Product comparison · 2 power distribution units (pdus)

APC AP8858NA3 power distribution unit (PDU) Black vs Vertiv Knürr DIS Rack PDU, TripplePower, 0U, input IEC 60309 230/400V

Add a product
  • 7specifications compared
  • 7differ
  • 0identical
  • 24known for one product only

Key differences

  • Product colour
    • AP8858NA3 power distribution unit (PDU) Black:Black
    • Knürr DIS Rack PDU, TripplePower, 0U, input IEC 60309 230/400V:Grey
  • Input connection type
    • AP8858NA3 power distribution unit (PDU) Black:NEMA L6-20P
    • Knürr DIS Rack PDU, TripplePower, 0U, input IEC 60309 230/400V:IEC60309 3ph/N/PE 6h
  • Cable length
    • AP8858NA3 power distribution unit (PDU) Black:3 m
    • Knürr DIS Rack PDU, TripplePower, 0U, input IEC 60309 230/400V:2.5 m
  • Width
    • AP8858NA3 power distribution unit (PDU) Black:56 mm
    • Knürr DIS Rack PDU, TripplePower, 0U, input IEC 60309 230/400V:44.4 mm
  • Depth
    • AP8858NA3 power distribution unit (PDU) Black:44 mm
    • Knürr DIS Rack PDU, TripplePower, 0U, input IEC 60309 230/400V:1833 mm
  • Height
    • AP8858NA3 power distribution unit (PDU) Black:902 mm
    • Knürr DIS Rack PDU, TripplePower, 0U, input IEC 60309 230/400V:45.5 mm

Side by side

Differences highlightedShow differences only (off)
Comparison of AP8858NA3, 03.600.848.1
31 specifications
Design1 differ
Product colourDiffersBlackGrey
Rack capacityKnown for oneUnknown — not stated by the source0U
Housing materialKnown for oneUnknown — not stated by the sourcePlastic, Steel, Zinc
Ports & interfaces1 differ
Input connection typeDiffersNEMA L6-20PIEC60309 3ph/N/PE 6h
Output connectionsKnown for one18x IEC 320 C13 2x IEC 320 C19Unknown — not stated by the source
AC outlets quantityKnown for oneUnknown — not stated by the source48 AC outlet(s)
Power plugKnown for oneUnknown — not stated by the sourceIEC 60309
AC outlet typesKnown for oneUnknown — not stated by the sourceC13 coupler
Features1 differ
Cable lengthDiffers3 m2.5 m
Cable typeKnown for oneUnknown — not stated by the sourceH05VV-F 5 G 2.5 mm2
Poweridentical
AC input frequencyKnown for one50 - 60 HzUnknown — not stated by the source
Nominal output voltageKnown for one208 VUnknown — not stated by the source
Maximum input current per phaseKnown for one20 AUnknown — not stated by the source
Maximum total current draw per phaseKnown for one20 AUnknown — not stated by the source
Nominal input voltageKnown for oneUnknown — not stated by the source230-400 V
Maximum currentKnown for oneUnknown — not stated by the source16 A
Certificates1 differ
CertificationDiffersCSA C22.2 No. 60950,IEC 60950,METI Denan,UL 60950-1,VDE- CE label in accordance with Low Voltage Directive 2006/95/EC. - EMC Directive 2004/108/EC. - BV BG. - CB scheme. - IEC 320.
Operational conditionsidentical
Operating temperature (T-T)Known for one5 - 45 °CUnknown — not stated by the source
Storage temperature (T-T)Known for one-25 - 65 °CUnknown — not stated by the source
Operating relative humidity (H-H)Known for one5 - 95%Unknown — not stated by the source
Storage relative humidity (H-H)Known for one5 - 95%Unknown — not stated by the source
Weight & dimensions3 differ
WidthDiffers56 mm44.4 mm
DepthDiffers44 mm1833 mm
HeightDiffers902 mm45.5 mm
WeightKnown for one2.93 kgUnknown — not stated by the source
Packaging dataidentical
Package weightKnown for one4.92 kgUnknown — not stated by the source
Package widthKnown for one162 mmUnknown — not stated by the source
Package depthKnown for one107 mmUnknown — not stated by the source
Package heightKnown for one1124 mmUnknown — not stated by the source
Logistics dataidentical
Total carbon footprint (kg of CO2e)Known for one13903.66Unknown — not stated by the source
Packaging contentidentical
Packaging contentKnown for oneUnknown — not stated by the source- 1 x socket strip. - 2 x mounting brackets.

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.