Product comparison · 2 power distribution units (pdus)

APC AP7750A power distribution unit (PDU) 10 AC outlet(s) 1U Black vs APC Rack PDU 2G, Metered by Outlet with Switching, ZeroU, 20A/208V, 16A/230V, (21) C13 & (3) C19

Add a product
  • 27specifications compared
  • 20differ
  • 7identical
  • 10known for one product only

Key differences

  • Rack capacity
    • AP7750A power distribution unit (PDU) 10 AC outlet(s) 1U Black:1U
    • Rack PDU 2G, Metered by Outlet with Switching, ZeroU, 20A/208V, 16A/230V, (21) C13 & (3) C19:0U
  • Mounting
    • AP7750A power distribution unit (PDU) 10 AC outlet(s) 1U Black:Horizontal
    • Rack PDU 2G, Metered by Outlet with Switching, ZeroU, 20A/208V, 16A/230V, (21) C13 & (3) C19:Vertical
  • AC outlets quantity
    • AP7750A power distribution unit (PDU) 10 AC outlet(s) 1U Black:10 AC outlet(s)
    • Rack PDU 2G, Metered by Outlet with Switching, ZeroU, 20A/208V, 16A/230V, (21) C13 & (3) C19:24 AC outlet(s)
  • AC outlet types
    • AP7750A power distribution unit (PDU) 10 AC outlet(s) 1U Black:NEMA 5–15R
    • Rack PDU 2G, Metered by Outlet with Switching, ZeroU, 20A/208V, 16A/230V, (21) C13 & (3) C19:C13 coupler, C19 coupler
  • Nominal input voltage
    • AP7750A power distribution unit (PDU) 10 AC outlet(s) 1U Black:100 - 120 V
    • Rack PDU 2G, Metered by Outlet with Switching, ZeroU, 20A/208V, 16A/230V, (21) C13 & (3) C19:200-230 V
  • Nominal output voltage
    • AP7750A power distribution unit (PDU) 10 AC outlet(s) 1U Black:100 - 120 V
    • Rack PDU 2G, Metered by Outlet with Switching, ZeroU, 20A/208V, 16A/230V, (21) C13 & (3) C19:200-230 V
  • Load capacity
    • AP7750A power distribution unit (PDU) 10 AC outlet(s) 1U Black:1440 VA
    • Rack PDU 2G, Metered by Outlet with Switching, ZeroU, 20A/208V, 16A/230V, (21) C13 & (3) C19:3680 VA
  • Maximum input current per phase
    • AP7750A power distribution unit (PDU) 10 AC outlet(s) 1U Black:15 A
    • Rack PDU 2G, Metered by Outlet with Switching, ZeroU, 20A/208V, 16A/230V, (21) C13 & (3) C19:16 A

Side by side

Differences highlightedShow differences only (off)
Comparison of AP7750A, AP8659
37 specifications
Design3 differ
PDU typesDiffersSwitchedMetered, Metered-by-outlet, Switched
Rack capacityDiffers1U0U
MountingDiffersHorizontalVertical
Product colourBlackBlack
DisplayKnown for oneLCDUnknown — not stated by the source
Ports & interfaces2 differ
AC outlets quantityDiffers10 AC outlet(s)24 AC outlet(s)
AC outlet typesDiffersNEMA 5–15RC13 coupler, C19 coupler
Power plugKnown for oneNEMA 5–15PUnknown — not stated by the source
Management featuresidentical
MonitoringKnown for oneUnknown — not stated by the sourceCurrent, Power, Voltage
Outlet controlKnown for oneUnknown — not stated by the sourceLock-out, Recycle, Turn off, Turn on
Power4 differ
Nominal input voltageDiffers100 - 120 V200-230 V
AC input frequency50 - 60 Hz50 - 60 Hz
Maximum currentKnown for oneUnknown — not stated by the source16 A
Nominal output voltageDiffers100 - 120 V200-230 V
Load capacityDiffers1440 VA3680 VA
Maximum input current per phaseDiffers15 A16 A
Maximum total current draw per phaseKnown for oneUnknown — not stated by the source16 A
Maximum powerKnown for oneUnknown — not stated by the source3680 W
Certificates1 differ
Compliance certificatesRoHSRoHS
CertificationDiffersFCC 15 A, ICES-003, TUV-C, TUV-NURTL, VCCI AEN 55022 A, EN 55024, EN 61000-3-2, EN 61000-3-3, FCC 15 A, ICES-003, PSE, UL, VCCI A, VDE
Operational conditions2 differ
Operating temperature (T-T)-5 - 45 °C-5 - 45 °C
Storage temperature (T-T)-25 - 65 °C-25 - 65 °C
Operating relative humidity (H-H)Differs0 - 95%5 - 95%
Storage relative humidity (H-H)Differs0 - 95%5 - 95%
Operating altitude0 - 3000 m0 - 3000 m
Non-operating altitude0 - 15000 m0 - 15000 m
Weight & dimensions4 differ
WidthDiffers432 mm56 mm
DepthDiffers236 mm51 mm
HeightDiffers44 mm1829 mm
WeightDiffers4.7 kg6.09 kg
Packaging data4 differ
Package weightDiffers6.48 kg8.36 kg
Package widthDiffers600 mm162 mm
Package depthDiffers356 mm117 mm
Package heightDiffers114 mm2038 mm
Logistics dataidentical
Total carbon footprint (kg of CO2e)Known for oneUnknown — not stated by the source537.26
Featuresidentical
LED indicatorsKnown for oneYesUnknown — not stated by the source
Cable lengthKnown for one2.44 mUnknown — not stated by the source