Product comparison · 2 power distribution units (pdus)

APC NetShelter Metered Rack PDU, 0U, 3PH, 22kW vs APC MXA108 power distribution unit (PDU) 8 AC outlet(s) Black

Add a product
  • 26specifications compared
  • 21differ
  • 5identical
  • 11known for one product only

Key differences

  • PDU types
    • NetShelter Metered Rack PDU, 0U, 3PH, 22kW:Metered
    • MXA108 power distribution unit (PDU) 8 AC outlet(s) Black:Basic
  • AC outlets quantity
    • NetShelter Metered Rack PDU, 0U, 3PH, 22kW:42 AC outlet(s)
    • MXA108 power distribution unit (PDU) 8 AC outlet(s) Black:8 AC outlet(s)
  • AC outlet types
    • NetShelter Metered Rack PDU, 0U, 3PH, 22kW:C13 coupler, C19 coupler
    • MXA108 power distribution unit (PDU) 8 AC outlet(s) Black:NEMA L14-30R
  • Cable length
    • NetShelter Metered Rack PDU, 0U, 3PH, 22kW:1.83 m
    • MXA108 power distribution unit (PDU) 8 AC outlet(s) Black:1.22 m
  • Nominal input voltage
    • NetShelter Metered Rack PDU, 0U, 3PH, 22kW:400 V
    • MXA108 power distribution unit (PDU) 8 AC outlet(s) Black:230 V
  • Maximum current
    • NetShelter Metered Rack PDU, 0U, 3PH, 22kW:32 A
    • MXA108 power distribution unit (PDU) 8 AC outlet(s) Black:30 A
  • Load capacity
    • NetShelter Metered Rack PDU, 0U, 3PH, 22kW:22080 VA
    • MXA108 power distribution unit (PDU) 8 AC outlet(s) Black:7500 VA
  • Operating temperature (T-T)
    • NetShelter Metered Rack PDU, 0U, 3PH, 22kW:0 - 55 °C
    • MXA108 power distribution unit (PDU) 8 AC outlet(s) Black:0 - 45 °C

Side by side

Differences highlightedShow differences only (off)
Comparison of AP8886, MXA108
37 specifications
Design1 differ
PDU typesDiffersMeteredBasic
Rack capacityKnown for one0UUnknown — not stated by the source
MountingVerticalVertical
Product colourBlackBlack
Ports & interfaces3 differ
AC outlets quantityDiffers42 AC outlet(s)8 AC outlet(s)
Power plugKnown for oneIEC309Unknown — not stated by the source
AC outlet typesDiffersC13 coupler, C19 couplerNEMA L14-30R
Output connectionsDiffers30 x IEC 320 C13 12 x IEC 320 C19L5-15R
Input connection typeKnown for oneUnknown — not stated by the sourceL14-30P
Features1 differ
LED indicatorsKnown for oneYesUnknown — not stated by the source
Cable lengthDiffers1.83 m1.22 m
Management featuresidentical
MonitoringKnown for oneCurrent, Power, VoltageUnknown — not stated by the source
Power3 differ
Nominal input voltageDiffers400 V230 V
AC input frequency50 - 60 Hz50 - 60 Hz
Maximum currentDiffers32 A30 A
Nominal output voltageKnown for one230 VUnknown — not stated by the source
Load capacityDiffers22080 VA7500 VA
Maximum input current per phaseKnown for one32 AUnknown — not stated by the source
Maximum powerKnown for one22000 WUnknown — not stated by the source
Power protection featuresKnown for oneOverloadUnknown — not stated by the source
Certificates1 differ
Compliance certificatesKnown for oneRoHSUnknown — not stated by the source
CertificationDiffersEN 55022 A,EN 55024, EN 61000-3-2, EN 61000-3-3, FCC 15 A, ICES-003, VCCI A, VDE REACH: No SVHCsCSA, UL 1778, UL Listed
Operational conditions4 differ
Operating temperature (T-T)Differs0 - 55 °C0 - 45 °C
Storage temperature (T-T)Differs-25 - 65 °C-15 - 45 °C
Operating relative humidity (H-H)Differs5 - 95%0 - 95%
Storage relative humidity (H-H)Differs5 - 95%0 - 95%
Operating altitude0 - 3000 m0 - 3000 m
Non-operating altitude0 - 15000 m0 - 15000 m
Weight & dimensions4 differ
WidthDiffers56 mm213 mm
DepthDiffers51 mm222 mm
HeightDiffers1829 mm95 mm
WeightDiffers8.72 kg3.4 kg
Packaging data4 differ
Package weightDiffers11.6 kg3.64 kg
Package widthDiffers170 mm279 mm
Package depthDiffers112 mm222 mm
Package heightDiffers2050 mm305 mm
Logistics dataidentical
Total carbon footprint (kg of CO2e)Known for one57837.86Unknown — not stated by the source

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.

More power distribution units (pdus) comparisons

All power distribution units (pdus) comparisons