Product comparison · 2 power distribution units (pdus)

APC Easy PDU Metered 1U 16A vs APC Easy PDU Metered Zero U 32A

Add a product
  • 30specifications compared
  • 15differ
  • 15identical
  • 0known for one product only

Key differences

  • Rack capacity
    • Easy PDU Metered 1U 16A:1U
    • Easy PDU Metered Zero U 32A:0U
  • AC outlets quantity
    • Easy PDU Metered 1U 16A:8 AC outlet(s)
    • Easy PDU Metered Zero U 32A:24 AC outlet(s)
  • Power plug
    • Easy PDU Metered 1U 16A:C13 coupler
    • Easy PDU Metered Zero U 32A:IEC309
  • Maximum current
    • Easy PDU Metered 1U 16A:16 A
    • Easy PDU Metered Zero U 32A:32 A
  • Nominal output voltage
    • Easy PDU Metered 1U 16A:208 V
    • Easy PDU Metered Zero U 32A:230 V
  • Output voltage
    • Easy PDU Metered 1U 16A:208 V
    • Easy PDU Metered Zero U 32A:230 V
  • Load capacity
    • Easy PDU Metered 1U 16A:3680 VA
    • Easy PDU Metered Zero U 32A:7360 VA
  • Width
    • Easy PDU Metered 1U 16A:482 mm
    • Easy PDU Metered Zero U 32A:56 mm

Side by side

Differences highlightedShow differences only (off)
Comparison of EPDU2016M, EPDU2132M
30 specifications
Design1 differ
PDU typesMeteredMetered
TypeSingle-phaseSingle-phase
Rack capacityDiffers1U0U
MountingVerticalVertical
Product colourBlackBlack
Ports & interfaces2 differ
AC outlets quantityDiffers8 AC outlet(s)24 AC outlet(s)
Power plugDiffersC13 couplerIEC309
AC outlet typesC13 couplerC13 coupler
Power4 differ
Nominal input voltage230 V230 V
AC input frequency50/60 Hz50/60 Hz
Maximum currentDiffers16 A32 A
Nominal output voltageDiffers208 V230 V
Output voltageDiffers208 V230 V
Load capacityDiffers3680 VA7360 VA
Number of phases11
Certificatesidentical
Compliance certificatesCE, UKCACE, UKCA
Operational conditionsidentical
Operating temperature (T-T)-5 - 50 °C-5 - 50 °C
Storage temperature (T-T)-25 - 65 °C-25 - 65 °C
Operating relative humidity (H-H)5 - 95%5 - 95%
Storage relative humidity (H-H)5 - 95%5 - 95%
Operating altitude0 - 3000 m0 - 3000 m
Weight & dimensions4 differ
WidthDiffers482 mm56 mm
DepthDiffers100 mm56 mm
HeightDiffers44 mm1400 mm
WeightDiffers1.7 kg3.35 kg
Packaging data3 differ
Package weightDiffers3 kg4.35 kg
Package widthDiffers210 mm260 mm
Package depthDiffers570 mm1560 mm
Package height680 mm680 mm
Logistics data1 differ
Total carbon footprint (kg of CO2e)Differs649806