Product comparison · 2 power distribution units (pdus)

APC NetShelter Rack PDU Advanced Gen 2, Metered, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlets vs ATEN 2-Outlet Eco PDU Power Controller

Add a product
  • 21specifications compared
  • 19differ
  • 2identical
  • 34known for one product only

Key differences

The APC NetShelter Rack PDU Advanced Gen 2, Metered, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlets has 4 more Ethernet LAN (RJ-45) ports than the ATEN 2-Outlet Eco PDU Power Controller (5 vs 1). The APC NetShelter Rack PDU Advanced Gen 2, Metered, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlets has 22 A more maximum current than the ATEN 2-Outlet Eco PDU Power Controller (32 A vs 10 A). The APC NetShelter Rack PDU Advanced Gen 2, Metered, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlets has 5,000 VA more load capacity than the ATEN 2-Outlet Eco PDU Power Controller (7400 VA vs 2400 VA). PDU types: Metered on the APC NetShelter Rack PDU Advanced Gen 2, Metered, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlets, Managed on the ATEN 2-Outlet Eco PDU Power Controller. AC outlets quantity: 40 AC outlet(s) on the APC NetShelter Rack PDU Advanced Gen 2, Metered, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlets, 2 AC outlet(s) on the ATEN 2-Outlet Eco PDU Power Controller.

  • PDU types
    • NetShelter Rack PDU Advanced Gen 2, Metered, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlets:Metered
    • 2-Outlet Eco PDU Power Controller:Managed
  • AC outlets quantity
    • NetShelter Rack PDU Advanced Gen 2, Metered, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlets:40 AC outlet(s)
    • 2-Outlet Eco PDU Power Controller:2 AC outlet(s)
  • Ethernet LAN (RJ-45) ports
    • NetShelter Rack PDU Advanced Gen 2, Metered, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlets:5
    • 2-Outlet Eco PDU Power Controller:1
  • Nominal input voltage
    • NetShelter Rack PDU Advanced Gen 2, Metered, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlets:230 1 phase
    • 2-Outlet Eco PDU Power Controller:100 - 240 V
  • AC input frequency
    • NetShelter Rack PDU Advanced Gen 2, Metered, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlets:50/60 Hz
    • 2-Outlet Eco PDU Power Controller:50 - 60 Hz
  • Maximum current
    • NetShelter Rack PDU Advanced Gen 2, Metered, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlets:32 A
    • 2-Outlet Eco PDU Power Controller:10 A
  • Nominal output voltage
    • NetShelter Rack PDU Advanced Gen 2, Metered, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlets:230 V
    • 2-Outlet Eco PDU Power Controller:100 - 240 V
  • Load capacity
    • NetShelter Rack PDU Advanced Gen 2, Metered, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlets:7400 VA
    • 2-Outlet Eco PDU Power Controller:2400 VA

Side by side

Differences highlightedShow differences only (on)
Comparison of NetShelter Rack PDU Advanced Gen 2, Metered, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlets, PE4102G
55 specifications
Design1 differ
PDU typesDiffersMeteredManaged
TypeKnown for oneSingle-phaseUnknown — not stated by the source
Rack capacityKnown for one0UUnknown — not stated by the source
Rack mountingKnown for oneUnknown — not stated by the sourceYes
Mounting typeKnown for oneUnknown — not stated by the sourceDesk/Wall
Ports & interfaces3 differ
AC outlets quantityDiffers40 AC outlet(s)2 AC outlet(s)
AC outlet typesDiffersC13 coupler, C15 coupler, C19 coupler, C21 couplerC13 coupler
Ethernet LAN (RJ-45) portsDiffers51
USB ports quantityKnown for one1Unknown — not stated by the source
Input connection typeKnown for oneIEC 60309 32 A 2P + PEUnknown — not stated by the source
Power plugKnown for oneUnknown — not stated by the sourceC14 coupler
Featuresidentical
Password protectionKnown for oneUnknown — not stated by the sourceYes
Management featuresidentical
Management platformKnown for oneNMC3Unknown — not stated by the source
Supported network protocolsKnown for oneUnknown — not stated by the sourceTCP/IP, UDP, HTTP, HTTPS, SSL, SMTP, ARP, NTP, DNS, SNMP V1&V2&V3
Power5 differ
Nominal input voltageDiffers230 1 phase100 - 240 V
AC input frequencyDiffers50/60 Hz50 - 60 Hz
Maximum currentDiffers32 A10 A
Nominal output voltageDiffers230 V100 - 240 V
Output voltageKnown for one230 VUnknown — not stated by the source
Load capacityDiffers7400 VA2400 VA
Number of phasesKnown for one1Unknown — not stated by the source
Battery replacement accessibilityKnown for oneNon-removableUnknown — not stated by the source
Certificates1 differ
Compliance certificatesDiffersRoHS, REACH, WEEELow Voltage Directive (LVD), CE, Electromagnetic Compatibility (EMC)
Waste Electrical and Electronic Equipment (WEEE) complianceKnown for oneYesUnknown — not stated by the source
CertificationKnown for oneUKCAUnknown — not stated by the source
Weight & dimensions4 differ
WidthDiffers56 mm127.8 mm
DepthDiffers75 mm170 mm
HeightDiffers1490 mm44 mm
WeightDiffers6.2 kg980 g
Packaging data4 differ
Package weightDiffers8.2 kg1.27 kg
Package widthDiffers116 mm95 mm
Package depthDiffers208 mm265 mm
Package heightDiffers1720 mm220 mm
Package volumeKnown for oneUnknown — not stated by the source5550.101932032 cm³
Technical detailsidentical
Preferred mounting positionKnown for oneno preferenceUnknown — not stated by the source
Removable batteryKnown for oneNoUnknown — not stated by the source
Packaging without single use plasticKnown for oneNoUnknown — not stated by the source
SCIP numberKnown for one31346aed-552c-4a16-81d9-e683a383b6daUnknown — not stated by the source
Sustainable packagingKnown for oneNoUnknown — not stated by the source
Take-back systemKnown for oneNoUnknown — not stated by the source
Logistics data1 differ
Country of originDiffersUnited StatesChina
Customs product code (TARIC)Known for one8537109899Unknown — not stated by the source
Master (outer) case net weightKnown for oneUnknown — not stated by the source4.9 kg
Master (outer) case widthKnown for oneUnknown — not stated by the source232 mm
Master (outer) case lengthKnown for oneUnknown — not stated by the source500 mm
Master (outer) case heightKnown for oneUnknown — not stated by the source283 mm
Master (outer) case gross weightKnown for oneUnknown — not stated by the source6.92 kg
Master (outer) case volumeKnown for oneUnknown — not stated by the source32819.225200128 cm³
Operational conditionsidentical
Operating temperature (T-T)Known for oneUnknown — not stated by the source0 - 50 °C
Storage temperature (T-T)Known for oneUnknown — not stated by the source-20 - 60 °C
Operating relative humidity (H-H)Known for oneUnknown — not stated by the source0 - 80%
Packaging contentidentical
Cables includedKnown for oneUnknown — not stated by the sourceAC
ManualKnown for oneUnknown — not stated by the sourceYes

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.

More power distribution units (pdus) comparisons