Product comparison · 2 power distribution units (pdus)

APC Easy PDU Metered ZeroU 16A vs APC NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets

Add a product
  • 26specifications compared
  • 21differ
  • 5identical
  • 18known for one product only

Key differences

The APC NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets has 84 A more maximum current than the APC Easy PDU Metered ZeroU 16A (100 A vs 16 A). The APC NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets has 65,320 VA more load capacity than the APC Easy PDU Metered ZeroU 16A (69000 VA vs 3680 VA). The APC NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets has 2 more phases than the APC Easy PDU Metered ZeroU 16A (3 vs 1). Type: Single-phase on the APC Easy PDU Metered ZeroU 16A, Three-phase on the APC NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets. AC outlets quantity: 21 AC outlet(s) on the APC Easy PDU Metered ZeroU 16A, 18 AC outlet(s) on the APC NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets.

  • Type
    • Easy PDU Metered ZeroU 16A:Single-phase
    • NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets:Three-phase
  • AC outlets quantity
    • Easy PDU Metered ZeroU 16A:21 AC outlet(s)
    • NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets:18 AC outlet(s)
  • Power plug
    • Easy PDU Metered ZeroU 16A:IEC 60309
    • NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets:IEC309
  • Nominal input voltage
    • Easy PDU Metered ZeroU 16A:230 V
    • NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets:415 3 phases
  • Maximum current
    • Easy PDU Metered ZeroU 16A:16 A
    • NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets:100 A
  • Output voltage
    • Easy PDU Metered ZeroU 16A:230 V
    • NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets:415 V AC 3 phases
  • Load capacity
    • Easy PDU Metered ZeroU 16A:3680 VA
    • NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets:69000 VA
  • Number of phases
    • Easy PDU Metered ZeroU 16A:1
    • NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets:3

Side by side

Differences highlightedShow differences only (on)
Comparison of EPDU2116M, NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets
44 specifications
Design1 differ
TypeDiffersSingle-phaseThree-phase
UpgradeableKnown for oneUnknown — not stated by the sourceYes
Ports & interfaces3 differ
AC outlets quantityDiffers21 AC outlet(s)18 AC outlet(s)
Power plugDiffersIEC 60309IEC309
AC outlet typesDiffersC13 couplerC13 coupler, C15 coupler, C19 coupler, C21 coupler
Input connection typeKnown for oneUnknown — not stated by the sourceIEC 309 100 A
Featuresidentical
International Protection (IP) codeKnown for oneUnknown — not stated by the sourceIP67
Management featuresidentical
Management platformKnown for oneUnknown — not stated by the sourceNMC3
Power5 differ
Nominal input voltageDiffers230 V415 3 phases
Maximum currentDiffers16 A100 A
Output voltageDiffers230 V415 V AC 3 phases
Load capacityDiffers3680 VA69000 VA
Number of phasesDiffers13
AC input frequencyKnown for one50/60 HzUnknown — not stated by the source
Nominal output voltageKnown for one230 VUnknown — not stated by the source
Certificates1 differ
Compliance certificatesDiffersCE, UKCARoHS, REACH, WEEE
Waste Electrical and Electronic Equipment (WEEE) complianceKnown for oneUnknown — not stated by the sourceYes
Sustainabilityidentical
Doesn't containKnown for oneUnknown — not stated by the sourceSilicone
Operational conditions3 differ
Operating temperature (T-T)Differs-5 - 50 °C-5 - 60 °C
Storage temperature (T-T)Differs-25 - 65 °C-20 - 60 °C
Operating relative humidity (H-H)Differs5 - 95%5 - 90%
Non-operating altitudeKnown for oneUnknown — not stated by the source0 - 15240 m
Operating altitudeKnown for one0 - 3000 mUnknown — not stated by the source
Weight & dimensions4 differ
WidthDiffers56 mm59 mm
DepthDiffers56 mm87 mm
HeightDiffers1400 mm1750 mm
WeightDiffers3.05 kg18.8 kg
Packaging data4 differ
Package weightDiffers4.05 kg24.6 kg
Package widthDiffers260 mm350 mm
Package depthDiffers1560 mm165 mm
Package heightDiffers680 mm1980 mm
Technical detailsidentical
Packaging recycled materialsKnown for oneUnknown — not stated by the sourceRecycled cardboard
Preferred mounting positionKnown for oneUnknown — not stated by the sourceno preference
Packaging without single use plasticKnown for oneUnknown — not stated by the sourceYes
SCIP numberKnown for oneUnknown — not stated by the source7547f066-9302-46d9-96e9-461928dd6901
Sustainable packagingKnown for oneUnknown — not stated by the sourceNo
Take-back systemKnown for oneUnknown — not stated by the sourceNo
Logistics dataidentical
Customs product code (TARIC)Known for oneUnknown — not stated by the source8537109899
Total carbon footprint (kg of CO2e)Known for one580Unknown — not stated by the source

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.

More power distribution units (pdus) comparisons

All power distribution units (pdus) comparisons