Product comparison · 2 power distribution units (pdus)

APC AP8858 power distribution unit (PDU) 20 AC outlet(s) 0U Black vs APC AP8858EU3 power distribution unit (PDU) 20 AC outlet(s) 0U

Add a product
  • 27specifications compared
  • 3differ
  • 24identical
  • 5known for one product only

Key differences

  • Input connection type
    • AP8858 power distribution unit (PDU) 20 AC outlet(s) 0U Black:IEC-320 C20
    • AP8858EU3 power distribution unit (PDU) 20 AC outlet(s) 0U:IEC 309 16A 2P+E
  • Package weight
    • AP8858 power distribution unit (PDU) 20 AC outlet(s) 0U Black:4.2 kg
    • AP8858EU3 power distribution unit (PDU) 20 AC outlet(s) 0U:4.92 kg
  • Total carbon footprint (kg of CO2e)
    • AP8858 power distribution unit (PDU) 20 AC outlet(s) 0U Black:12787.89
    • AP8858EU3 power distribution unit (PDU) 20 AC outlet(s) 0U:13349.44

Side by side

Differences highlightedShow differences only (off)
Comparison of AP8858, AP8858EU3
32 specifications
Designidentical
PDU typesMeteredMetered
Rack capacity0U0U
MountingVerticalVertical
Product colourKnown for oneBlackUnknown — not stated by the source
Ports & interfaces1 differ
AC outlets quantity20 AC outlet(s)20 AC outlet(s)
Power plugKnown for oneUnknown — not stated by the sourceIEC309
AC outlet typesC13 coupler, C19 couplerC13 coupler, C19 coupler
Input connection typeDiffersIEC-320 C20IEC 309 16A 2P+E
Output connections18x IEC 320 C13 2x IEC 320 C1918x IEC 320 C13 2x IEC 320 C19
Featuresidentical
Cable lengthKnown for oneUnknown — not stated by the source3 m
Management featuresidentical
MonitoringCurrent, Power, VoltageCurrent, Power, Voltage
Poweridentical
AC input frequency50 - 60 Hz50 - 60 Hz
Nominal output voltageKnown for oneUnknown — not stated by the source230 V
Load capacity3680 VA3680 VA
Maximum input current per phase16 A16 A
Maximum total current draw per phase16 A16 A
Maximum power3680 W3680 W
Nominal input voltageKnown for one230 VUnknown — not stated by the source
Certificatesidentical
CertificationCSA C22.2 No. 60950,IEC 60950,METI Denan,UL 60950-1,VDE RoHS, REACHCSA C22.2 No. 60950,IEC 60950,METI Denan,UL 60950-1,VDE RoHS, REACH
Operational conditionsidentical
Operating temperature (T-T)5 - 45 °C5 - 45 °C
Storage temperature (T-T)-25 - 65 °C-25 - 65 °C
Operating relative humidity (H-H)5 - 95%5 - 95%
Storage relative humidity (H-H)5 - 95%5 - 95%
Weight & dimensionsidentical
Width56 mm56 mm
Depth44 mm44 mm
Height902 mm902 mm
Weight2.93 kg2.93 kg
Packaging data1 differ
Package weightDiffers4.2 kg4.92 kg
Package width162 mm162 mm
Package depth107 mm107 mm
Package height1124 mm1124 mm
Logistics data1 differ
Total carbon footprint (kg of CO2e)Differs12787.8913349.44

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.