The Vertiv PowerIT VP4G31A2 power distribution unit (PDU) 36 AC outlet(s) 0U Black has 0.1 m more cable length than the APC NetShelter Rack PDU, Metered, 0U, 5.0kW (3 m vs 2.9 m). The Vertiv PowerIT VP4G31A2 power distribution unit (PDU) 36 AC outlet(s) 0U Black has 2 A more maximum current than the APC NetShelter Rack PDU, Metered, 0U, 5.0kW (32 A vs 30 A). The APC NetShelter Rack PDU, Metered, 0U, 5.0kW has 4,762 VA more load capacity than the Vertiv PowerIT VP4G31A2 power distribution unit (PDU) 36 AC outlet(s) 0U Black (4992 VA vs 230 VA). PDU types: Basic on the APC NetShelter Rack PDU, Metered, 0U, 5.0kW, Switched on the Vertiv PowerIT VP4G31A2 power distribution unit (PDU) 36 AC outlet(s) 0U Black. Type: Single-phase on the APC NetShelter Rack PDU, Metered, 0U, 5.0kW, Three-phase on the Vertiv PowerIT VP4G31A2 power distribution unit (PDU) 36 AC outlet(s) 0U Black.

  • PDU types
    • NetShelter Rack PDU, Metered, 0U, 5.0kW:Basic
    • PowerIT VP4G31A2 power distribution unit (PDU) 36 AC outlet(s) 0U Black:Switched
  • Type
    • NetShelter Rack PDU, Metered, 0U, 5.0kW:Single-phase
    • PowerIT VP4G31A2 power distribution unit (PDU) 36 AC outlet(s) 0U Black:Three-phase
  • AC outlets quantity
    • NetShelter Rack PDU, Metered, 0U, 5.0kW:42 AC outlet(s)
    • PowerIT VP4G31A2 power distribution unit (PDU) 36 AC outlet(s) 0U Black:36 AC outlet(s)
  • Power plug
    • NetShelter Rack PDU, Metered, 0U, 5.0kW:NEMA L6-30P
    • PowerIT VP4G31A2 power distribution unit (PDU) 36 AC outlet(s) 0U Black:IEC 60309
  • AC outlet types
    • NetShelter Rack PDU, Metered, 0U, 5.0kW:NEMA L6-30P
    • PowerIT VP4G31A2 power distribution unit (PDU) 36 AC outlet(s) 0U Black:C13 coupler, C19 coupler
  • Cable length
    • NetShelter Rack PDU, Metered, 0U, 5.0kW:2.9 m
    • PowerIT VP4G31A2 power distribution unit (PDU) 36 AC outlet(s) 0U Black:3 m
  • Nominal input voltage
    • NetShelter Rack PDU, Metered, 0U, 5.0kW:200; 208 V
    • PowerIT VP4G31A2 power distribution unit (PDU) 36 AC outlet(s) 0U Black:200-240/346-415 V
  • AC input frequency
    • NetShelter Rack PDU, Metered, 0U, 5.0kW:50-60 Hz
    • PowerIT VP4G31A2 power distribution unit (PDU) 36 AC outlet(s) 0U Black:50/60 Hz

Side by side

Differences highlightedShow differences only (off)
Comparison of AP8841, VP4G31A2
56 specifications
Design2 differ
PDU typesDiffersBasicSwitched
TypeDiffersSingle-phaseThree-phase
Rack capacity0U0U
MountingVerticalVertical
Product colourBlackBlack
DisplayKnown for oneUnknown — not stated by the sourceLCD
Ports & interfaces3 differ
AC outlets quantityDiffers42 AC outlet(s)36 AC outlet(s)
Power plugDiffersNEMA L6-30PIEC 60309
AC outlet typesDiffersNEMA L6-30PC13 coupler, C19 coupler
Input connection typeKnown for oneNEMA L6-30PUnknown — not stated by the source
Output connectionsKnown for one36x IEC 320 C13 6x IEC 320 C19Unknown — not stated by the source
Serial ports quantityKnown for oneUnknown — not stated by the source1
Ethernet LAN (RJ-45) portsKnown for oneUnknown — not stated by the source1
USB ports quantityKnown for oneUnknown — not stated by the source1
Features1 differ
Cable lengthDiffers2.9 m3 m
Reset buttonKnown for oneUnknown — not stated by the sourceYes
Power4 differ
Nominal input voltageDiffers200; 208 V200-240/346-415 V
AC input frequencyDiffers50-60 Hz50/60 Hz
Maximum currentDiffers30 A32 A
Output voltageKnown for one200 V; 208 VUnknown — not stated by the source
Load capacityDiffers4992 VA230 VA
Maximum input current per phaseKnown for one30 AUnknown — not stated by the source
Maximum total current draw per phaseKnown for one30 AUnknown — not stated by the source
Power protection featuresKnown for oneUnknown — not stated by the sourceOver current
Certificates1 differ
Compliance certificatesDiffersRoHS, REACH, WEEERoHS, UKCA, CE
Waste Electrical and Electronic Equipment (WEEE) complianceKnown for oneYesUnknown — not stated by the source
CertificationKnown for oneCSA C22.2 No. 60950,IEC 60950,METI Denan,UL 60950-1,VDE RoHS,REACHUnknown — not stated by the source
Operational conditions1 differ
Operating temperature (T-T)Differs-5 - 60 °C0 - 60 °C
Storage temperature (T-T)Known for one-25 - 65 °CUnknown — not stated by the source
Operating relative humidity (H-H)Known for one5 - 95%Unknown — not stated by the source
Storage relative humidity (H-H)Known for one5 - 95%Unknown — not stated by the source
Operating altitudeKnown for one0 - 3000 mUnknown — not stated by the source
Non-operating altitudeKnown for one0 - 15240 mUnknown — not stated by the source
Weight & dimensions3 differ
WidthDiffers56 mm51 mm
DepthDiffers44 mm66 mm
HeightDiffers1791 mm1829 mm
WeightKnown for one6.84 kgUnknown — not stated by the source
Packaging contentidentical
Cables includedKnown for oneSerialUnknown — not stated by the source
ManualKnown for oneYesUnknown — not stated by the source
Packaging data1 differ
Package weightDiffers6.47 kg9.98 kg
Package widthKnown for one107 mmUnknown — not stated by the source
Package depthKnown for one162 mmUnknown — not stated by the source
Package heightKnown for one2000 mmUnknown — not stated by the source
Technical detailsidentical
Halogen freeKnown for oneNoUnknown — not stated by the source
Packaging recycled materialsKnown for oneRecycled cardboardUnknown — not stated by the source
Preferred mounting positionKnown for oneno preferenceUnknown — not stated by the source
Removable batteryKnown for oneYesUnknown — not stated by the source
Packaging without single use plasticKnown for oneNoUnknown — not stated by the source
Sustainable packagingKnown for oneNoUnknown — not stated by the source
Take-back systemKnown for oneNoUnknown — not stated by the source
Logistics dataidentical
Country of originKnown for oneIndiaUnknown — not stated by the source
Customs product code (TARIC)Known for one8537109899Unknown — not stated by the source
Total carbon footprint (kg of CO2e)Known for one2676.8173692539Unknown — not stated by the source
Warranty periodKnown for oneUnknown — not stated by the source5 year(s)
Management featuresidentical
MonitoringKnown for oneUnknown — not stated by the sourceCurrent, Power, Voltage
Supported network protocolsKnown for oneUnknown — not stated by the sourceDHCP, HTTP, HTTPS, IPv4, IPv6, LDAP, NTP, RADIUS, RSTP, SSH, SMTP, SNMP (v1/v2c/v3), Syslog, TACACS+, Modbus TCP