Product comparison · 2 power distribution units (pdus)

APC 66124 power distribution unit (PDU) Grey vs APC Rack ATS, 2U, 208V

Add a product
  • 9specifications compared
  • 8differ
  • 1identical
  • 8known for one product only

Key differences

  • Product colour
    • 66124 power distribution unit (PDU) Grey:Grey
    • Rack ATS, 2U, 208V:Black
  • Storage temperature (T-T)
    • 66124 power distribution unit (PDU) Grey:-10 - 60 °C
    • Rack ATS, 2U, 208V:-25 - 65 °C
  • Operating relative humidity (H-H)
    • 66124 power distribution unit (PDU) Grey:0 - 95%
    • Rack ATS, 2U, 208V:5 - 95%
  • Storage relative humidity (H-H)
    • 66124 power distribution unit (PDU) Grey:0 - 95%
    • Rack ATS, 2U, 208V:5 - 95%
  • Width
    • 66124 power distribution unit (PDU) Grey:132 mm
    • Rack ATS, 2U, 208V:432 mm
  • Depth
    • 66124 power distribution unit (PDU) Grey:66 mm
    • Rack ATS, 2U, 208V:236 mm
  • Height
    • 66124 power distribution unit (PDU) Grey:42 mm
    • Rack ATS, 2U, 208V:88 mm
  • Weight
    • 66124 power distribution unit (PDU) Grey:70 g
    • Rack ATS, 2U, 208V:6.5 kg

Side by side

Differences highlightedShow differences only (off)
Comparison of 66124, Rack ATS, 2U, 208V
17 specifications
Design1 differ
Product colourDiffersGreyBlack
MountingKnown for oneHorizontalUnknown — not stated by the source
Ports & interfacesidentical
Input connection typeKnown for oneUnknown — not stated by the sourceNEMA L6-30P
Output connectionsKnown for oneUnknown — not stated by the source16x IEC 320 C13 2x IEC 320 C19
Featuresidentical
Cable lengthKnown for oneUnknown — not stated by the source2.44 m
Poweridentical
AC input frequencyKnown for oneUnknown — not stated by the source50 - 60 Hz
Maximum input current per phaseKnown for oneUnknown — not stated by the source30 A
Maximum total current draw per phaseKnown for oneUnknown — not stated by the source30 A
Certificatesidentical
CertificationKnown for oneUnknown — not stated by the sourceEN 55022 Class A,FCC Part 15 Class A,PSE,TUV-C,TUV-NURTL
Operational conditions3 differ
Operating temperature (T-T)-5 - 45 °C-5 - 45 °C
Storage temperature (T-T)Differs-10 - 60 °C-25 - 65 °C
Operating relative humidity (H-H)Differs0 - 95%5 - 95%
Storage relative humidity (H-H)Differs0 - 95%5 - 95%
Weight & dimensions4 differ
WidthDiffers132 mm432 mm
DepthDiffers66 mm236 mm
HeightDiffers42 mm88 mm
WeightDiffers70 g6.5 kg

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.

More power distribution units (pdus) comparisons