Product comparison · 2 power distribution units (pdus)

APC Rack PDU 2G, Metered-by-Outlet, ZeroU, 16A, 100-240V, (21) C13 & (3) C19 vs APC IT Power Distribution Module 2 Pole 3 Wire 30A

Add a product
  • 22specifications compared
  • 19differ
  • 3identical
  • 12known for one product only

Key differences

  • PDU types
    • Rack PDU 2G, Metered-by-Outlet, ZeroU, 16A, 100-240V, (21) C13 & (3) C19:Metered, Metered-by-outlet
    • IT Power Distribution Module 2 Pole 3 Wire 30A:Metered, Monitored
  • AC outlets quantity
    • Rack PDU 2G, Metered-by-Outlet, ZeroU, 16A, 100-240V, (21) C13 & (3) C19:24 AC outlet(s)
    • IT Power Distribution Module 2 Pole 3 Wire 30A:1 AC outlet(s)
  • AC outlet types
    • Rack PDU 2G, Metered-by-Outlet, ZeroU, 16A, 100-240V, (21) C13 & (3) C19:C13 coupler, C19 coupler
    • IT Power Distribution Module 2 Pole 3 Wire 30A:NEMA L6-30R
  • Nominal input voltage
    • Rack PDU 2G, Metered-by-Outlet, ZeroU, 16A, 100-240V, (21) C13 & (3) C19:200-230 V
    • IT Power Distribution Module 2 Pole 3 Wire 30A:208 V
  • AC input frequency
    • Rack PDU 2G, Metered-by-Outlet, ZeroU, 16A, 100-240V, (21) C13 & (3) C19:50 - 60 Hz
    • IT Power Distribution Module 2 Pole 3 Wire 30A:60 Hz
  • Nominal output voltage
    • Rack PDU 2G, Metered-by-Outlet, ZeroU, 16A, 100-240V, (21) C13 & (3) C19:200-230 V
    • IT Power Distribution Module 2 Pole 3 Wire 30A:208 V
  • Maximum input current per phase
    • Rack PDU 2G, Metered-by-Outlet, ZeroU, 16A, 100-240V, (21) C13 & (3) C19:16 A
    • IT Power Distribution Module 2 Pole 3 Wire 30A:30 A
  • Maximum total current draw per phase
    • Rack PDU 2G, Metered-by-Outlet, ZeroU, 16A, 100-240V, (21) C13 & (3) C19:16 A
    • IT Power Distribution Module 2 Pole 3 Wire 30A:30 A

Side by side

Differences highlightedShow differences only (off)
Comparison of AP8459WW, IT Power Distribution Module 2 Pole 3 Wire 30A
34 specifications
Design1 differ
PDU typesDiffersMetered, Metered-by-outletMetered, Monitored
Rack capacityKnown for one0UUnknown — not stated by the source
MountingKnown for oneVerticalUnknown — not stated by the source
Product colourBlackBlack
Ports & interfaces2 differ
AC outlets quantityDiffers24 AC outlet(s)1 AC outlet(s)
AC outlet typesDiffersC13 coupler, C19 couplerNEMA L6-30R
Featuresidentical
LED indicatorsYesYes
Cable lengthKnown for oneUnknown — not stated by the source12 m
Management featuresidentical
MonitoringKnown for oneCurrent, Power, VoltageUnknown — not stated by the source
Power5 differ
Nominal input voltageDiffers200-230 V208 V
AC input frequencyDiffers50 - 60 Hz60 Hz
Maximum currentKnown for one20 AUnknown — not stated by the source
Nominal output voltageDiffers200-230 V208 V
Load capacityKnown for one3680 VAUnknown — not stated by the source
Maximum input current per phaseDiffers16 A30 A
Maximum total current draw per phaseDiffers16 A30 A
Maximum powerKnown for one3680 WUnknown — not stated by the source
Certificates1 differ
Compliance certificatesRoHSRoHS
CertificationDiffersEN 55022 Class A, EN 55024, EN 61000-3-2, EN 61000-3-3, FCC Part 15 Class A, ICES-003, PSE, UL Listed, VCCI Class A, VDEUL
Operational conditions5 differ
Operating temperature (T-T)Differs-5 - 45 °C0 - 30 °C
Storage temperature (T-T)Differs-25 - 65 °C-15 - 40 °C
Operating relative humidity (H-H)Differs5 - 95%0 - 95%
Storage relative humidity (H-H)Differs5 - 95%0 - 95%
Non-operating altitudeDiffers0 - 15000 m0 - 4500 m
Operating altitudeKnown for oneUnknown — not stated by the source0 - 3000 m
Weight & dimensions4 differ
WidthDiffers56 mm432 mm
DepthDiffers51 mm406 mm
HeightDiffers1829 mm254 mm
WeightDiffers5.08 kg6.8 kg
Packaging data1 differ
Package weightDiffers8.35 kg7.7 kg
Package widthKnown for one163 mmUnknown — not stated by the source
Package depthKnown for one117 mmUnknown — not stated by the source
Package heightKnown for one2037 mmUnknown — not stated by the source
Logistics dataidentical
Total carbon footprint (kg of CO2e)Known for one4728.07Unknown — not stated by the source

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.

More power distribution units (pdus) comparisons