Product comparison · 2 power distribution units (pdus)

APC APDU11351SW power distribution unit (PDU) 48 AC outlet(s) 0U Black vs Vertiv MN00X1R1-16MCQ9-3TL14A0A10-S power distribution unit (PDU) 16 AC outlet(s) 1U Black

Add a product
  • 17specifications compared
  • 12differ
  • 5identical
  • 11known for one product only

Key differences

The Vertiv MN00X1R1-16MCQ9-3TL14A0A10-S power distribution unit (PDU) 16 AC outlet(s) 1U Black has 1 U more rack capacity than the APC APDU11351SW power distribution unit (PDU) 48 AC outlet(s) 0U Black (1U vs 0U). The APC APDU11351SW power distribution unit (PDU) 48 AC outlet(s) 0U Black has 100 - 240 V more nominal input voltage than the Vertiv MN00X1R1-16MCQ9-3TL14A0A10-S power distribution unit (PDU) 16 AC outlet(s) 1U Black (200 - 240 V vs 100 - 240 V). The APC APDU11351SW power distribution unit (PDU) 48 AC outlet(s) 0U Black has 2,900 VA more load capacity than the Vertiv MN00X1R1-16MCQ9-3TL14A0A10-S power distribution unit (PDU) 16 AC outlet(s) 1U Black (8600 VA vs 5700 VA). PDU types: Switched on the APC APDU11351SW power distribution unit (PDU) 48 AC outlet(s) 0U Black, Basic on the Vertiv MN00X1R1-16MCQ9-3TL14A0A10-S power distribution unit (PDU) 16 AC outlet(s) 1U Black. Mounting: Vertical on the APC APDU11351SW power distribution unit (PDU) 48 AC outlet(s) 0U Black, Horizontal on the Vertiv MN00X1R1-16MCQ9-3TL14A0A10-S power distribution unit (PDU) 16 AC outlet(s) 1U Black.

  • PDU types
    • APDU11351SW power distribution unit (PDU) 48 AC outlet(s) 0U Black:Switched
    • MN00X1R1-16MCQ9-3TL14A0A10-S power distribution unit (PDU) 16 AC outlet(s) 1U Black:Basic
  • Rack capacity
    • APDU11351SW power distribution unit (PDU) 48 AC outlet(s) 0U Black:0U
    • MN00X1R1-16MCQ9-3TL14A0A10-S power distribution unit (PDU) 16 AC outlet(s) 1U Black:1U
  • Mounting
    • APDU11351SW power distribution unit (PDU) 48 AC outlet(s) 0U Black:Vertical
    • MN00X1R1-16MCQ9-3TL14A0A10-S power distribution unit (PDU) 16 AC outlet(s) 1U Black:Horizontal
  • AC outlets quantity
    • APDU11351SW power distribution unit (PDU) 48 AC outlet(s) 0U Black:48 AC outlet(s)
    • MN00X1R1-16MCQ9-3TL14A0A10-S power distribution unit (PDU) 16 AC outlet(s) 1U Black:16 AC outlet(s)
  • AC outlet types
    • APDU11351SW power distribution unit (PDU) 48 AC outlet(s) 0U Black:C13 coupler, C19 coupler
    • MN00X1R1-16MCQ9-3TL14A0A10-S power distribution unit (PDU) 16 AC outlet(s) 1U Black:NEMA 5-20R, C13 coupler
  • Nominal input voltage
    • APDU11351SW power distribution unit (PDU) 48 AC outlet(s) 0U Black:200 - 240 V
    • MN00X1R1-16MCQ9-3TL14A0A10-S power distribution unit (PDU) 16 AC outlet(s) 1U Black:100 - 240 V
  • Load capacity
    • APDU11351SW power distribution unit (PDU) 48 AC outlet(s) 0U Black:8600 VA
    • MN00X1R1-16MCQ9-3TL14A0A10-S power distribution unit (PDU) 16 AC outlet(s) 1U Black:5700 VA
  • Maximum power
    • APDU11351SW power distribution unit (PDU) 48 AC outlet(s) 0U Black:8600 W
    • MN00X1R1-16MCQ9-3TL14A0A10-S power distribution unit (PDU) 16 AC outlet(s) 1U Black:5700 W

Side by side

Differences highlightedShow differences only (off)
Comparison of APDU11351SW, MN00X1R1-16MCQ9-3TL14A0A10-S
28 specifications
Design3 differ
PDU typesDiffersSwitchedBasic
Rack capacityDiffers0U1U
MountingDiffersVerticalHorizontal
Product colourBlackBlack
On/off switchKnown for oneUnknown — not stated by the sourceYes
Ports & interfaces2 differ
AC outlets quantityDiffers48 AC outlet(s)16 AC outlet(s)
AC outlet typesDiffersC13 coupler, C19 couplerNEMA 5-20R, C13 coupler
Power plugKnown for oneUnknown — not stated by the sourceNEMA L14-30P
Featuresidentical
Cable length3 m3 m
Power3 differ
Nominal input voltageDiffers200 - 240 V100 - 240 V
AC input frequency50/60 Hz50/60 Hz
Maximum current30 A30 A
Nominal output voltage208 V208 V
Output voltageKnown for one208 VUnknown — not stated by the source
Load capacityDiffers8600 VA5700 VA
Maximum powerDiffers8600 W5700 W
Operational conditionsidentical
Operating temperature (T-T)Known for one-5 - 60 °FUnknown — not stated by the source
Operating temperature (charge) (T-T)Known for one-25 - 65 °CUnknown — not stated by the source
Operating relative humidity (H-H)Known for one5 - 95%Unknown — not stated by the source
Weight & dimensions4 differ
WidthDiffers56 mm50.8 mm
DepthDiffers75 mm50.8 mm
HeightDiffers1780 mm1682.7 mm
WeightDiffers9.4 kg6.8 kg
Packaging dataidentical
Package weightKnown for one12.4 kgUnknown — not stated by the source
Package widthKnown for one116 mmUnknown — not stated by the source
Package depthKnown for one208 mmUnknown — not stated by the source
Package heightKnown for one1980 mmUnknown — not stated by the source
Certificatesidentical
Compliance certificatesKnown for oneUnknown — not stated by the sourceTrade Agreements Act (TAA), UL, cUL, RoHS

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.

More power distribution units (pdus) comparisons