Product comparison · 2 power distribution units (pdus)

APC Easy PDU Switched ZeroU 16A vs APC Easy PDU Metered Zero U 32A

Add a product
  • 30specifications compared
  • 12differ
  • 18identical
  • 0known for one product only

Key differences

The APC Easy PDU Metered Zero U 32A has 16 A more maximum current than the APC Easy PDU Switched ZeroU 16A (32 A vs 16 A). The APC Easy PDU Metered Zero U 32A has 3,680 VA more load capacity than the APC Easy PDU Switched ZeroU 16A (7360 VA vs 3680 VA). The APC Easy PDU Switched ZeroU 16A has 6 mm more depth than the APC Easy PDU Metered Zero U 32A (62 mm vs 56 mm). PDU types: Switched on the APC Easy PDU Switched ZeroU 16A, Metered on the APC Easy PDU Metered Zero U 32A. Power plug: IEC 60309 on the APC Easy PDU Switched ZeroU 16A, IEC309 on the APC Easy PDU Metered Zero U 32A.

  • PDU types
    • Easy PDU Switched ZeroU 16A:Switched
    • Easy PDU Metered Zero U 32A:Metered
  • Power plug
    • Easy PDU Switched ZeroU 16A:IEC 60309
    • Easy PDU Metered Zero U 32A:IEC309
  • Maximum current
    • Easy PDU Switched ZeroU 16A:16 A
    • Easy PDU Metered Zero U 32A:32 A
  • Load capacity
    • Easy PDU Switched ZeroU 16A:3680 VA
    • Easy PDU Metered Zero U 32A:7360 VA
  • Depth
    • Easy PDU Switched ZeroU 16A:62 mm
    • Easy PDU Metered Zero U 32A:56 mm
  • Height
    • Easy PDU Switched ZeroU 16A:1650 mm
    • Easy PDU Metered Zero U 32A:1400 mm
  • Weight
    • Easy PDU Switched ZeroU 16A:6.1 kg
    • Easy PDU Metered Zero U 32A:3.35 kg
  • Package weight
    • Easy PDU Switched ZeroU 16A:7.6 kg
    • Easy PDU Metered Zero U 32A:4.35 kg

Side by side

Differences highlightedShow differences only (on)
Comparison of EPDU2116S, EPDU2132M
30 specifications
Design1 differ
PDU typesDiffersSwitchedMetered
Ports & interfaces1 differ
Power plugDiffersIEC 60309IEC309
Power2 differ
Maximum currentDiffers16 A32 A
Load capacityDiffers3680 VA7360 VA
Weight & dimensions3 differ
DepthDiffers62 mm56 mm
HeightDiffers1650 mm1400 mm
WeightDiffers6.1 kg3.35 kg
Packaging data4 differ
Package weightDiffers7.6 kg4.35 kg
Package widthDiffers170 mm260 mm
Package depthDiffers1810 mm1560 mm
Package heightDiffers1260 mm680 mm
Logistics data1 differ
Total carbon footprint (kg of CO2e)Differs1088806

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.

More power distribution units (pdus) comparisons