Product comparison · 2 power distribution units (pdus)

APC AP8867 power distribution unit (PDU) 30 AC outlet(s) 0U Black vs APC AP8868 power distribution unit (PDU) 42 AC outlet(s) 0U Black

Add a product
  • 31specifications compared
  • 13differ
  • 18identical
  • 5known for one product only

Key differences

  • Mounting
    • AP8867 power distribution unit (PDU) 30 AC outlet(s) 0U Black:Horizontal/Vertical
    • AP8868 power distribution unit (PDU) 42 AC outlet(s) 0U Black:Vertical
  • AC outlets quantity
    • AP8867 power distribution unit (PDU) 30 AC outlet(s) 0U Black:30 AC outlet(s)
    • AP8868 power distribution unit (PDU) 42 AC outlet(s) 0U Black:42 AC outlet(s)
  • Input connection type
    • AP8867 power distribution unit (PDU) 30 AC outlet(s) 0U Black:IEC 309 60A 3P+PE
    • AP8868 power distribution unit (PDU) 42 AC outlet(s) 0U Black:CS8365
  • Load capacity
    • AP8867 power distribution unit (PDU) 30 AC outlet(s) 0U Black:17300 VA
    • AP8868 power distribution unit (PDU) 42 AC outlet(s) 0U Black:10000 VA
  • Maximum input current per phase
    • AP8867 power distribution unit (PDU) 30 AC outlet(s) 0U Black:48 A
    • AP8868 power distribution unit (PDU) 42 AC outlet(s) 0U Black:35 A
  • Maximum total current draw per phase
    • AP8867 power distribution unit (PDU) 30 AC outlet(s) 0U Black:48 A
    • AP8868 power distribution unit (PDU) 42 AC outlet(s) 0U Black:35 A
  • Operating relative humidity (H-H)
    • AP8867 power distribution unit (PDU) 30 AC outlet(s) 0U Black:0 - 95%
    • AP8868 power distribution unit (PDU) 42 AC outlet(s) 0U Black:5 - 95%
  • Weight
    • AP8867 power distribution unit (PDU) 30 AC outlet(s) 0U Black:10.2 kg
    • AP8868 power distribution unit (PDU) 42 AC outlet(s) 0U Black:8.52 kg

Side by side

Differences highlightedShow differences only (off)
Comparison of AP8867, AP8868
36 specifications
Design1 differ
PDU typesMeteredMetered
Rack capacity0U0U
MountingDiffersHorizontal/VerticalVertical
Product colourBlackBlack
DisplayKnown for oneLCDUnknown — not stated by the source
Ports & interfaces2 differ
AC outlets quantityDiffers30 AC outlet(s)42 AC outlet(s)
AC outlet typesKnown for oneC13 couplerUnknown — not stated by the source
Input connection typeDiffersIEC 309 60A 3P+PECS8365
Output connectionsKnown for oneUnknown — not stated by the source36 x IEC 320 C13 6 x IEC 320 C19
Featuresidentical
Cable length1.83 m1.83 m
Power3 differ
Nominal input voltage208 V208 V
AC input frequency50 - 60 Hz50 - 60 Hz
Maximum currentKnown for one60 AUnknown — not stated by the source
Nominal output voltage208 V208 V
Output voltageKnown for one208 VUnknown — not stated by the source
Load capacityDiffers17300 VA10000 VA
Maximum input current per phaseDiffers48 A35 A
Maximum total current draw per phaseDiffers48 A35 A
Power protection featuresOverloadOverload
Certificates1 differ
Compliance certificatesRoHSRoHS
CertificationDifferscUL, EN 55022 A, EN 55024, EN 61000-3-2, EN 61000-3-3, FCC-15 A, UL, VCCI AcUL, EN 55022, EN 55024, EN 61000-3-2, EN 61000-3-3, FCC, ICES-003, UL, VCCI
Operational conditions1 differ
Operating temperature (T-T)0 - 55 °C0 - 55 °C
Storage temperature (T-T)-25 - 65 °C-25 - 65 °C
Operating relative humidity (H-H)Differs0 - 95%5 - 95%
Storage relative humidity (H-H)5 - 95%5 - 95%
Operating altitude0 - 3000 m0 - 3000 m
Non-operating altitude0 - 15000 m0 - 15000 m
Weight & dimensions1 differ
Width56 mm56 mm
Depth51 mm51 mm
Height1829 mm1829 mm
WeightDiffers10.2 kg8.52 kg
Packaging data3 differ
Package weightDiffers14.1 kg11.4 kg
Package widthDiffers221 mm170 mm
Package depth112 mm112 mm
Package heightDiffers2149 mm2050 mm
Logistics data1 differ
Total carbon footprint (kg of CO2e)Differs59943.9851678.25

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.