Product comparison · 2 power distribution units (pdus)

APC EasyPDU, Switched, Zero U, 22 kW vs APC NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets

Add a product
  • 25specifications compared
  • 17differ
  • 8identical
  • 8known for one product only

Key differences

The APC EasyPDU, Switched, Zero U, 22 kW has 192 V more nominal input voltage than the APC NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets (400 V vs 208 V). The APC NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets has 68 A more maximum current than the APC EasyPDU, Switched, Zero U, 22 kW (100 A vs 32 A). The APC EasyPDU, Switched, Zero U, 22 kW has 22 V more output voltage than the APC NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets (230 V vs 208 V). PDU types: Switched on the APC EasyPDU, Switched, Zero U, 22 kW, Metered on the APC NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets. Power plug: C13 coupler on the APC EasyPDU, Switched, Zero U, 22 kW, IEC 60309 on the APC NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets.

  • PDU types
    • EasyPDU, Switched, Zero U, 22 kW:Switched
    • NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets:Metered
  • Power plug
    • EasyPDU, Switched, Zero U, 22 kW:C13 coupler
    • NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets:IEC 60309
  • Nominal input voltage
    • EasyPDU, Switched, Zero U, 22 kW:400 V
    • NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets:208 V
  • Maximum current
    • EasyPDU, Switched, Zero U, 22 kW:32 A
    • NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets:100 A
  • Output voltage
    • EasyPDU, Switched, Zero U, 22 kW:230 V
    • NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets:208 V
  • Load capacity
    • EasyPDU, Switched, Zero U, 22 kW:22080 VA
    • NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets:28800 VA
  • Operating temperature (T-T)
    • EasyPDU, Switched, Zero U, 22 kW:-5 - 50 °C
    • NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets:-5 - 60 °C
  • Storage temperature (T-T)
    • EasyPDU, Switched, Zero U, 22 kW:-25 - 65 °C
    • NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets:-20 - 60 °C

Side by side

Differences highlightedShow differences only (on)
Comparison of EPDU2232SX3620, NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets
33 specifications
Design1 differ
PDU typesDiffersSwitchedMetered
Ports & interfaces2 differ
Power plugDiffersC13 couplerIEC 60309
AC outlet typesDiffersC13 coupler, C19 couplerC15 coupler, C13 coupler, C19 coupler, C21 coupler
Power4 differ
Nominal input voltageDiffers400 V208 V
Maximum currentDiffers32 A100 A
Nominal output voltageKnown for one230 VUnknown — not stated by the source
Output voltageDiffers230 V208 V
Load capacityDiffers22080 VA28800 VA
Number of phasesKnown for one3Unknown — not stated by the source
Certificatesidentical
Compliance certificatesKnown for oneCE, UKCAUnknown — not stated by the source
Operational conditions3 differ
Operating temperature (T-T)Differs-5 - 50 °C-5 - 60 °C
Storage temperature (T-T)Differs-25 - 65 °C-20 - 60 °C
Operating relative humidity (H-H)Differs5 - 95%5 - 90%
Operating altitudeKnown for one0 - 3000 mUnknown — not stated by the source
Non-operating altitudeKnown for oneUnknown — not stated by the source0 - 15240 m
Weight & dimensions3 differ
DepthDiffers62 mm75 mm
HeightDiffers1800 mm1900 mm
WeightDiffers8.75 kg14 kg
Packaging data4 differ
Package weightDiffers10.6 kg19.8 kg
Package widthDiffers170 mm350 mm
Package depthDiffers1960 mm165 mm
Package heightDiffers1260 mm2110 mm
Logistics dataidentical
Total carbon footprint (kg of CO2e)Known for one2245Unknown — not stated by the source
Featuresidentical
International Protection (IP) codeKnown for oneUnknown — not stated by the sourceIP67
Management featuresidentical
Management platformKnown for oneUnknown — not stated by the sourceNMC3

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.