Product comparison · 2 power distribution units (pdus)

APC AP8861US power distribution unit (PDU) 44 AC outlet(s) 0U Black vs APC NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets

Add a product
  • 23specifications compared
  • 16differ
  • 7identical
  • 7known for one product only

Key differences

The APC AP8861US power distribution unit (PDU) 44 AC outlet(s) 0U Black has 120,000 V more nominal input voltage than the APC NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets (120,208 V vs 208 V). The APC NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets has 80 A more maximum current than the APC AP8861US power distribution unit (PDU) 44 AC outlet(s) 0U Black (100 A vs 20 A). The APC NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets has 23,100 VA more load capacity than the APC AP8861US power distribution unit (PDU) 44 AC outlet(s) 0U Black (28800 VA vs 5700 VA). AC outlets quantity: 44 AC outlet(s) on the APC AP8861US power distribution unit (PDU) 44 AC outlet(s) 0U Black, 30 AC outlet(s) on the APC NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets. Power plug: NEMA L21-20P on the APC AP8861US power distribution unit (PDU) 44 AC outlet(s) 0U Black, IEC 60309 on the APC NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets.

  • AC outlets quantity
    • AP8861US power distribution unit (PDU) 44 AC outlet(s) 0U Black:44 AC outlet(s)
    • NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets:30 AC outlet(s)
  • Power plug
    • AP8861US power distribution unit (PDU) 44 AC outlet(s) 0U Black:NEMA L21-20P
    • NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets:IEC 60309
  • Nominal input voltage
    • AP8861US power distribution unit (PDU) 44 AC outlet(s) 0U Black:120,208 V
    • NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets:208 V
  • Maximum current
    • AP8861US power distribution unit (PDU) 44 AC outlet(s) 0U Black:20 A
    • NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets:100 A
  • Load capacity
    • AP8861US power distribution unit (PDU) 44 AC outlet(s) 0U Black:5700 VA
    • NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets:28800 VA
  • Operating temperature (T-T)
    • AP8861US power distribution unit (PDU) 44 AC outlet(s) 0U Black:0 - 55 °C
    • NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets:-5 - 60 °C
  • Storage temperature (T-T)
    • AP8861US power distribution unit (PDU) 44 AC outlet(s) 0U Black:-25 - 65 °C
    • NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets:-20 - 60 °C
  • Operating relative humidity (H-H)
    • AP8861US power distribution unit (PDU) 44 AC outlet(s) 0U Black:5 - 95%
    • NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets:5 - 90%

Side by side

Differences highlightedShow differences only (off)
Comparison of AP8861US, NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets
30 specifications
Designidentical
PDU typesMeteredMetered
TypeThree-phaseThree-phase
Rack capacity0U0U
MountingVerticalVertical
Product colourBlackBlack
Ports & interfaces3 differ
AC outlets quantityDiffers44 AC outlet(s)30 AC outlet(s)
Power plugDiffersNEMA L21-20PIEC 60309
AC outlet typesDiffersC13 coupler, C19 coupler, NEMA 5–20C15 coupler, C13 coupler, C19 coupler, C21 coupler
Featuresidentical
International Protection (IP) codeKnown for oneUnknown — not stated by the sourceIP67
Cable lengthKnown for one1.82 mUnknown — not stated by the source
Management featuresidentical
Management platformKnown for oneUnknown — not stated by the sourceNMC3
Power3 differ
Nominal input voltageDiffers120,208 V208 V
AC input frequencyKnown for oneUnknown — not stated by the source50/60 Hz
Maximum currentDiffers20 A100 A
Output voltageKnown for oneUnknown — not stated by the source208 V
Load capacityDiffers5700 VA28800 VA
Operational conditions3 differ
Operating temperature (T-T)Differs0 - 55 °C-5 - 60 °C
Storage temperature (T-T)Differs-25 - 65 °C-20 - 60 °C
Operating relative humidity (H-H)Differs5 - 95%5 - 90%
Storage relative humidity (H-H)Known for oneUnknown — not stated by the source5 - 95%
Non-operating altitude0 - 15240 m0 - 15240 m
Operating altitudeKnown for one0 - 3000 mUnknown — not stated by the source
Weight & dimensions3 differ
Width56 mm56 mm
DepthDiffers44 mm75 mm
HeightDiffers1791 mm1900 mm
WeightDiffers6.34 kg14 kg
Packaging data4 differ
Package weightDiffers7.97 kg19.8 kg
Package widthDiffers107 mm350 mm
Package depthDiffers162 mm165 mm
Package heightDiffers2000 mm2110 mm