Product comparison · 2 power distribution units (pdus)

APC BASIC RACK DISTRIBUTION PANEL 230 V IN A RACK vs APC RackPDU, Metered, ZeroU, 16A, 230V, (20)C13 & (4)C19; IEC C20

Add a product
  • 16specifications compared
  • 13differ
  • 3identical
  • 3known for one product only

Key differences

  • Input connection type
    • BASIC RACK DISTRIBUTION PANEL 230 V IN A RACK:IEC 309
    • RackPDU, Metered, ZeroU, 16A, 230V, (20)C13 & (4)C19; IEC C20:IEC-320 C20
  • Nominal input voltage
    • BASIC RACK DISTRIBUTION PANEL 230 V IN A RACK:400 V
    • RackPDU, Metered, ZeroU, 16A, 230V, (20)C13 & (4)C19; IEC C20:230 V
  • Operating temperature (T-T)
    • BASIC RACK DISTRIBUTION PANEL 230 V IN A RACK:0 - 40 °C
    • RackPDU, Metered, ZeroU, 16A, 230V, (20)C13 & (4)C19; IEC C20:0 - 45 °C
  • Storage temperature (T-T)
    • BASIC RACK DISTRIBUTION PANEL 230 V IN A RACK:-15 - 45 °C
    • RackPDU, Metered, ZeroU, 16A, 230V, (20)C13 & (4)C19; IEC C20:-25 - 65 °C
  • Width
    • BASIC RACK DISTRIBUTION PANEL 230 V IN A RACK:610 mm
    • RackPDU, Metered, ZeroU, 16A, 230V, (20)C13 & (4)C19; IEC C20:56 mm
  • Depth
    • BASIC RACK DISTRIBUTION PANEL 230 V IN A RACK:1067 mm
    • RackPDU, Metered, ZeroU, 16A, 230V, (20)C13 & (4)C19; IEC C20:44 mm
  • Height
    • BASIC RACK DISTRIBUTION PANEL 230 V IN A RACK:2070 mm
    • RackPDU, Metered, ZeroU, 16A, 230V, (20)C13 & (4)C19; IEC C20:1619 mm
  • Weight
    • BASIC RACK DISTRIBUTION PANEL 230 V IN A RACK:272.7 kg
    • RackPDU, Metered, ZeroU, 16A, 230V, (20)C13 & (4)C19; IEC C20:4.32 kg

Side by side

Differences highlightedShow differences only (on)
Comparison of BASIC RACK DISTRIBUTION PANEL 230 V IN A RACK, RackPDU, Metered, ZeroU, 16A, 230V, (20)C13 & (4)C19; IEC C20
19 specifications
Ports & interfaces2 differ
Input connection typeDiffersIEC 309IEC-320 C20
Output connectionsKnown for oneUnknown — not stated by the source(20) IEC 320 C13 (4) IEC 320 C19
I/O portsDiffersIEC 309(20) IEC 320 C13 (4) IEC 320 C19 IEC-320 C20
Power1 differ
Nominal input voltageDiffers400 V230 V
Nominal output voltageKnown for oneUnknown — not stated by the source230 V
Output voltageKnown for oneUnknown — not stated by the source230 V
Operational conditions2 differ
Operating temperature (T-T)Differs0 - 40 °C0 - 45 °C
Storage temperature (T-T)Differs-15 - 45 °C-25 - 65 °C
Weight & dimensions4 differ
WidthDiffers610 mm56 mm
DepthDiffers1067 mm44 mm
HeightDiffers2070 mm1619 mm
WeightDiffers272.7 kg4.32 kg
Packaging data4 differ
Package weightDiffers295.4 kg7.73 kg
Package widthDiffers914 mm152 mm
Package depthDiffers1219 mm127 mm
Package heightDiffers2261 mm2134 mm

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.