Product comparison · 2 power distribution units (pdus)

APC Easy PDU Metered Zero U 22 kW vs APC NetShelter power distribution unit (PDU) 40 AC outlet(s) 0U Black

Add a product
  • 20specifications compared
  • 15differ
  • 5identical
  • 13known for one product only

Key differences

The APC Easy PDU Metered Zero U 22 kW has 192 V more nominal input voltage than the APC NetShelter power distribution unit (PDU) 40 AC outlet(s) 0U Black (400 V vs 208 V). The APC Easy PDU Metered Zero U 22 kW has 8 A more maximum current than the APC NetShelter power distribution unit (PDU) 40 AC outlet(s) 0U Black (32 A vs 24 A). The APC Easy PDU Metered Zero U 22 kW has 22 V more nominal output voltage than the APC NetShelter power distribution unit (PDU) 40 AC outlet(s) 0U Black (230 V vs 208 V). Type: Three-phase on the APC Easy PDU Metered Zero U 22 kW, Single-phase on the APC NetShelter power distribution unit (PDU) 40 AC outlet(s) 0U Black. AC outlets quantity: 24 AC outlet(s) on the APC Easy PDU Metered Zero U 22 kW, 40 AC outlet(s) on the APC NetShelter power distribution unit (PDU) 40 AC outlet(s) 0U Black.

  • Type
    • Easy PDU Metered Zero U 22 kW:Three-phase
    • NetShelter power distribution unit (PDU) 40 AC outlet(s) 0U Black:Single-phase
  • AC outlets quantity
    • Easy PDU Metered Zero U 22 kW:24 AC outlet(s)
    • NetShelter power distribution unit (PDU) 40 AC outlet(s) 0U Black:40 AC outlet(s)
  • Nominal input voltage
    • Easy PDU Metered Zero U 22 kW:400 V
    • NetShelter power distribution unit (PDU) 40 AC outlet(s) 0U Black:208 V
  • Maximum current
    • Easy PDU Metered Zero U 22 kW:32 A
    • NetShelter power distribution unit (PDU) 40 AC outlet(s) 0U Black:24 A
  • Nominal output voltage
    • Easy PDU Metered Zero U 22 kW:230 V
    • NetShelter power distribution unit (PDU) 40 AC outlet(s) 0U Black:208 V
  • Load capacity
    • Easy PDU Metered Zero U 22 kW:22080 VA
    • NetShelter power distribution unit (PDU) 40 AC outlet(s) 0U Black:4992 VA
  • Number of phases
    • Easy PDU Metered Zero U 22 kW:3
    • NetShelter power distribution unit (PDU) 40 AC outlet(s) 0U Black:1
  • Depth
    • Easy PDU Metered Zero U 22 kW:56 mm
    • NetShelter power distribution unit (PDU) 40 AC outlet(s) 0U Black:75 mm

Side by side

Differences highlightedShow differences only (on)
Comparison of EPDU2232M, NetShelter
33 specifications
Design1 differ
TypeDiffersThree-phaseSingle-phase
MountingKnown for oneVerticalUnknown — not stated by the source
Ports & interfaces2 differ
AC outlets quantityDiffers24 AC outlet(s)40 AC outlet(s)
Power plugKnown for oneC13 couplerUnknown — not stated by the source
AC outlet typesDiffersC13 coupler, C19 couplerC13 coupler, C15 coupler, C19 coupler, C21 coupler
Ethernet LAN (RJ-45) portsKnown for oneUnknown — not stated by the source5
Power5 differ
Nominal input voltageDiffers400 V208 V
Maximum currentDiffers32 A24 A
Nominal output voltageDiffers230 V208 V
Output voltageKnown for one230 VUnknown — not stated by the source
Load capacityDiffers22080 VA4992 VA
Number of phasesDiffers31
Certificatesidentical
Compliance certificatesKnown for oneCE, UKCAUnknown — not stated by the source
CertificationKnown for oneUnknown — not stated by the sourceUKCA, CE, EN 62368-1, RoHS
Operational conditionsidentical
Operating temperature (T-T)Known for one-5 - 50 °CUnknown — not stated by the source
Storage temperature (T-T)Known for one-25 - 65 °CUnknown — not stated by the source
Operating relative humidity (H-H)Known for one5 - 95%Unknown — not stated by the source
Storage relative humidity (H-H)Known for one5 - 95%Unknown — not stated by the source
Operating altitudeKnown for one0 - 3000 mUnknown — not stated by the source
Weight & dimensions3 differ
DepthDiffers56 mm75 mm
HeightDiffers1650 mm1490 mm
WeightDiffers4.85 kg6.2 kg
Packaging data4 differ
Package weightDiffers6.05 kg8.2 kg
Package widthDiffers170 mm116 mm
Package depthDiffers1810 mm208 mm
Package heightDiffers1260 mm1720 mm
Logistics dataidentical
Total carbon footprint (kg of CO2e)Known for one1655Unknown — not stated by the source
Management featuresidentical
Management platformKnown for oneUnknown — not stated by the sourceNMC3

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.

More power distribution units (pdus) comparisons

All power distribution units (pdus) comparisons