Product comparison · 2 power distribution units (pdus)

APC IT Power Distribution Module 2 Pole 3 Wire 30A L2-L3 L6-30 980cm vs APC SBP1500RM power distribution unit (PDU) 8 AC outlet(s) Black

Add a product
  • 25specifications compared
  • 21differ
  • 4identical
  • 5known for one product only

Key differences

  • PDU types
    • IT Power Distribution Module 2 Pole 3 Wire 30A L2-L3 L6-30 980cm:Metered, Monitored
    • SBP1500RM power distribution unit (PDU) 8 AC outlet(s) Black:Basic
  • AC outlets quantity
    • IT Power Distribution Module 2 Pole 3 Wire 30A L2-L3 L6-30 980cm:1 AC outlet(s)
    • SBP1500RM power distribution unit (PDU) 8 AC outlet(s) Black:8 AC outlet(s)
  • AC outlet types
    • IT Power Distribution Module 2 Pole 3 Wire 30A L2-L3 L6-30 980cm:NEMA L6-30R
    • SBP1500RM power distribution unit (PDU) 8 AC outlet(s) Black:NEMA 5–15R
  • Nominal input voltage
    • IT Power Distribution Module 2 Pole 3 Wire 30A L2-L3 L6-30 980cm:208 V
    • SBP1500RM power distribution unit (PDU) 8 AC outlet(s) Black:120 V
  • AC input frequency
    • IT Power Distribution Module 2 Pole 3 Wire 30A L2-L3 L6-30 980cm:60 Hz
    • SBP1500RM power distribution unit (PDU) 8 AC outlet(s) Black:50 - 60 Hz
  • Nominal output voltage
    • IT Power Distribution Module 2 Pole 3 Wire 30A L2-L3 L6-30 980cm:208 V
    • SBP1500RM power distribution unit (PDU) 8 AC outlet(s) Black:120 V
  • Maximum input current per phase
    • IT Power Distribution Module 2 Pole 3 Wire 30A L2-L3 L6-30 980cm:30 A
    • SBP1500RM power distribution unit (PDU) 8 AC outlet(s) Black:15 A
  • Maximum total current draw per phase
    • IT Power Distribution Module 2 Pole 3 Wire 30A L2-L3 L6-30 980cm:30 A
    • SBP1500RM power distribution unit (PDU) 8 AC outlet(s) Black:15 A

Side by side

Differences highlightedShow differences only (off)
Comparison of IT Power Distribution Module 2 Pole 3 Wire 30A L2-L3 L6-30 980cm, SBP1500RM
30 specifications
Design1 differ
PDU typesDiffersMetered, MonitoredBasic
Product colourBlackBlack
Ports & interfaces2 differ
AC outlets quantityDiffers1 AC outlet(s)8 AC outlet(s)
Power plugKnown for oneUnknown — not stated by the sourceNEMA 5–15P
AC outlet typesDiffersNEMA L6-30RNEMA 5–15R
Output connectionsKnown for oneUnknown — not stated by the source8 x NEMA 5-15R
Power5 differ
Nominal input voltageDiffers208 V120 V
AC input frequencyDiffers60 Hz50 - 60 Hz
Nominal output voltageDiffers208 V120 V
Load capacityKnown for oneUnknown — not stated by the source1500 VA
Maximum input current per phaseDiffers30 A15 A
Maximum total current draw per phaseDiffers30 A15 A
Certificates1 differ
Compliance certificatesRoHSRoHS
CertificationDiffersULTUV
Operational conditions4 differ
Operating temperature (T-T)Differs0 - 30 °C0 - 40 °C
Storage temperature (T-T)Differs-15 - 40 °C-15 - 45 °C
Operating relative humidity (H-H)0 - 95%0 - 95%
Storage relative humidity (H-H)0 - 95%0 - 95%
Operating altitudeDiffers0 - 3000 m0 - 4500 m
Non-operating altitudeDiffers0 - 4500 m0 - 15000 m
Weight & dimensions4 differ
WidthDiffers444 mm432 mm
DepthDiffers406 mm76 mm
HeightDiffers127 mm89 mm
WeightDiffers4.29 kg2.95 kg
Packaging data4 differ
Package weightDiffers5.2 kg3.8 kg
Package widthDiffers444 mm463 mm
Package depthDiffers406 mm295 mm
Package heightDiffers127 mm151 mm
Featuresidentical
LED indicatorsKnown for oneYesUnknown — not stated by the source
Cable lengthKnown for one9.8 mUnknown — not stated by the source

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.