The ATEN 32A 8-Outlet 1U Metered & Switched PDU + Free Eco PDU Manager Software has 16 A more maximum current than the APC Easy PDU Metered 1U 16A (32 A vs 16 A). The ATEN 32A 8-Outlet 1U Metered & Switched PDU + Free Eco PDU Manager Software has 4,000 VA more load capacity than the APC Easy PDU Metered 1U 16A (7680 VA vs 3680 VA). The APC Easy PDU Metered 1U 16A has 272 mm more width than the ATEN 32A 8-Outlet 1U Metered & Switched PDU + Free Eco PDU Manager Software (482 mm vs 210 mm). PDU types: Metered on the APC Easy PDU Metered 1U 16A, Switched on the ATEN 32A 8-Outlet 1U Metered & Switched PDU + Free Eco PDU Manager Software. Power plug: C13 coupler on the APC Easy PDU Metered 1U 16A, IEC 60309 on the ATEN 32A 8-Outlet 1U Metered & Switched PDU + Free Eco PDU Manager Software.

  • PDU types
    • Easy PDU Metered 1U 16A:Metered
    • 32A 8-Outlet 1U Metered & Switched PDU + Free Eco PDU Manager Software:Switched
  • Power plug
    • Easy PDU Metered 1U 16A:C13 coupler
    • 32A 8-Outlet 1U Metered & Switched PDU + Free Eco PDU Manager Software:IEC 60309
  • AC outlet types
    • Easy PDU Metered 1U 16A:C13 coupler
    • 32A 8-Outlet 1U Metered & Switched PDU + Free Eco PDU Manager Software:C13 coupler, C19 coupler
  • Nominal input voltage
    • Easy PDU Metered 1U 16A:230 V
    • 32A 8-Outlet 1U Metered & Switched PDU + Free Eco PDU Manager Software:100 - 240 V
  • AC input frequency
    • Easy PDU Metered 1U 16A:50/60 Hz
    • 32A 8-Outlet 1U Metered & Switched PDU + Free Eco PDU Manager Software:50-60 Hz
  • Maximum current
    • Easy PDU Metered 1U 16A:16 A
    • 32A 8-Outlet 1U Metered & Switched PDU + Free Eco PDU Manager Software:32 A
  • Output voltage
    • Easy PDU Metered 1U 16A:208 V
    • 32A 8-Outlet 1U Metered & Switched PDU + Free Eco PDU Manager Software:100 - 240 V
  • Load capacity
    • Easy PDU Metered 1U 16A:3680 VA
    • 32A 8-Outlet 1U Metered & Switched PDU + Free Eco PDU Manager Software:7680 VA

Side by side

Differences highlightedShow differences only (on)
Comparison of EPDU2016M, PG6308G
39 specifications
Design1 differ
PDU typesDiffersMeteredSwitched
TypeKnown for oneSingle-phaseUnknown — not stated by the source
MountingKnown for oneVerticalUnknown — not stated by the source
DisplayKnown for oneUnknown — not stated by the sourceLCD
Ports & interfaces2 differ
Power plugDiffersC13 couplerIEC 60309
AC outlet typesDiffersC13 couplerC13 coupler, C19 coupler
Ethernet LAN (RJ-45) portsKnown for oneUnknown — not stated by the source2
USB ports quantityKnown for oneUnknown — not stated by the source1
Power5 differ
Nominal input voltageDiffers230 V100 - 240 V
AC input frequencyDiffers50/60 Hz50-60 Hz
Maximum currentDiffers16 A32 A
Nominal output voltageKnown for one208 VUnknown — not stated by the source
Output voltageDiffers208 V100 - 240 V
Load capacityDiffers3680 VA7680 VA
Number of phasesKnown for one1Unknown — not stated by the source
Certificatesidentical
Compliance certificatesKnown for oneCE, UKCAUnknown — not stated by the source
CertificationKnown for oneUnknown — not stated by the sourceCE, UKCA
Operational conditions3 differ
Operating temperature (T-T)Differs-5 - 50 °C0 - 60 °C
Storage temperature (T-T)Differs-25 - 65 °C-20 - 60 °C
Operating relative humidity (H-H)Differs5 - 95%0 - 80%
Storage relative humidity (H-H)Known for one5 - 95%Unknown — not stated by the source
Operating altitudeKnown for one0 - 3000 mUnknown — not stated by the source
Weight & dimensions3 differ
WidthDiffers482 mm210 mm
DepthDiffers100 mm432.4 mm
WeightDiffers1.7 kg4.09 kg
Packaging dataidentical
Package weightKnown for one3 kgUnknown — not stated by the source
Package widthKnown for one210 mmUnknown — not stated by the source
Package depthKnown for one570 mmUnknown — not stated by the source
Package heightKnown for one680 mmUnknown — not stated by the source
Logistics dataidentical
Total carbon footprint (kg of CO2e)Known for one649Unknown — not stated by the source
Country of originKnown for oneUnknown — not stated by the sourceTaiwan
Featuresidentical
Reset buttonKnown for oneUnknown — not stated by the sourceYes
LED indicatorsKnown for oneUnknown — not stated by the sourceYes
Cable lengthKnown for oneUnknown — not stated by the source3 m
Management featuresidentical
MonitoringKnown for oneUnknown — not stated by the sourceCurrent, Voltage