Product comparison · 2 power distribution units (pdus)

APC Easy PDU Metered ZeroU 16A vs APC NetShelter power distribution unit (PDU) 40 AC outlet(s) 0U Black

Add a product
  • 20specifications compared
  • 13differ
  • 7identical
  • 13known for one product only

Key differences

The APC Easy PDU Metered ZeroU 16A has 22 V more nominal input voltage than the APC NetShelter power distribution unit (PDU) 40 AC outlet(s) 0U Black (230 V vs 208 V). The APC NetShelter power distribution unit (PDU) 40 AC outlet(s) 0U Black has 8 A more maximum current than the APC Easy PDU Metered ZeroU 16A (24 A vs 16 A). The APC Easy PDU Metered ZeroU 16A has 22 V more nominal output voltage than the APC NetShelter power distribution unit (PDU) 40 AC outlet(s) 0U Black (230 V vs 208 V). AC outlets quantity: 21 AC outlet(s) on the APC Easy PDU Metered ZeroU 16A, 40 AC outlet(s) on the APC NetShelter power distribution unit (PDU) 40 AC outlet(s) 0U Black.

  • AC outlets quantity
    • Easy PDU Metered ZeroU 16A:21 AC outlet(s)
    • NetShelter power distribution unit (PDU) 40 AC outlet(s) 0U Black:40 AC outlet(s)
  • Nominal input voltage
    • Easy PDU Metered ZeroU 16A:230 V
    • NetShelter power distribution unit (PDU) 40 AC outlet(s) 0U Black:208 V
  • Maximum current
    • Easy PDU Metered ZeroU 16A:16 A
    • NetShelter power distribution unit (PDU) 40 AC outlet(s) 0U Black:24 A
  • Nominal output voltage
    • Easy PDU Metered ZeroU 16A:230 V
    • NetShelter power distribution unit (PDU) 40 AC outlet(s) 0U Black:208 V
  • Load capacity
    • Easy PDU Metered ZeroU 16A:3680 VA
    • NetShelter power distribution unit (PDU) 40 AC outlet(s) 0U Black:4992 VA
  • Depth
    • Easy PDU Metered ZeroU 16A:56 mm
    • NetShelter power distribution unit (PDU) 40 AC outlet(s) 0U Black:75 mm
  • Height
    • Easy PDU Metered ZeroU 16A:1400 mm
    • NetShelter power distribution unit (PDU) 40 AC outlet(s) 0U Black:1490 mm
  • Weight
    • Easy PDU Metered ZeroU 16A:3.05 kg
    • NetShelter power distribution unit (PDU) 40 AC outlet(s) 0U Black:6.2 kg

Side by side

Differences highlightedShow differences only (off)
Comparison of EPDU2116M, NetShelter
33 specifications
Designidentical
PDU typesMeteredMetered
TypeSingle-phaseSingle-phase
Rack capacity0U0U
MountingKnown for oneVerticalUnknown — not stated by the source
Product colourBlackBlack
Ports & interfaces2 differ
AC outlets quantityDiffers21 AC outlet(s)40 AC outlet(s)
Power plugKnown for oneIEC 60309Unknown — not stated by the source
AC outlet typesDiffersC13 couplerC13 coupler, C15 coupler, C19 coupler, C21 coupler
Ethernet LAN (RJ-45) portsKnown for oneUnknown — not stated by the source5
Power4 differ
Nominal input voltageDiffers230 V208 V
AC input frequency50/60 Hz50/60 Hz
Maximum currentDiffers16 A24 A
Nominal output voltageDiffers230 V208 V
Output voltageKnown for one230 VUnknown — not stated by the source
Load capacityDiffers3680 VA4992 VA
Number of phases11
Certificatesidentical
Compliance certificatesKnown for oneCE, UKCAUnknown — not stated by the source
CertificationKnown for oneUnknown — not stated by the sourceUKCA, CE, EN 62368-1, RoHS
Operational conditionsidentical
Operating temperature (T-T)Known for one-5 - 50 °CUnknown — not stated by the source
Storage temperature (T-T)Known for one-25 - 65 °CUnknown — not stated by the source
Operating relative humidity (H-H)Known for one5 - 95%Unknown — not stated by the source
Storage relative humidity (H-H)Known for one5 - 95%Unknown — not stated by the source
Operating altitudeKnown for one0 - 3000 mUnknown — not stated by the source
Weight & dimensions3 differ
Width56 mm56 mm
DepthDiffers56 mm75 mm
HeightDiffers1400 mm1490 mm
WeightDiffers3.05 kg6.2 kg
Packaging data4 differ
Package weightDiffers4.05 kg8.2 kg
Package widthDiffers260 mm116 mm
Package depthDiffers1560 mm208 mm
Package heightDiffers680 mm1720 mm
Logistics dataidentical
Total carbon footprint (kg of CO2e)Known for one580Unknown — not stated by the source
Management featuresidentical
Management platformKnown for oneUnknown — not stated by the sourceNMC3

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.

More power distribution units (pdus) comparisons

All power distribution units (pdus) comparisons