Product comparison · 2 power distribution units (pdus)

APC NetShelter Rack PDU, Metered, 0U, 5.0kW vs APC Easy PDU Metered 1U 16A

Add a product
  • 28specifications compared
  • 21differ
  • 7identical
  • 21known for one product only

Key differences

The APC Easy PDU Metered 1U 16A has 1 U more rack capacity than the APC NetShelter Rack PDU, Metered, 0U, 5.0kW (1U vs 0U). The APC NetShelter Rack PDU, Metered, 0U, 5.0kW has 14 A more maximum current than the APC Easy PDU Metered 1U 16A (30 A vs 16 A). The APC NetShelter Rack PDU, Metered, 0U, 5.0kW has 1,312 VA more load capacity than the APC Easy PDU Metered 1U 16A (4992 VA vs 3680 VA). PDU types: Basic on the APC NetShelter Rack PDU, Metered, 0U, 5.0kW, Metered on the APC Easy PDU Metered 1U 16A. AC outlets quantity: 42 AC outlet(s) on the APC NetShelter Rack PDU, Metered, 0U, 5.0kW, 8 AC outlet(s) on the APC Easy PDU Metered 1U 16A.

  • PDU types
    • NetShelter Rack PDU, Metered, 0U, 5.0kW:Basic
    • Easy PDU Metered 1U 16A:Metered
  • Rack capacity
    • NetShelter Rack PDU, Metered, 0U, 5.0kW:0U
    • Easy PDU Metered 1U 16A:1U
  • AC outlets quantity
    • NetShelter Rack PDU, Metered, 0U, 5.0kW:42 AC outlet(s)
    • Easy PDU Metered 1U 16A:8 AC outlet(s)
  • Power plug
    • NetShelter Rack PDU, Metered, 0U, 5.0kW:NEMA L6-30P
    • Easy PDU Metered 1U 16A:C13 coupler
  • AC outlet types
    • NetShelter Rack PDU, Metered, 0U, 5.0kW:NEMA L6-30P
    • Easy PDU Metered 1U 16A:C13 coupler
  • Nominal input voltage
    • NetShelter Rack PDU, Metered, 0U, 5.0kW:200; 208 V
    • Easy PDU Metered 1U 16A:230 V
  • AC input frequency
    • NetShelter Rack PDU, Metered, 0U, 5.0kW:50-60 Hz
    • Easy PDU Metered 1U 16A:50/60 Hz
  • Maximum current
    • NetShelter Rack PDU, Metered, 0U, 5.0kW:30 A
    • Easy PDU Metered 1U 16A:16 A

Side by side

Differences highlightedShow differences only (off)
Comparison of AP8841, EPDU2016M
49 specifications
Design2 differ
PDU typesDiffersBasicMetered
TypeSingle-phaseSingle-phase
Rack capacityDiffers0U1U
MountingVerticalVertical
Product colourBlackBlack
Ports & interfaces3 differ
AC outlets quantityDiffers42 AC outlet(s)8 AC outlet(s)
Power plugDiffersNEMA L6-30PC13 coupler
AC outlet typesDiffersNEMA L6-30PC13 coupler
Input connection typeKnown for oneNEMA L6-30PUnknown — not stated by the source
Output connectionsKnown for one36x IEC 320 C13 6x IEC 320 C19Unknown — not stated by the source
Featuresidentical
Cable lengthKnown for one2.9 mUnknown — not stated by the source
Power5 differ
Nominal input voltageDiffers200; 208 V230 V
AC input frequencyDiffers50-60 Hz50/60 Hz
Maximum currentDiffers30 A16 A
Output voltageDiffers200 V; 208 V208 V
Load capacityDiffers4992 VA3680 VA
Maximum input current per phaseKnown for one30 AUnknown — not stated by the source
Maximum total current draw per phaseKnown for one30 AUnknown — not stated by the source
Nominal output voltageKnown for oneUnknown — not stated by the source208 V
Number of phasesKnown for oneUnknown — not stated by the source1
Certificates1 differ
Compliance certificatesDiffersRoHS, REACH, WEEECE, UKCA
Waste Electrical and Electronic Equipment (WEEE) complianceKnown for oneYesUnknown — not stated by the source
CertificationKnown for oneCSA C22.2 No. 60950,IEC 60950,METI Denan,UL 60950-1,VDE RoHS,REACHUnknown — not stated by the source
Operational conditions1 differ
Operating temperature (T-T)Differs-5 - 60 °C-5 - 50 °C
Storage temperature (T-T)-25 - 65 °C-25 - 65 °C
Operating relative humidity (H-H)5 - 95%5 - 95%
Storage relative humidity (H-H)5 - 95%5 - 95%
Operating altitude0 - 3000 m0 - 3000 m
Non-operating altitudeKnown for one0 - 15240 mUnknown — not stated by the source
Weight & dimensions4 differ
WidthDiffers56 mm482 mm
DepthDiffers44 mm100 mm
HeightDiffers1791 mm44 mm
WeightDiffers6.84 kg1.7 kg
Packaging contentidentical
Cables includedKnown for oneSerialUnknown — not stated by the source
ManualKnown for oneYesUnknown — not stated by the source
Packaging data4 differ
Package weightDiffers6.47 kg3 kg
Package widthDiffers107 mm210 mm
Package depthDiffers162 mm570 mm
Package heightDiffers2000 mm680 mm
Technical detailsidentical
Halogen freeKnown for oneNoUnknown — not stated by the source
Packaging recycled materialsKnown for oneRecycled cardboardUnknown — not stated by the source
Preferred mounting positionKnown for oneno preferenceUnknown — not stated by the source
Removable batteryKnown for oneYesUnknown — not stated by the source
Packaging without single use plasticKnown for oneNoUnknown — not stated by the source
Sustainable packagingKnown for oneNoUnknown — not stated by the source
Take-back systemKnown for oneNoUnknown — not stated by the source
Logistics data1 differ
Country of originKnown for oneIndiaUnknown — not stated by the source
Customs product code (TARIC)Known for one8537109899Unknown — not stated by the source
Total carbon footprint (kg of CO2e)Differs2676.8173692539649

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.

More power distribution units (pdus) comparisons