Product comparison · 2 power distribution units (pdus)

APC Easy PDU Switched ZeroU 16A vs Vertiv MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black

Add a product
  • 17specifications compared
  • 14differ
  • 3identical
  • 22known for one product only

Key differences

The Vertiv MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black has 2 U more rack capacity than the APC Easy PDU Switched ZeroU 16A (2U vs 0U). The Vertiv MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black has 44 A more maximum current than the APC Easy PDU Switched ZeroU 16A (60 A vs 16 A). The Vertiv MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black has 10 V more nominal output voltage than the APC Easy PDU Switched ZeroU 16A (240 V vs 230 V). PDU types: Switched on the APC Easy PDU Switched ZeroU 16A, Monitored on the Vertiv MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black. Type: Single-phase on the APC Easy PDU Switched ZeroU 16A, Three-phase on the Vertiv MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black.

  • PDU types
    • Easy PDU Switched ZeroU 16A:Switched
    • MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black:Monitored
  • Type
    • Easy PDU Switched ZeroU 16A:Single-phase
    • MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black:Three-phase
  • Rack capacity
    • Easy PDU Switched ZeroU 16A:0U
    • MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black:2U
  • Mounting
    • Easy PDU Switched ZeroU 16A:Vertical
    • MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black:Horizontal
  • AC outlet types
    • Easy PDU Switched ZeroU 16A:C13 coupler
    • MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black:C13 coupler, C19 coupler
  • Nominal input voltage
    • Easy PDU Switched ZeroU 16A:230 V
    • MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black:200 - 415 V
  • Maximum current
    • Easy PDU Switched ZeroU 16A:16 A
    • MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black:60 A
  • Nominal output voltage
    • Easy PDU Switched ZeroU 16A:230 V
    • MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black:240 V

Side by side

Differences highlightedShow differences only (off)
Comparison of EPDU2116S, MN05MDR1-18I6B3-6PS56B0F10-S
39 specifications
Design4 differ
PDU typesDiffersSwitchedMonitored
TypeDiffersSingle-phaseThree-phase
Rack capacityDiffers0U2U
MountingDiffersVerticalHorizontal
Product colourBlackBlack
DisplayKnown for oneUnknown — not stated by the sourceLCD
Ports & interfaces1 differ
AC outlets quantity24 AC outlet(s)24 AC outlet(s)
Power plugKnown for oneIEC 60309Unknown — not stated by the source
AC outlet typesDiffersC13 couplerC13 coupler, C19 coupler
Ethernet LAN (RJ-45) portsKnown for oneUnknown — not stated by the source2
Power4 differ
Nominal input voltageDiffers230 V200 - 415 V
AC input frequency50/60 Hz50/60 Hz
Maximum currentDiffers16 A60 A
Nominal output voltageDiffers230 V240 V
Output voltageKnown for one230 VUnknown — not stated by the source
Load capacityDiffers3680 VA34500 VA
Number of phasesKnown for one1Unknown — not stated by the source
Maximum powerKnown for oneUnknown — not stated by the source34500 W
Power protection featuresKnown for oneUnknown — not stated by the sourceOver current
Certificates1 differ
Compliance certificatesDiffersCE, UKCACE, cUL, UL, UKCA, RoHS, RCM, Federal Communications Commission (FCC), China RoHS
Operational conditionsidentical
Operating temperature (T-T)Known for one-5 - 50 °CUnknown — not stated by the source
Storage temperature (T-T)Known for one-25 - 65 °CUnknown — not stated by the source
Operating relative humidity (H-H)Known for one5 - 95%Unknown — not stated by the source
Storage relative humidity (H-H)Known for one5 - 95%Unknown — not stated by the source
Operating altitudeKnown for one0 - 3000 mUnknown — not stated by the source
Weight & dimensions4 differ
WidthDiffers56 mm435 mm
DepthDiffers62 mm740 mm
HeightDiffers1650 mm88 mm
WeightDiffers6.1 kg11.3 kg
Packaging dataidentical
Package weightKnown for one7.6 kgUnknown — not stated by the source
Package widthKnown for one170 mmUnknown — not stated by the source
Package depthKnown for one1810 mmUnknown — not stated by the source
Package heightKnown for one1260 mmUnknown — not stated by the source
Logistics dataidentical
Total carbon footprint (kg of CO2e)Known for one1088Unknown — not stated by the source
Featuresidentical
Daisy chainKnown for oneUnknown — not stated by the sourceYes
Reset buttonKnown for oneUnknown — not stated by the sourceYes
Cable lengthKnown for oneUnknown — not stated by the source3 m
Management featuresidentical
MonitoringKnown for oneUnknown — not stated by the sourceCurrent, Power, Voltage
Supported network protocolsKnown for oneUnknown — not stated by the sourceDHCP, HTTP, HTTPS, IPv4, IPv6, LDAP, NTP, RADIUS, RSTP, SSH, SMTP, SNMP (v1/v2c/v3), Syslog, TACACS+, Modbus TCP

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.