Product comparison · 2 power distribution units (pdus)

APC APDU11452ME power distribution unit (PDU) 42 AC outlet(s) 0U Black vs Vertiv MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black

Add a product
  • 17specifications compared
  • 12differ
  • 5identical
  • 17known for one product only

Key differences

The Vertiv MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black has 2 U more rack capacity than the APC APDU11452ME power distribution unit (PDU) 42 AC outlet(s) 0U Black (2U vs 0U). The Vertiv MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black has 32 V more nominal output voltage than the APC APDU11452ME power distribution unit (PDU) 42 AC outlet(s) 0U Black (240 V vs 208 V). The Vertiv MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black has 17,200 VA more load capacity than the APC APDU11452ME power distribution unit (PDU) 42 AC outlet(s) 0U Black (34500 VA vs 17300 VA). PDU types: Metered on the APC APDU11452ME power distribution unit (PDU) 42 AC outlet(s) 0U Black, Monitored on the Vertiv MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black. Mounting: Vertical on the APC APDU11452ME power distribution unit (PDU) 42 AC outlet(s) 0U Black, Horizontal on the Vertiv MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black.

  • PDU types
    • APDU11452ME power distribution unit (PDU) 42 AC outlet(s) 0U Black:Metered
    • MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black:Monitored
  • Rack capacity
    • APDU11452ME power distribution unit (PDU) 42 AC outlet(s) 0U Black:0U
    • MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black:2U
  • Mounting
    • APDU11452ME power distribution unit (PDU) 42 AC outlet(s) 0U Black:Vertical
    • MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black:Horizontal
  • AC outlets quantity
    • APDU11452ME power distribution unit (PDU) 42 AC outlet(s) 0U Black:42 AC outlet(s)
    • MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black:24 AC outlet(s)
  • Nominal input voltage
    • APDU11452ME power distribution unit (PDU) 42 AC outlet(s) 0U Black:200 - 240 V
    • MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black:200 - 415 V
  • Nominal output voltage
    • APDU11452ME power distribution unit (PDU) 42 AC outlet(s) 0U Black:208 V
    • MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black:240 V
  • Load capacity
    • APDU11452ME power distribution unit (PDU) 42 AC outlet(s) 0U Black:17300 VA
    • MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black:34500 VA
  • Maximum power
    • APDU11452ME power distribution unit (PDU) 42 AC outlet(s) 0U Black:17300 W
    • MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black:34500 W

Side by side

Differences highlightedShow differences only (off)
Comparison of APDU11452ME, MN05MDR1-18I6B3-6PS56B0F10-S
34 specifications
Design3 differ
PDU typesDiffersMeteredMonitored
TypeKnown for oneUnknown — not stated by the sourceThree-phase
Rack capacityDiffers0U2U
MountingDiffersVerticalHorizontal
Product colourBlackBlack
DisplayKnown for oneUnknown — not stated by the sourceLCD
Ports & interfaces1 differ
AC outlets quantityDiffers42 AC outlet(s)24 AC outlet(s)
AC outlet typesC13 coupler, C19 couplerC13 coupler, C19 coupler
Ethernet LAN (RJ-45) portsKnown for oneUnknown — not stated by the source2
Featuresidentical
Daisy chainKnown for oneUnknown — not stated by the sourceYes
Reset buttonKnown for oneUnknown — not stated by the sourceYes
Cable length3 m3 m
Management featuresidentical
MonitoringKnown for oneUnknown — not stated by the sourceCurrent, Power, Voltage
Supported network protocolsKnown for oneUnknown — not stated by the sourceDHCP, HTTP, HTTPS, IPv4, IPv6, LDAP, NTP, RADIUS, RSTP, SSH, SMTP, SNMP (v1/v2c/v3), Syslog, TACACS+, Modbus TCP
Power4 differ
Nominal input voltageDiffers200 - 240 V200 - 415 V
AC input frequency50/60 Hz50/60 Hz
Maximum current60 A60 A
Nominal output voltageDiffers208 V240 V
Load capacityDiffers17300 VA34500 VA
Maximum powerDiffers17300 W34500 W
Power protection featuresKnown for oneUnknown — not stated by the sourceOver current
Output voltageKnown for one208 VUnknown — not stated by the source
Certificatesidentical
Compliance certificatesKnown for oneUnknown — not stated by the sourceCE, cUL, UL, UKCA, RoHS, RCM, Federal Communications Commission (FCC), China RoHS
Weight & dimensions4 differ
WidthDiffers56 mm435 mm
DepthDiffers75 mm740 mm
HeightDiffers1780 mm88 mm
WeightDiffers10.7 kg11.3 kg
Operational conditionsidentical
Operating temperature (T-T)Known for one-5 - 60 °FUnknown — not stated by the source
Operating temperature (charge) (T-T)Known for one-25 - 65 °CUnknown — not stated by the source
Operating relative humidity (H-H)Known for one5 - 95%Unknown — not stated by the source
Packaging dataidentical
Package weightKnown for one13.7 kgUnknown — not stated by the source
Package widthKnown for one132 mmUnknown — not stated by the source
Package depthKnown for one262 mmUnknown — not stated by the source
Package heightKnown for one1980 mmUnknown — not stated by the source

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.