Product comparison · 2 power distribution units (pdus)

APC APDU11451SW power distribution unit (PDU) 42 AC outlet(s) 0U Black vs APC NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets

Add a product
  • 20specifications compared
  • 16differ
  • 4identical
  • 25known for one product only

Key differences

The APC NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets has 60 A more maximum current than the APC APDU11451SW power distribution unit (PDU) 42 AC outlet(s) 0U Black (100 A vs 40 A). The APC NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets has 54,600 VA more load capacity than the APC APDU11451SW power distribution unit (PDU) 42 AC outlet(s) 0U Black (69000 VA vs 14400 VA). The APC NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets has 3 mm more width than the APC APDU11451SW power distribution unit (PDU) 42 AC outlet(s) 0U Black (59 mm vs 56 mm). PDU types: Switched on the APC APDU11451SW power distribution unit (PDU) 42 AC outlet(s) 0U Black, Metered on the APC NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets. AC outlets quantity: 42 AC outlet(s) on the APC APDU11451SW power distribution unit (PDU) 42 AC outlet(s) 0U Black, 18 AC outlet(s) on the APC NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets.

  • PDU types
    • APDU11451SW power distribution unit (PDU) 42 AC outlet(s) 0U Black:Switched
    • NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets:Metered
  • AC outlets quantity
    • APDU11451SW power distribution unit (PDU) 42 AC outlet(s) 0U Black:42 AC outlet(s)
    • NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets:18 AC outlet(s)
  • Nominal input voltage
    • APDU11451SW power distribution unit (PDU) 42 AC outlet(s) 0U Black:200 - 240 V
    • NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets:415 3 phases
  • Maximum current
    • APDU11451SW power distribution unit (PDU) 42 AC outlet(s) 0U Black:40 A
    • NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets:100 A
  • Output voltage
    • APDU11451SW power distribution unit (PDU) 42 AC outlet(s) 0U Black:208 V
    • NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets:415 V AC 3 phases
  • Load capacity
    • APDU11451SW power distribution unit (PDU) 42 AC outlet(s) 0U Black:14400 VA
    • NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets:69000 VA
  • Operating temperature (T-T)
    • APDU11451SW power distribution unit (PDU) 42 AC outlet(s) 0U Black:-5 - 60 °F
    • NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets:-5 - 60 °C
  • Operating relative humidity (H-H)
    • APDU11451SW power distribution unit (PDU) 42 AC outlet(s) 0U Black:5 - 95%
    • NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets:5 - 90%

Side by side

Differences highlightedShow differences only (on)
Comparison of APDU11451SW, NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets
45 specifications
Design1 differ
PDU typesDiffersSwitchedMetered
TypeKnown for oneUnknown — not stated by the sourceThree-phase
UpgradeableKnown for oneUnknown — not stated by the sourceYes
Ports & interfaces2 differ
AC outlets quantityDiffers42 AC outlet(s)18 AC outlet(s)
Power plugKnown for oneUnknown — not stated by the sourceIEC309
AC outlet typesDiffersC13 coupler, C19 couplerC13 coupler, C15 coupler, C19 coupler, C21 coupler
Input connection typeKnown for oneUnknown — not stated by the sourceIEC 309 100 A
Featuresidentical
International Protection (IP) codeKnown for oneUnknown — not stated by the sourceIP67
Cable lengthKnown for one3 mUnknown — not stated by the source
Management featuresidentical
Management platformKnown for oneUnknown — not stated by the sourceNMC3
Power4 differ
Nominal input voltageDiffers200 - 240 V415 3 phases
Maximum currentDiffers40 A100 A
Output voltageDiffers208 V415 V AC 3 phases
Load capacityDiffers14400 VA69000 VA
Number of phasesKnown for oneUnknown — not stated by the source3
AC input frequencyKnown for one50/60 HzUnknown — not stated by the source
Nominal output voltageKnown for one208 VUnknown — not stated by the source
Maximum powerKnown for one14400 WUnknown — not stated by the source
Certificatesidentical
Compliance certificatesKnown for oneUnknown — not stated by the sourceRoHS, REACH, WEEE
Waste Electrical and Electronic Equipment (WEEE) complianceKnown for oneUnknown — not stated by the sourceYes
Sustainabilityidentical
Doesn't containKnown for oneUnknown — not stated by the sourceSilicone
Operational conditions2 differ
Operating temperature (T-T)Differs-5 - 60 °F-5 - 60 °C
Storage temperature (T-T)Known for oneUnknown — not stated by the source-20 - 60 °C
Operating relative humidity (H-H)Differs5 - 95%5 - 90%
Storage relative humidity (H-H)Known for oneUnknown — not stated by the source5 - 95%
Non-operating altitudeKnown for oneUnknown — not stated by the source0 - 15240 m
Operating temperature (charge) (T-T)Known for one-25 - 65 °CUnknown — not stated by the source
Weight & dimensions4 differ
WidthDiffers56 mm59 mm
DepthDiffers75 mm87 mm
HeightDiffers1826 mm1750 mm
WeightDiffers11.2 kg18.8 kg
Packaging data3 differ
Package weightDiffers14.2 kg24.6 kg
Package widthDiffers132 mm350 mm
Package depthDiffers262 mm165 mm
Technical detailsidentical
Packaging recycled materialsKnown for oneUnknown — not stated by the sourceRecycled cardboard
Preferred mounting positionKnown for oneUnknown — not stated by the sourceno preference
Packaging without single use plasticKnown for oneUnknown — not stated by the sourceYes
SCIP numberKnown for oneUnknown — not stated by the source7547f066-9302-46d9-96e9-461928dd6901
Sustainable packagingKnown for oneUnknown — not stated by the sourceNo
Take-back systemKnown for oneUnknown — not stated by the sourceNo
Logistics dataidentical
Customs product code (TARIC)Known for oneUnknown — not stated by the source8537109899

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.

More power distribution units (pdus) comparisons

All power distribution units (pdus) comparisons