  • PDU types
    • Rack PDU 2G, Metered-by-Outlet, ZeroU, 16A, 100-240V, (21) C13 & (3) C19:Metered, Metered-by-outlet
    • Enterprise C19 PDU:Basic
  • AC outlets quantity
    • Rack PDU 2G, Metered-by-Outlet, ZeroU, 16A, 100-240V, (21) C13 & (3) C19:24 AC outlet(s)
    • Enterprise C19 PDU:6 AC outlet(s)
  • AC outlet types
    • Rack PDU 2G, Metered-by-Outlet, ZeroU, 16A, 100-240V, (21) C13 & (3) C19:C13 coupler, C19 coupler
    • Enterprise C19 PDU:C19 coupler
  • Nominal input voltage
    • Rack PDU 2G, Metered-by-Outlet, ZeroU, 16A, 100-240V, (21) C13 & (3) C19:200-230 V
    • Enterprise C19 PDU:200 - 240 V
  • Maximum current
    • Rack PDU 2G, Metered-by-Outlet, ZeroU, 16A, 100-240V, (21) C13 & (3) C19:20 A
    • Enterprise C19 PDU:60 A
  • Width
    • Rack PDU 2G, Metered-by-Outlet, ZeroU, 16A, 100-240V, (21) C13 & (3) C19:56 mm
    • Enterprise C19 PDU:439 mm
  • Depth
    • Rack PDU 2G, Metered-by-Outlet, ZeroU, 16A, 100-240V, (21) C13 & (3) C19:51 mm
    • Enterprise C19 PDU:213 mm
  • Height
    • Rack PDU 2G, Metered-by-Outlet, ZeroU, 16A, 100-240V, (21) C13 & (3) C19:1829 mm
    • Enterprise C19 PDU:43.9 mm

Side by side

Differences highlightedShow differences only (off)
Comparison of AP8459WW, Enterprise C19 PDU
33 specifications
Design1 differ
PDU typesDiffersMetered, Metered-by-outletBasic
Rack capacityKnown for one0UUnknown — not stated by the source
MountingKnown for oneVerticalUnknown — not stated by the source
Product colourKnown for oneBlackUnknown — not stated by the source
Ports & interfaces2 differ
AC outlets quantityDiffers24 AC outlet(s)6 AC outlet(s)
AC outlet typesDiffersC13 coupler, C19 couplerC19 coupler
Output connectionsKnown for oneUnknown — not stated by the source6 x IEC 320 EN 60320 C19
Featuresidentical
LED indicatorsKnown for oneYesUnknown — not stated by the source
Management featuresidentical
MonitoringKnown for oneCurrent, Power, VoltageUnknown — not stated by the source
Power2 differ
Nominal input voltageDiffers200-230 V200 - 240 V
AC input frequencyKnown for one50 - 60 HzUnknown — not stated by the source
Maximum currentDiffers20 A60 A
Nominal output voltageKnown for one200-230 VUnknown — not stated by the source
Load capacityKnown for one3680 VAUnknown — not stated by the source
Maximum input current per phaseKnown for one16 AUnknown — not stated by the source
Maximum total current draw per phaseKnown for one16 AUnknown — not stated by the source
Maximum powerKnown for one3680 WUnknown — not stated by the source
Certificatesidentical
Compliance certificatesKnown for oneRoHSUnknown — not stated by the source
CertificationKnown for oneEN 55022 Class A, EN 55024, EN 61000-3-2, EN 61000-3-3, FCC Part 15 Class A, ICES-003, PSE, UL Listed, VCCI Class A, VDEUnknown — not stated by the source
Operational conditionsidentical
Operating temperature (T-T)Known for one-5 - 45 °CUnknown — not stated by the source
Storage temperature (T-T)Known for one-25 - 65 °CUnknown — not stated by the source
Operating relative humidity (H-H)Known for one5 - 95%Unknown — not stated by the source
Storage relative humidity (H-H)Known for one5 - 95%Unknown — not stated by the source
Non-operating altitudeKnown for one0 - 15000 mUnknown — not stated by the source
Weight & dimensions4 differ
WidthDiffers56 mm439 mm
DepthDiffers51 mm213 mm
HeightDiffers1829 mm43.9 mm
WeightDiffers5.08 kg9.6 kg
Packaging dataidentical
Package weightKnown for one8.35 kgUnknown — not stated by the source
Package widthKnown for one163 mmUnknown — not stated by the source
Package depthKnown for one117 mmUnknown — not stated by the source
Package heightKnown for one2037 mmUnknown — not stated by the source
Logistics dataidentical
Total carbon footprint (kg of CO2e)Known for one4728.07Unknown — not stated by the source