Management platformKnown for oneNMC3Unknown — not stated by the source
Power5 differ
Nominal input voltageDiffers230 1 phase100 - 240 V
AC input frequencyDiffers50/60 Hz50 - 60 Hz
Maximum currentDiffers32 A16 A
Nominal output voltageDiffers230 V100 - 240 V
Output voltageKnown for one230 VUnknown — not stated by the source
Load capacityDiffers7400 VA3680 VA
Number of phasesKnown for one1Unknown — not stated by the source
Battery replacement accessibilityKnown for oneNon-removableUnknown — not stated by the source
Maximum powerKnown for oneUnknown — not stated by the source100 W
Certificates1 differ
Compliance certificatesKnown for oneRoHS, REACH, WEEEUnknown — not stated by the source
Waste Electrical and Electronic Equipment (WEEE) complianceKnown for oneYesUnknown — not stated by the source
CertificationDiffersUKCACE TUV-CB CE-LVD GOST
Weight & dimensions4 differ
WidthDiffers56 mm220.4 mm
DepthDiffers75 mm432.4 mm
HeightDiffers1490 mm44 mm
WeightDiffers6.2 kg3.38 kg
Packaging data3 differ
Package weightDiffers8.2 kg4.04 kg
Package width116 mm116 mm
Package depthDiffers208 mm499 mm
Package heightDiffers1720 mm324 mm
Technical detailsidentical
Preferred mounting positionKnown for oneno preferenceUnknown — not stated by the source
Removable batteryKnown for oneNoUnknown — not stated by the source
Packaging without single use plasticKnown for oneNoUnknown — not stated by the source
SCIP numberKnown for one31346aed-552c-4a16-81d9-e683a383b6daUnknown — not stated by the source
Sustainable packagingKnown for oneNoUnknown — not stated by the source
Take-back systemKnown for oneNoUnknown — not stated by the source
Logistics dataidentical
Country of originKnown for oneUnited StatesUnknown — not stated by the source
Customs product code (TARIC)Known for one8537109899Unknown — not stated by the source
Master (outer) case net weightKnown for oneUnknown — not stated by the source10.1 kg
Master (outer) case widthKnown for oneUnknown — not stated by the source388 mm
Master (outer) case lengthKnown for oneUnknown — not stated by the source519 mm
Master (outer) case heightKnown for oneUnknown — not stated by the source348 mm
Master (outer) case gross weightKnown for oneUnknown — not stated by the source13.3 kg
Products per master (outer) caseKnown for oneUnknown — not stated by the source3 pc(s)
Operational conditionsidentical
Operating temperature (T-T)Known for oneUnknown — not stated by the source0 - 50 °C
Storage temperature (T-T)Known for oneUnknown — not stated by the source-20 - 60 °C
Operating relative humidity (H-H)Known for oneUnknown — not stated by the source0 - 80%
Packaging contentidentical
Cables includedKnown for oneUnknown — not stated by the sourceAC
Rack mount kitKnown for oneUnknown — not stated by the sourceYes

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.

More power distribution units (pdus) comparisons

All power distribution units (pdus) comparisons