Product comparison · 2 power distribution units (pdus)

APC NetShelter Rack PDU, Metered, 0U, 5.0kW vs APC NetShelter Rack PDU Advanced Switched Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 48 Outlets

Add a product
  • 34specifications compared
  • 23differ
  • 11identical
  • 18known for one product only

Key differences

The APC NetShelter Rack PDU Advanced Switched Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 48 Outlets has 70 A more maximum current than the APC NetShelter Rack PDU, Metered, 0U, 5.0kW (100 A vs 30 A). The APC NetShelter Rack PDU Advanced Switched Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 48 Outlets has 64,008 VA more load capacity than the APC NetShelter Rack PDU, Metered, 0U, 5.0kW (69000 VA vs 4992 VA). The APC NetShelter Rack PDU Advanced Switched Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 48 Outlets has 29 mm more width than the APC NetShelter Rack PDU, Metered, 0U, 5.0kW (85 mm vs 56 mm). Only the APC NetShelter Rack PDU Advanced Switched Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 48 Outlets has packaging without single use plastic. PDU types: Basic on the APC NetShelter Rack PDU, Metered, 0U, 5.0kW, Metered-by-outlet, Switched on the APC NetShelter Rack PDU Advanced Switched Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 48 Outlets.

  • PDU types
    • NetShelter Rack PDU, Metered, 0U, 5.0kW:Basic
    • NetShelter Rack PDU Advanced Switched Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 48 Outlets:Metered-by-outlet, Switched
  • Type
    • NetShelter Rack PDU, Metered, 0U, 5.0kW:Single-phase
    • NetShelter Rack PDU Advanced Switched Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 48 Outlets:Three-phase
  • AC outlets quantity
    • NetShelter Rack PDU, Metered, 0U, 5.0kW:42 AC outlet(s)
    • NetShelter Rack PDU Advanced Switched Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 48 Outlets:48 AC outlet(s)
  • Power plug
    • NetShelter Rack PDU, Metered, 0U, 5.0kW:NEMA L6-30P
    • NetShelter Rack PDU Advanced Switched Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 48 Outlets:IEC 60309
  • Input connection type
    • NetShelter Rack PDU, Metered, 0U, 5.0kW:NEMA L6-30P
    • NetShelter Rack PDU Advanced Switched Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 48 Outlets:IEC 309 100 A
  • Nominal input voltage
    • NetShelter Rack PDU, Metered, 0U, 5.0kW:200; 208 V
    • NetShelter Rack PDU Advanced Switched Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 48 Outlets:415 3 phases
  • AC input frequency
    • NetShelter Rack PDU, Metered, 0U, 5.0kW:50-60 Hz
    • NetShelter Rack PDU Advanced Switched Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 48 Outlets:50/60 Hz
  • Maximum current
    • NetShelter Rack PDU, Metered, 0U, 5.0kW:30 A
    • NetShelter Rack PDU Advanced Switched Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 48 Outlets:100 A

Side by side

Differences highlightedShow differences only (on)
Comparison of AP8841, NetShelter Rack PDU Advanced Switched Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 48 Outlets
52 specifications
Design2 differ
PDU typesDiffersBasicMetered-by-outlet, Switched
TypeDiffersSingle-phaseThree-phase
UpgradeableKnown for oneUnknown — not stated by the sourceYes
Ports & interfaces4 differ
AC outlets quantityDiffers42 AC outlet(s)48 AC outlet(s)
Power plugDiffersNEMA L6-30PIEC 60309
AC outlet typesDiffersNEMA L6-30PC13 coupler, C15 coupler, C19 coupler, C21 coupler
Input connection typeDiffersNEMA L6-30PIEC 309 100 A
Output connectionsKnown for one36x IEC 320 C13 6x IEC 320 C19Unknown — not stated by the source
Featuresidentical
Cable lengthKnown for one2.9 mUnknown — not stated by the source
International Protection (IP) codeKnown for oneUnknown — not stated by the sourceIP67
Power5 differ
Nominal input voltageDiffers200; 208 V415 3 phases
AC input frequencyDiffers50-60 Hz50/60 Hz
Maximum currentDiffers30 A100 A
Output voltageDiffers200 V; 208 V415 V AC 3 phases
Load capacityDiffers4992 VA69000 VA
Maximum input current per phaseKnown for one30 AUnknown — not stated by the source
Maximum total current draw per phaseKnown for one30 AUnknown — not stated by the source
Number of phasesKnown for oneUnknown — not stated by the source3
Certificates1 differ
Compliance certificatesDiffersRoHS, REACH, WEEERoHS, REACH
Waste Electrical and Electronic Equipment (WEEE) complianceKnown for oneYesUnknown — not stated by the source
CertificationKnown for oneCSA C22.2 No. 60950,IEC 60950,METI Denan,UL 60950-1,VDE RoHS,REACHUnknown — not stated by the source
Operational conditions2 differ
Storage temperature (T-T)Differs-25 - 65 °C-20 - 60 °C
Operating relative humidity (H-H)Differs5 - 95%5 - 90%
Operating altitudeKnown for one0 - 3000 mUnknown — not stated by the source
Weight & dimensions4 differ
WidthDiffers56 mm85 mm
DepthDiffers44 mm85 mm
HeightDiffers1791 mm2030 mm
WeightDiffers6.84 kg22.8 kg
Packaging contentidentical
Cables includedKnown for oneSerialUnknown — not stated by the source
ManualKnown for oneYesUnknown — not stated by the source
Packaging data4 differ
Package weightDiffers6.47 kg28.6 kg
Package widthDiffers107 mm350 mm
Package depthDiffers162 mm165 mm
Package heightDiffers2000 mm2320 mm
Technical details1 differ
Halogen freeKnown for oneNoUnknown — not stated by the source
Removable batteryKnown for oneYesUnknown — not stated by the source
Packaging without single use plasticDiffersNoYes
SCIP numberKnown for oneUnknown — not stated by the source31346aed-552c-4a16-81d9-e683a383b6da
Logistics dataidentical
Country of originKnown for oneIndiaUnknown — not stated by the source
Total carbon footprint (kg of CO2e)Known for one2676.8173692539Unknown — not stated by the source
Sustainabilityidentical
Doesn't containKnown for oneUnknown — not stated by the sourceSilicone

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.

More power distribution units (pdus) comparisons

All power distribution units (pdus) comparisons