Product comparison · 2 power distribution units (pdus)

APC AP8861US power distribution unit (PDU) 44 AC outlet(s) 0U Black vs ATEN 30A/32A 24-Outlet Outlet-Metered & Switched eco PDU

Add a product
  • 20specifications compared
  • 19differ
  • 1identical
  • 27known for one product only

Key differences

The APC AP8861US power distribution unit (PDU) 44 AC outlet(s) 0U Black has 0.22 m more cable length than the ATEN 30A/32A 24-Outlet Outlet-Metered & Switched eco PDU (1.82 m vs 1.6 m). The ATEN 30A/32A 24-Outlet Outlet-Metered & Switched eco PDU has 12 A more maximum current than the APC AP8861US power distribution unit (PDU) 44 AC outlet(s) 0U Black (32 A vs 20 A). The ATEN 30A/32A 24-Outlet Outlet-Metered & Switched eco PDU has 1,660 VA more load capacity than the APC AP8861US power distribution unit (PDU) 44 AC outlet(s) 0U Black (7360 VA vs 5700 VA). PDU types: Metered on the APC AP8861US power distribution unit (PDU) 44 AC outlet(s) 0U Black, Metered, Switched on the ATEN 30A/32A 24-Outlet Outlet-Metered & Switched eco PDU. AC outlets quantity: 44 AC outlet(s) on the APC AP8861US power distribution unit (PDU) 44 AC outlet(s) 0U Black, 24 AC outlet(s) on the ATEN 30A/32A 24-Outlet Outlet-Metered & Switched eco PDU.

  • PDU types
    • AP8861US power distribution unit (PDU) 44 AC outlet(s) 0U Black:Metered
    • 30A/32A 24-Outlet Outlet-Metered & Switched eco PDU:Metered, Switched
  • AC outlets quantity
    • AP8861US power distribution unit (PDU) 44 AC outlet(s) 0U Black:44 AC outlet(s)
    • 30A/32A 24-Outlet Outlet-Metered & Switched eco PDU:24 AC outlet(s)
  • Power plug
    • AP8861US power distribution unit (PDU) 44 AC outlet(s) 0U Black:NEMA L21-20P
    • 30A/32A 24-Outlet Outlet-Metered & Switched eco PDU:IEC 60309
  • Cable length
    • AP8861US power distribution unit (PDU) 44 AC outlet(s) 0U Black:1.82 m
    • 30A/32A 24-Outlet Outlet-Metered & Switched eco PDU:1.6 m
  • Nominal input voltage
    • AP8861US power distribution unit (PDU) 44 AC outlet(s) 0U Black:120,208 V
    • 30A/32A 24-Outlet Outlet-Metered & Switched eco PDU:100 - 240 V
  • Maximum current
    • AP8861US power distribution unit (PDU) 44 AC outlet(s) 0U Black:20 A
    • 30A/32A 24-Outlet Outlet-Metered & Switched eco PDU:32 A
  • Load capacity
    • AP8861US power distribution unit (PDU) 44 AC outlet(s) 0U Black:5700 VA
    • 30A/32A 24-Outlet Outlet-Metered & Switched eco PDU:7360 VA
  • Operating temperature (T-T)
    • AP8861US power distribution unit (PDU) 44 AC outlet(s) 0U Black:0 - 55 °C
    • 30A/32A 24-Outlet Outlet-Metered & Switched eco PDU:0 - 40 °C

Side by side

Differences highlightedShow differences only (off)
Comparison of AP8861US, PE8324G3-AT
47 specifications
Design1 differ
PDU typesDiffersMeteredMetered, Switched
Product colourBlackBlack
On/off switchKnown for oneUnknown — not stated by the sourceYes
TypeKnown for oneThree-phaseUnknown — not stated by the source
Rack capacityKnown for one0UUnknown — not stated by the source
MountingKnown for oneVerticalUnknown — not stated by the source
Ports & interfaces3 differ
AC outlets quantityDiffers44 AC outlet(s)24 AC outlet(s)
Power plugDiffersNEMA L21-20PIEC 60309
AC outlet typesDiffersC13 coupler, C19 coupler, NEMA 5–20C13 coupler, C19 coupler
Ethernet LAN (RJ-45) portsKnown for oneUnknown — not stated by the source1
Features1 differ
Cable lengthDiffers1.82 m1.6 m
Security algorithmsKnown for oneUnknown — not stated by the source128-bit SSL, 802.1x RADIUS
Management featuresidentical
MonitoringKnown for oneUnknown — not stated by the sourceCurrent, Humidity, Power, Temperature, Voltage
Outlet controlKnown for oneUnknown — not stated by the sourceTurn off, Turn on
Supported network protocolsKnown for oneUnknown — not stated by the sourceTCP / IP, UDP, HTTP, HTTPS, SSL, DHCP, ARP, NTP, DNS, Telnet, Auto Sense, Ping, SNMP V1,V2, V3
Power3 differ
Nominal input voltageDiffers120,208 V100 - 240 V
AC input frequencyKnown for oneUnknown — not stated by the source50 - 60 Hz
Maximum currentDiffers20 A32 A
Block 1 output currentKnown for oneUnknown — not stated by the source15 A
Block 2 output currentKnown for oneUnknown — not stated by the source15 A
Output voltageKnown for oneUnknown — not stated by the source100 - 240 V
Load capacityDiffers5700 VA7360 VA
Maximum total current draw per phaseKnown for oneUnknown — not stated by the source32 A
Certificatesidentical
Compliance certificatesKnown for oneUnknown — not stated by the sourceCE
Operational conditions3 differ
Operating temperature (T-T)Differs0 - 55 °C0 - 40 °C
Storage temperature (T-T)Differs-25 - 65 °C-20 - 60 °C
Operating relative humidity (H-H)Differs5 - 95%0 - 80%
Operating altitudeKnown for one0 - 3000 mUnknown — not stated by the source
Non-operating altitudeKnown for one0 - 15240 mUnknown — not stated by the source
Weight & dimensions4 differ
WidthDiffers56 mm66 mm
DepthDiffers44 mm177.5 mm
HeightDiffers1791 mm44 mm
WeightDiffers6.34 kg6.33 kg
Packaging contentidentical
ManualKnown for oneUnknown — not stated by the sourceYes
Rack mount kitKnown for oneUnknown — not stated by the sourceYes
Packaging data4 differ
Package weightDiffers7.97 kg9.38 kg
Package widthDiffers107 mm229 mm
Package depthDiffers162 mm1865 mm
Package heightDiffers2000 mm179 mm
Package volumeKnown for oneUnknown — not stated by the source76455.49 cm³
Logistics dataidentical
Country of originKnown for oneUnknown — not stated by the sourceTaiwan
Master (outer) case net weightKnown for oneUnknown — not stated by the source6.72 kg
Master (outer) case widthKnown for oneUnknown — not stated by the source229 mm
Master (outer) case lengthKnown for oneUnknown — not stated by the source1865 mm
Master (outer) case heightKnown for oneUnknown — not stated by the source179 mm
Master (outer) case gross weightKnown for oneUnknown — not stated by the source9.37 kg
Master (outer) case volumeKnown for oneUnknown — not stated by the source76455.49 cm³

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.