Product comparison · 2 power distribution units (pdus)

APC APDU11451SW power distribution unit (PDU) 42 AC outlet(s) 0U Black vs APC NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets

Add a product
  • 21specifications compared
  • 14differ
  • 7identical
  • 11known for one product only

Key differences

The APC NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets has 60 A more maximum current than the APC APDU11451SW power distribution unit (PDU) 42 AC outlet(s) 0U Black (100 A vs 40 A). The APC NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets has 14,400 VA more load capacity than the APC APDU11451SW power distribution unit (PDU) 42 AC outlet(s) 0U Black (28800 VA vs 14400 VA). The APC NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets has 74 mm more height than the APC APDU11451SW power distribution unit (PDU) 42 AC outlet(s) 0U Black (1900 mm vs 1826 mm). PDU types: Switched on the APC APDU11451SW power distribution unit (PDU) 42 AC outlet(s) 0U Black, Metered on the APC NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets. AC outlets quantity: 42 AC outlet(s) on the APC APDU11451SW power distribution unit (PDU) 42 AC outlet(s) 0U Black, 30 AC outlet(s) on the APC NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets.

  • PDU types
    • APDU11451SW power distribution unit (PDU) 42 AC outlet(s) 0U Black:Switched
    • NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets:Metered
  • AC outlets quantity
    • APDU11451SW power distribution unit (PDU) 42 AC outlet(s) 0U Black:42 AC outlet(s)
    • NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets:30 AC outlet(s)
  • Nominal input voltage
    • APDU11451SW power distribution unit (PDU) 42 AC outlet(s) 0U Black:200 - 240 V
    • NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets:208 V
  • Maximum current
    • APDU11451SW power distribution unit (PDU) 42 AC outlet(s) 0U Black:40 A
    • NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets:100 A
  • Load capacity
    • APDU11451SW power distribution unit (PDU) 42 AC outlet(s) 0U Black:14400 VA
    • NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets:28800 VA
  • Operating temperature (T-T)
    • APDU11451SW power distribution unit (PDU) 42 AC outlet(s) 0U Black:-5 - 60 °F
    • NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets:-5 - 60 °C
  • Operating relative humidity (H-H)
    • APDU11451SW power distribution unit (PDU) 42 AC outlet(s) 0U Black:5 - 95%
    • NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets:5 - 90%
  • Height
    • APDU11451SW power distribution unit (PDU) 42 AC outlet(s) 0U Black:1826 mm
    • NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets:1900 mm

Side by side

Differences highlightedShow differences only (on)
Comparison of APDU11451SW, NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets
32 specifications
Design1 differ
PDU typesDiffersSwitchedMetered
TypeKnown for oneUnknown — not stated by the sourceThree-phase
Ports & interfaces2 differ
AC outlets quantityDiffers42 AC outlet(s)30 AC outlet(s)
Power plugKnown for oneUnknown — not stated by the sourceIEC 60309
AC outlet typesDiffersC13 coupler, C19 couplerC15 coupler, C13 coupler, C19 coupler, C21 coupler
Featuresidentical
International Protection (IP) codeKnown for oneUnknown — not stated by the sourceIP67
Cable lengthKnown for one3 mUnknown — not stated by the source
Management featuresidentical
Management platformKnown for oneUnknown — not stated by the sourceNMC3
Power3 differ
Nominal input voltageDiffers200 - 240 V208 V
Maximum currentDiffers40 A100 A
Load capacityDiffers14400 VA28800 VA
Nominal output voltageKnown for one208 VUnknown — not stated by the source
Maximum powerKnown for one14400 WUnknown — not stated by the source
Operational conditions2 differ
Operating temperature (T-T)Differs-5 - 60 °F-5 - 60 °C
Storage temperature (T-T)Known for oneUnknown — not stated by the source-20 - 60 °C
Operating relative humidity (H-H)Differs5 - 95%5 - 90%
Storage relative humidity (H-H)Known for oneUnknown — not stated by the source5 - 95%
Non-operating altitudeKnown for oneUnknown — not stated by the source0 - 15240 m
Operating temperature (charge) (T-T)Known for one-25 - 65 °CUnknown — not stated by the source
Weight & dimensions2 differ
HeightDiffers1826 mm1900 mm
WeightDiffers11.2 kg14 kg
Packaging data4 differ
Package weightDiffers14.2 kg19.8 kg
Package widthDiffers132 mm350 mm
Package depthDiffers262 mm165 mm
Package heightDiffers1980 mm2110 mm

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.