Product comparison · 2 power distribution units (pdus)

APC Easy PDU Metered 1U 16A vs APC NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets

Add a product
  • 25specifications compared
  • 19differ
  • 6identical
  • 8known for one product only

Key differences

The APC Easy PDU Metered 1U 16A has 1 U more rack capacity than the APC NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets (1U vs 0U). The APC Easy PDU Metered 1U 16A has 22 V more nominal input voltage than the APC NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets (230 V vs 208 V). The APC NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets has 84 A more maximum current than the APC Easy PDU Metered 1U 16A (100 A vs 16 A). Type: Single-phase on the APC Easy PDU Metered 1U 16A, Three-phase on the APC NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets. AC outlets quantity: 8 AC outlet(s) on the APC Easy PDU Metered 1U 16A, 30 AC outlet(s) on the APC NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets.

  • Type
    • Easy PDU Metered 1U 16A:Single-phase
    • NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets:Three-phase
  • Rack capacity
    • Easy PDU Metered 1U 16A:1U
    • NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets:0U
  • AC outlets quantity
    • Easy PDU Metered 1U 16A:8 AC outlet(s)
    • NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets:30 AC outlet(s)
  • Power plug
    • Easy PDU Metered 1U 16A:C13 coupler
    • NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets:IEC 60309
  • Nominal input voltage
    • Easy PDU Metered 1U 16A:230 V
    • NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets:208 V
  • Maximum current
    • Easy PDU Metered 1U 16A:16 A
    • NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets:100 A
  • Load capacity
    • Easy PDU Metered 1U 16A:3680 VA
    • NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets:28800 VA
  • Operating temperature (T-T)
    • Easy PDU Metered 1U 16A:-5 - 50 °C
    • NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets:-5 - 60 °C

Side by side

Differences highlightedShow differences only (on)
Comparison of EPDU2016M, NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets
33 specifications
Design2 differ
TypeDiffersSingle-phaseThree-phase
Rack capacityDiffers1U0U
Ports & interfaces3 differ
AC outlets quantityDiffers8 AC outlet(s)30 AC outlet(s)
Power plugDiffersC13 couplerIEC 60309
AC outlet typesDiffersC13 couplerC15 coupler, C13 coupler, C19 coupler, C21 coupler
Power3 differ
Nominal input voltageDiffers230 V208 V
Maximum currentDiffers16 A100 A
Nominal output voltageKnown for one208 VUnknown — not stated by the source
Load capacityDiffers3680 VA28800 VA
Number of phasesKnown for one1Unknown — not stated by the source
Certificatesidentical
Compliance certificatesKnown for oneCE, UKCAUnknown — not stated by the source
Operational conditions3 differ
Operating temperature (T-T)Differs-5 - 50 °C-5 - 60 °C
Storage temperature (T-T)Differs-25 - 65 °C-20 - 60 °C
Operating relative humidity (H-H)Differs5 - 95%5 - 90%
Operating altitudeKnown for one0 - 3000 mUnknown — not stated by the source
Non-operating altitudeKnown for oneUnknown — not stated by the source0 - 15240 m
Weight & dimensions4 differ
WidthDiffers482 mm56 mm
DepthDiffers100 mm75 mm
HeightDiffers44 mm1900 mm
WeightDiffers1.7 kg14 kg
Packaging data4 differ
Package weightDiffers3 kg19.8 kg
Package widthDiffers210 mm350 mm
Package depthDiffers570 mm165 mm
Package heightDiffers680 mm2110 mm
Logistics dataidentical
Total carbon footprint (kg of CO2e)Known for one649Unknown — not stated by the source
Featuresidentical
International Protection (IP) codeKnown for oneUnknown — not stated by the sourceIP67
Management featuresidentical
Management platformKnown for oneUnknown — not stated by the sourceNMC3

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.