Product comparison · 2 power distribution units (pdus)

APC AP8981X633 power distribution unit (PDU) 24 AC outlet(s) 0U Black vs Fujitsu S26361-F5560-E210 power distribution unit (PDU) 19 AC outlet(s) 0U Black

Add a product
  • 12specifications compared
  • 5differ
  • 7identical
  • 18known for one product only

Key differences

  • PDU types
    • AP8981X633 power distribution unit (PDU) 24 AC outlet(s) 0U Black:Switched
    • S26361-F5560-E210 power distribution unit (PDU) 19 AC outlet(s) 0U Black:Metered
  • AC outlets quantity
    • AP8981X633 power distribution unit (PDU) 24 AC outlet(s) 0U Black:24 AC outlet(s)
    • S26361-F5560-E210 power distribution unit (PDU) 19 AC outlet(s) 0U Black:19 AC outlet(s)
  • Nominal input voltage
    • AP8981X633 power distribution unit (PDU) 24 AC outlet(s) 0U Black:208 V
    • S26361-F5560-E210 power distribution unit (PDU) 19 AC outlet(s) 0U Black:200 - 240 V
  • Operating temperature (T-T)
    • AP8981X633 power distribution unit (PDU) 24 AC outlet(s) 0U Black:23 - 113 °F
    • S26361-F5560-E210 power distribution unit (PDU) 19 AC outlet(s) 0U Black:0 - 60 °C
  • Storage temperature (T-T)
    • AP8981X633 power distribution unit (PDU) 24 AC outlet(s) 0U Black:-25 - 65 °C
    • S26361-F5560-E210 power distribution unit (PDU) 19 AC outlet(s) 0U Black:-25 - 85 °C

Side by side

Differences highlightedShow differences only (off)
Comparison of AP8981X633, S26361-F5560-E210
30 specifications
Design1 differ
PDU typesDiffersSwitchedMetered
TypeKnown for oneUnknown — not stated by the sourceSingle-phase
Rack capacity0U0U
MountingVerticalVertical
Product colourBlackBlack
DisplayKnown for oneUnknown — not stated by the sourceLCD
Ports & interfaces1 differ
AC outlets quantityDiffers24 AC outlet(s)19 AC outlet(s)
Power plugKnown for oneUnknown — not stated by the sourceIEC309
AC outlet typesC13 coupler, C19 couplerC13 coupler, C19 coupler
Output connectionsKnown for oneUnknown — not stated by the source17x IEC320 C13 (10A) + 2xIEC320 C19 (16A)
Featuresidentical
LED indicatorsKnown for oneUnknown — not stated by the sourceYes
Security algorithmsKnown for oneUnknown — not stated by the source802.1x RADIUS, AES, DES, MD5
Cable lengthKnown for one3.6 mUnknown — not stated by the source
Management featuresidentical
Management protocolsKnown for oneUnknown — not stated by the sourceSNMP v1/v2/v3
Supported network protocolsKnown for oneUnknown — not stated by the sourceLDAP, TACACS, Radius, Kerberos
Power1 differ
Nominal input voltageDiffers208 V200 - 240 V
Maximum current16 A16 A
Block 1 output currentKnown for oneUnknown — not stated by the source10 A
Block 2 output currentKnown for oneUnknown — not stated by the source16 A
AC input frequencyKnown for one50 - 60 HzUnknown — not stated by the source
Nominal output voltageKnown for one400 VUnknown — not stated by the source
Maximum powerKnown for one11000 WUnknown — not stated by the source
Certificatesidentical
Compliance certificatesRoHSRoHS
CertificationKnown for oneUnknown — not stated by the sourceBV-BG,CB,CE
Operational conditions2 differ
Operating temperature (T-T)Differs23 - 113 °F0 - 60 °C
Storage temperature (T-T)Differs-25 - 65 °C-25 - 85 °C
Operating relative humidity (H-H)5 - 95%5 - 95%
Storage relative humidity (H-H)Known for one5 - 95%Unknown — not stated by the source
Operating altitudeKnown for one0 - 3000 mUnknown — not stated by the source
Packaging contentidentical
Cables includedKnown for oneACUnknown — not stated by the source

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.