Product comparison · 2 power distribution units (pdus)

APC NetShelter Rack PDU Advanced Gen 2, Metered, 3Phase, 11kW 400V 16A or 11.5kW 415V 20A, 520P6, 42 Outlet vs APC NetShelter Rack PDU Advanced Gen 2, Switched Metered Outlet,3Phase, 43.5kW 400V 63A or 34.6kW 415V 60A, 560P6, 42 Outlet

Add a product
  • 36specifications compared
  • 12differ
  • 24identical
  • 2known for one product only

Key differences

The APC NetShelter Rack PDU Advanced Gen 2, Switched Metered Outlet,3Phase, 43.5kW 400V 63A or 34.6kW 415V 60A, 560P6, 42 Outlet has 40 A more maximum current than the APC NetShelter Rack PDU Advanced Gen 2, Metered, 3Phase, 11kW 400V 16A or 11.5kW 415V 20A, 520P6, 42 Outlet (60 A vs 20 A). The APC NetShelter Rack PDU Advanced Gen 2, Switched Metered Outlet,3Phase, 43.5kW 400V 63A or 34.6kW 415V 60A, 560P6, 42 Outlet has 23,100 VA more load capacity than the APC NetShelter Rack PDU Advanced Gen 2, Metered, 3Phase, 11kW 400V 16A or 11.5kW 415V 20A, 520P6, 42 Outlet (34600 VA vs 11500 VA). The APC NetShelter Rack PDU Advanced Gen 2, Switched Metered Outlet,3Phase, 43.5kW 400V 63A or 34.6kW 415V 60A, 560P6, 42 Outlet has 20 mm more depth than the APC NetShelter Rack PDU Advanced Gen 2, Metered, 3Phase, 11kW 400V 16A or 11.5kW 415V 20A, 520P6, 42 Outlet (75 mm vs 55 mm). AC outlets quantity: 40 AC outlet(s) on the APC NetShelter Rack PDU Advanced Gen 2, Metered, 3Phase, 11kW 400V 16A or 11.5kW 415V 20A, 520P6, 42 Outlet, 42 AC outlet(s) on the APC NetShelter Rack PDU Advanced Gen 2, Switched Metered Outlet,3Phase, 43.5kW 400V 63A or 34.6kW 415V 60A, 560P6, 42 Outlet. Input connection type: IEC 60309 20 A 3P + N + PE on the APC NetShelter Rack PDU Advanced Gen 2, Metered, 3Phase, 11kW 400V 16A or 11.5kW 415V 20A, 520P6, 42 Outlet, IEC 60309 60 A 3P + N + PE on the APC NetShelter Rack PDU Advanced Gen 2, Switched Metered Outlet,3Phase, 43.5kW 400V 63A or 34.6kW 415V 60A, 560P6, 42 Outlet.

  • AC outlets quantity
    • NetShelter Rack PDU Advanced Gen 2, Metered, 3Phase, 11kW 400V 16A or 11.5kW 415V 20A, 520P6, 42 Outlet:40 AC outlet(s)
    • NetShelter Rack PDU Advanced Gen 2, Switched Metered Outlet,3Phase, 43.5kW 400V 63A or 34.6kW 415V 60A, 560P6, 42 Outlet:42 AC outlet(s)
  • Input connection type
    • NetShelter Rack PDU Advanced Gen 2, Metered, 3Phase, 11kW 400V 16A or 11.5kW 415V 20A, 520P6, 42 Outlet:IEC 60309 20 A 3P + N + PE
    • NetShelter Rack PDU Advanced Gen 2, Switched Metered Outlet,3Phase, 43.5kW 400V 63A or 34.6kW 415V 60A, 560P6, 42 Outlet:IEC 60309 60 A 3P + N + PE
  • Nominal input voltage
    • NetShelter Rack PDU Advanced Gen 2, Metered, 3Phase, 11kW 400V 16A or 11.5kW 415V 20A, 520P6, 42 Outlet:415 3 phases; 400 3 phases
    • NetShelter Rack PDU Advanced Gen 2, Switched Metered Outlet,3Phase, 43.5kW 400V 63A or 34.6kW 415V 60A, 560P6, 42 Outlet:415 3 phases
  • Maximum current
    • NetShelter Rack PDU Advanced Gen 2, Metered, 3Phase, 11kW 400V 16A or 11.5kW 415V 20A, 520P6, 42 Outlet:20 A
    • NetShelter Rack PDU Advanced Gen 2, Switched Metered Outlet,3Phase, 43.5kW 400V 63A or 34.6kW 415V 60A, 560P6, 42 Outlet:60 A
  • Load capacity
    • NetShelter Rack PDU Advanced Gen 2, Metered, 3Phase, 11kW 400V 16A or 11.5kW 415V 20A, 520P6, 42 Outlet:11500 VA
    • NetShelter Rack PDU Advanced Gen 2, Switched Metered Outlet,3Phase, 43.5kW 400V 63A or 34.6kW 415V 60A, 560P6, 42 Outlet:34600 VA
  • Depth
    • NetShelter Rack PDU Advanced Gen 2, Metered, 3Phase, 11kW 400V 16A or 11.5kW 415V 20A, 520P6, 42 Outlet:55 mm
    • NetShelter Rack PDU Advanced Gen 2, Switched Metered Outlet,3Phase, 43.5kW 400V 63A or 34.6kW 415V 60A, 560P6, 42 Outlet:75 mm
  • Height
    • NetShelter Rack PDU Advanced Gen 2, Metered, 3Phase, 11kW 400V 16A or 11.5kW 415V 20A, 520P6, 42 Outlet:1490 mm
    • NetShelter Rack PDU Advanced Gen 2, Switched Metered Outlet,3Phase, 43.5kW 400V 63A or 34.6kW 415V 60A, 560P6, 42 Outlet:1826 mm
  • Weight
    • NetShelter Rack PDU Advanced Gen 2, Metered, 3Phase, 11kW 400V 16A or 11.5kW 415V 20A, 520P6, 42 Outlet:5.7 kg
    • NetShelter Rack PDU Advanced Gen 2, Switched Metered Outlet,3Phase, 43.5kW 400V 63A or 34.6kW 415V 60A, 560P6, 42 Outlet:12.7 kg

Side by side

Differences highlightedShow differences only (off)
Comparison of NetShelter Rack PDU Advanced Gen 2, Metered, 3Phase, 11kW 400V 16A or 11.5kW 415V 20A, 520P6, 42 Outlet, NetShelter Rack PDU Advanced Gen 2, Switched Metered Outlet,3Phase, 43.5kW 400V 63A or 34.6kW 415V 60A, 560P6, 42 Outlet
38 specifications
Designidentical
PDU typesMeteredMetered
TypeThree-phaseThree-phase
Rack capacity0U0U
Product colourBlackBlack
Ports & interfaces2 differ
AC outlets quantityDiffers40 AC outlet(s)42 AC outlet(s)
AC outlet typesC13 coupler, C15 coupler, C19 coupler, C21 couplerC13 coupler, C15 coupler, C19 coupler, C21 coupler
Ethernet LAN (RJ-45) ports55
USB ports quantity11
Input connection typeDiffersIEC 60309 20 A 3P + N + PEIEC 60309 60 A 3P + N + PE
Featuresidentical
Cable length3 m3 m
Management featuresidentical
Management platformNMC3NMC3
Power3 differ
Nominal input voltageDiffers415 3 phases; 400 3 phases415 3 phases
AC input frequency50/60 Hz50/60 Hz
Maximum currentDiffers20 A60 A
Nominal output voltage400 V400 V
Output voltage240 V240 V
Load capacityDiffers11500 VA34600 VA
Number of phases33
Battery replacement accessibilityNon-removableNon-removable
Certificatesidentical
Compliance certificatesRoHS, REACH, WEEERoHS, REACH, WEEE
Waste Electrical and Electronic Equipment (WEEE) complianceYesYes
CertificationKnown for oneUKCAUnknown — not stated by the source
Weight & dimensions3 differ
Width56 mm56 mm
DepthDiffers55 mm75 mm
HeightDiffers1490 mm1826 mm
WeightDiffers5.7 kg12.7 kg
Packaging data4 differ
Package weightDiffers8.2 kg17 kg
Package widthDiffers116 mm132 mm
Package depthDiffers208 mm262 mm
Package heightDiffers1720 mm2110 mm
Technical detailsidentical
Preferred mounting positionno preferenceno preference
Removable batteryNoNo
Packaging without single use plasticNoNo
SCIP number31346aed-552c-4a16-81d9-e683a383b6da31346aed-552c-4a16-81d9-e683a383b6da
Sustainable packagingNoNo
Take-back systemNoNo
Logistics dataidentical
Customs product code (TARIC)85371098998537109899
Country of originKnown for oneUnknown — not stated by the sourceUnited States

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.

More power distribution units (pdus) comparisons

All power distribution units (pdus) comparisons