Product comparison · 2 power distribution units (pdus)

APC NetShelter Rack PDU, Metered, 0U, 5.0kW vs Vertiv VP0G9000 power distribution unit (PDU) 24 AC outlet(s) Black

Add a product
  • 16specifications compared
  • 13differ
  • 3identical
  • 33known for one product only

Key differences

The Vertiv VP0G9000 power distribution unit (PDU) 24 AC outlet(s) Black has 0.1 m more cable length than the APC NetShelter Rack PDU, Metered, 0U, 5.0kW (3 m vs 2.9 m). The Vertiv VP0G9000 power distribution unit (PDU) 24 AC outlet(s) Black has 2 A more maximum current than the APC NetShelter Rack PDU, Metered, 0U, 5.0kW (32 A vs 30 A). The Vertiv VP0G9000 power distribution unit (PDU) 24 AC outlet(s) Black has 454 mm more width than the APC NetShelter Rack PDU, Metered, 0U, 5.0kW (510 mm vs 56 mm). AC outlets quantity: 42 AC outlet(s) on the APC NetShelter Rack PDU, Metered, 0U, 5.0kW, 24 AC outlet(s) on the Vertiv VP0G9000 power distribution unit (PDU) 24 AC outlet(s) Black. Power plug: NEMA L6-30P on the APC NetShelter Rack PDU, Metered, 0U, 5.0kW, IEC 60309 on the Vertiv VP0G9000 power distribution unit (PDU) 24 AC outlet(s) Black.

  • AC outlets quantity
    • NetShelter Rack PDU, Metered, 0U, 5.0kW:42 AC outlet(s)
    • VP0G9000 power distribution unit (PDU) 24 AC outlet(s) Black:24 AC outlet(s)
  • Power plug
    • NetShelter Rack PDU, Metered, 0U, 5.0kW:NEMA L6-30P
    • VP0G9000 power distribution unit (PDU) 24 AC outlet(s) Black:IEC 60309
  • AC outlet types
    • NetShelter Rack PDU, Metered, 0U, 5.0kW:NEMA L6-30P
    • VP0G9000 power distribution unit (PDU) 24 AC outlet(s) Black:C13 coupler, C19 coupler
  • Cable length
    • NetShelter Rack PDU, Metered, 0U, 5.0kW:2.9 m
    • VP0G9000 power distribution unit (PDU) 24 AC outlet(s) Black:3 m
  • Nominal input voltage
    • NetShelter Rack PDU, Metered, 0U, 5.0kW:200; 208 V
    • VP0G9000 power distribution unit (PDU) 24 AC outlet(s) Black:220 - 240 V
  • AC input frequency
    • NetShelter Rack PDU, Metered, 0U, 5.0kW:50-60 Hz
    • VP0G9000 power distribution unit (PDU) 24 AC outlet(s) Black:50 - 60 Hz
  • Maximum current
    • NetShelter Rack PDU, Metered, 0U, 5.0kW:30 A
    • VP0G9000 power distribution unit (PDU) 24 AC outlet(s) Black:32 A
  • Output voltage
    • NetShelter Rack PDU, Metered, 0U, 5.0kW:200 V; 208 V
    • VP0G9000 power distribution unit (PDU) 24 AC outlet(s) Black:230 V

Side by side

Differences highlightedShow differences only (off)
Comparison of AP8841, VP0G9000
49 specifications
Designidentical
PDU typesBasicBasic
TypeKnown for oneSingle-phaseUnknown — not stated by the source
Rack capacityKnown for one0UUnknown — not stated by the source
MountingVerticalVertical
Product colourBlackBlack
Ports & interfaces3 differ
AC outlets quantityDiffers42 AC outlet(s)24 AC outlet(s)
Power plugDiffersNEMA L6-30PIEC 60309
AC outlet typesDiffersNEMA L6-30PC13 coupler, C19 coupler
Input connection typeKnown for oneNEMA L6-30PUnknown — not stated by the source
Output connectionsKnown for one36x IEC 320 C13 6x IEC 320 C19Unknown — not stated by the source
Features1 differ
Cable lengthDiffers2.9 m3 m
Power4 differ
Nominal input voltageDiffers200; 208 V220 - 240 V
AC input frequencyDiffers50-60 Hz50 - 60 Hz
Maximum currentDiffers30 A32 A
Output voltageDiffers200 V; 208 V230 V
Load capacityKnown for one4992 VAUnknown — not stated by the source
Maximum input current per phaseKnown for one30 AUnknown — not stated by the source
Maximum total current draw per phaseKnown for one30 AUnknown — not stated by the source
Maximum powerKnown for oneUnknown — not stated by the source7300 W
Certificates1 differ
Compliance certificatesDiffersRoHS, REACH, WEEERoHS
Waste Electrical and Electronic Equipment (WEEE) complianceKnown for oneYesUnknown — not stated by the source
CertificationKnown for oneCSA C22.2 No. 60950,IEC 60950,METI Denan,UL 60950-1,VDE RoHS,REACHUnknown — not stated by the source
Operational conditionsidentical
Operating temperature (T-T)Known for one-5 - 60 °CUnknown — not stated by the source
Storage temperature (T-T)Known for one-25 - 65 °CUnknown — not stated by the source
Operating relative humidity (H-H)Known for one5 - 95%Unknown — not stated by the source
Storage relative humidity (H-H)Known for one5 - 95%Unknown — not stated by the source
Operating altitudeKnown for one0 - 3000 mUnknown — not stated by the source
Non-operating altitudeKnown for one0 - 15240 mUnknown — not stated by the source
Weight & dimensions4 differ
WidthDiffers56 mm510 mm
DepthDiffers44 mm510 mm
HeightDiffers1791 mm1683 mm
WeightDiffers6.84 kg6.35 kg
Packaging contentidentical
Cables includedKnown for oneSerialUnknown — not stated by the source
ManualKnown for oneYesUnknown — not stated by the source
Packaging dataidentical
Package weightKnown for one6.47 kgUnknown — not stated by the source
Package widthKnown for one107 mmUnknown — not stated by the source
Package depthKnown for one162 mmUnknown — not stated by the source
Package heightKnown for one2000 mmUnknown — not stated by the source
Technical detailsidentical
Halogen freeKnown for oneNoUnknown — not stated by the source
Packaging recycled materialsKnown for oneRecycled cardboardUnknown — not stated by the source
Preferred mounting positionKnown for oneno preferenceUnknown — not stated by the source
Removable batteryKnown for oneYesUnknown — not stated by the source
Packaging without single use plasticKnown for oneNoUnknown — not stated by the source
Sustainable packagingKnown for oneNoUnknown — not stated by the source
Take-back systemKnown for oneNoUnknown — not stated by the source
Logistics dataidentical
Country of originKnown for oneIndiaUnknown — not stated by the source
Customs product code (TARIC)Known for one8537109899Unknown — not stated by the source
Total carbon footprint (kg of CO2e)Known for one2676.8173692539Unknown — not stated by the source
Management featuresidentical
MonitoringKnown for oneUnknown — not stated by the sourceCurrent, Power, Voltage

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.