Product comparison · 2 power distribution units (pdus)

APC NetShelter Rack PDU, Metered, 0U, 5.0kW vs APC NetShelter Rack PDU Advanced Gen 2, Switched, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlet

Add a product
  • 31specifications compared
  • 20differ
  • 11identical
  • 23known for one product only

Key differences

The APC NetShelter Rack PDU Advanced Gen 2, Switched, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlet has 0.1 m more cable length than the APC NetShelter Rack PDU, Metered, 0U, 5.0kW (3 m vs 2.9 m). The APC NetShelter Rack PDU Advanced Gen 2, Switched, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlet has 30 A more maximum current than the APC NetShelter Rack PDU, Metered, 0U, 5.0kW (60 A vs 30 A). The APC NetShelter Rack PDU Advanced Gen 2, Switched, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlet has 29,608 VA more load capacity than the APC NetShelter Rack PDU, Metered, 0U, 5.0kW (34600 VA vs 4992 VA). Only the APC NetShelter Rack PDU, Metered, 0U, 5.0kW has removable battery. PDU types: Basic on the APC NetShelter Rack PDU, Metered, 0U, 5.0kW, Metered on the APC NetShelter Rack PDU Advanced Gen 2, Switched, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlet.

  • PDU types
    • NetShelter Rack PDU, Metered, 0U, 5.0kW:Basic
    • NetShelter Rack PDU Advanced Gen 2, Switched, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlet:Metered
  • Type
    • NetShelter Rack PDU, Metered, 0U, 5.0kW:Single-phase
    • NetShelter Rack PDU Advanced Gen 2, Switched, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlet:Three-phase
  • Input connection type
    • NetShelter Rack PDU, Metered, 0U, 5.0kW:NEMA L6-30P
    • NetShelter Rack PDU Advanced Gen 2, Switched, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlet:IEC 60309 32 A 2P + PE
  • Cable length
    • NetShelter Rack PDU, Metered, 0U, 5.0kW:2.9 m
    • NetShelter Rack PDU Advanced Gen 2, Switched, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlet:3 m
  • Nominal input voltage
    • NetShelter Rack PDU, Metered, 0U, 5.0kW:200; 208 V
    • NetShelter Rack PDU Advanced Gen 2, Switched, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlet:230 1 phase
  • AC input frequency
    • NetShelter Rack PDU, Metered, 0U, 5.0kW:50-60 Hz
    • NetShelter Rack PDU Advanced Gen 2, Switched, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlet:50/60 Hz
  • Maximum current
    • NetShelter Rack PDU, Metered, 0U, 5.0kW:30 A
    • NetShelter Rack PDU Advanced Gen 2, Switched, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlet:60 A
  • Output voltage
    • NetShelter Rack PDU, Metered, 0U, 5.0kW:200 V; 208 V
    • NetShelter Rack PDU Advanced Gen 2, Switched, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlet:230 V

Side by side

Differences highlightedShow differences only (on)
Comparison of AP8841, NetShelter Rack PDU Advanced Gen 2, Switched, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlet
54 specifications
Design2 differ
PDU typesDiffersBasicMetered
TypeDiffersSingle-phaseThree-phase
MountingKnown for oneVerticalUnknown — not stated by the source
Ports & interfaces2 differ
Power plugKnown for oneNEMA L6-30PUnknown — not stated by the source
AC outlet typesDiffersNEMA L6-30PC13 coupler, C15 coupler, C19 coupler, C21 coupler
Input connection typeDiffersNEMA L6-30PIEC 60309 32 A 2P + PE
Output connectionsKnown for one36x IEC 320 C13 6x IEC 320 C19Unknown — not stated by the source
Ethernet LAN (RJ-45) portsKnown for oneUnknown — not stated by the source5
USB ports quantityKnown for oneUnknown — not stated by the source1
Features1 differ
Cable lengthDiffers2.9 m3 m
Power5 differ
Nominal input voltageDiffers200; 208 V230 1 phase
AC input frequencyDiffers50-60 Hz50/60 Hz
Maximum currentDiffers30 A60 A
Output voltageDiffers200 V; 208 V230 V
Load capacityDiffers4992 VA34600 VA
Maximum input current per phaseKnown for one30 AUnknown — not stated by the source
Maximum total current draw per phaseKnown for one30 AUnknown — not stated by the source
Nominal output voltageKnown for oneUnknown — not stated by the source400 V
Number of phasesKnown for oneUnknown — not stated by the source1
Battery replacement accessibilityKnown for oneUnknown — not stated by the sourceNon-removable
Certificates1 differ
CertificationDiffersCSA C22.2 No. 60950,IEC 60950,METI Denan,UL 60950-1,VDE RoHS,REACHUKCA
Operational conditionsidentical
Operating temperature (T-T)Known for one-5 - 60 °CUnknown — not stated by the source
Storage temperature (T-T)Known for one-25 - 65 °CUnknown — not stated by the source
Operating relative humidity (H-H)Known for one5 - 95%Unknown — not stated by the source
Storage relative humidity (H-H)Known for one5 - 95%Unknown — not stated by the source
Operating altitudeKnown for one0 - 3000 mUnknown — not stated by the source
Non-operating altitudeKnown for one0 - 15240 mUnknown — not stated by the source
Weight & dimensions3 differ
DepthDiffers44 mm75 mm
HeightDiffers1791 mm1490 mm
WeightDiffers6.84 kg7.4 kg
Packaging contentidentical
Cables includedKnown for oneSerialUnknown — not stated by the source
ManualKnown for oneYesUnknown — not stated by the source
Packaging data4 differ
Package weightDiffers6.47 kg17 kg
Package widthDiffers107 mm132 mm
Package depthDiffers162 mm262 mm
Package heightDiffers2000 mm2110 mm
Technical details1 differ
Halogen freeKnown for oneNoUnknown — not stated by the source
Packaging recycled materialsKnown for oneRecycled cardboardUnknown — not stated by the source
Removable batteryDiffersYesNo
SCIP numberKnown for oneUnknown — not stated by the source31346aed-552c-4a16-81d9-e683a383b6da
Logistics data1 differ
Country of originDiffersIndiaUnited States
Total carbon footprint (kg of CO2e)Known for one2676.8173692539Unknown — not stated by the source
Management featuresidentical
Management platformKnown for oneUnknown — not stated by the sourceNMC3