Product comparison · 2 power distribution units (pdus)

APC Basic Rack PDU AP9572 vs APC RackPDU, Metered, ZeroU, 16A, 230V, (20)C13 & (4)C19; IEC C20

Add a product
  • 13specifications compared
  • 7differ
  • 6identical
  • 17known for one product only

Key differences

  • Nominal input voltage
    • Basic Rack PDU AP9572:23 V
    • RackPDU, Metered, ZeroU, 16A, 230V, (20)C13 & (4)C19; IEC C20:230 V
  • Operating relative humidity (H-H)
    • Basic Rack PDU AP9572:5 - 95%
    • RackPDU, Metered, ZeroU, 16A, 230V, (20)C13 & (4)C19; IEC C20:0 - 95%
  • Storage relative humidity (H-H)
    • Basic Rack PDU AP9572:5 - 95%
    • RackPDU, Metered, ZeroU, 16A, 230V, (20)C13 & (4)C19; IEC C20:0 - 95%
  • Width
    • Basic Rack PDU AP9572:44 mm
    • RackPDU, Metered, ZeroU, 16A, 230V, (20)C13 & (4)C19; IEC C20:56 mm
  • Height
    • Basic Rack PDU AP9572:620 mm
    • RackPDU, Metered, ZeroU, 16A, 230V, (20)C13 & (4)C19; IEC C20:1619 mm
  • Weight
    • Basic Rack PDU AP9572:2 kg
    • RackPDU, Metered, ZeroU, 16A, 230V, (20)C13 & (4)C19; IEC C20:4.32 kg

Side by side

Differences highlightedShow differences only (on)
Comparison of Basic Rack PDU AP9572, RackPDU, Metered, ZeroU, 16A, 230V, (20)C13 & (4)C19; IEC C20
30 specifications
Designidentical
PDU typesKnown for oneBasicUnknown — not stated by the source
Rack capacityKnown for one0UUnknown — not stated by the source
MountingKnown for oneVerticalUnknown — not stated by the source
Ports & interfaces1 differ
AC outlets quantityKnown for one15 AC outlet(s)Unknown — not stated by the source
Power plugKnown for oneC20 couplerUnknown — not stated by the source
AC outlet typesKnown for oneC13 couplerUnknown — not stated by the source
Output connectionsDiffers(15) IEC 320 C13(20) IEC 320 C13 (4) IEC 320 C19
I/O portsKnown for oneUnknown — not stated by the source(20) IEC 320 C13 (4) IEC 320 C19 IEC-320 C20
Featuresidentical
Cable lengthKnown for one2.5 mUnknown — not stated by the source
Power1 differ
Nominal input voltageDiffers23 V230 V
Load capacityKnown for one3680 VAUnknown — not stated by the source
Maximum input current per phaseKnown for one16 AUnknown — not stated by the source
Maximum total current draw per phaseKnown for one16 AUnknown — not stated by the source
Maximum powerKnown for one3680 WUnknown — not stated by the source
Nominal output voltageKnown for oneUnknown — not stated by the source230 V
Operational conditions2 differ
Operating relative humidity (H-H)Differs5 - 95%0 - 95%
Storage relative humidity (H-H)Differs5 - 95%0 - 95%
Weight & dimensions3 differ
WidthDiffers44 mm56 mm
HeightDiffers620 mm1619 mm
WeightDiffers2 kg4.32 kg
Packaging dataidentical
Package weightKnown for oneUnknown — not stated by the source7.73 kg
Package widthKnown for oneUnknown — not stated by the source152 mm
Package depthKnown for oneUnknown — not stated by the source127 mm
Package heightKnown for oneUnknown — not stated by the source2134 mm

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.