Product comparison · 2 power distribution units (pdus)

APC 3 Pole 5 Wire RCD 32A 30mA IEC309 vs APC 66097 power distribution unit (PDU) Grey

Add a product
  • 5specifications compared
  • 4differ
  • 1identical
  • 19known for one product only

Key differences

  • Width
    • 3 Pole 5 Wire RCD 32A 30mA IEC309:432 mm
    • 66097 power distribution unit (PDU) Grey:66 mm
  • Depth
    • 3 Pole 5 Wire RCD 32A 30mA IEC309:406 mm
    • 66097 power distribution unit (PDU) Grey:140 mm
  • Height
    • 3 Pole 5 Wire RCD 32A 30mA IEC309:254 mm
    • 66097 power distribution unit (PDU) Grey:35 mm
  • Weight
    • 3 Pole 5 Wire RCD 32A 30mA IEC309:2.1 kg
    • 66097 power distribution unit (PDU) Grey:300 g

Side by side

Differences highlightedShow differences only (off)
Comparison of 3 Pole 5 Wire RCD 32A 30mA IEC309, 66097
24 specifications
Designidentical
Product colourGreyGrey
MountingKnown for oneUnknown — not stated by the sourceHorizontal
Ports & interfacesidentical
Input connection typeKnown for oneIEC 309 32A 3P+N+PEUnknown — not stated by the source
Output connectionsKnown for one1 x IEC 309 32AUnknown — not stated by the source
Featuresidentical
Cable lengthKnown for one1.4 mUnknown — not stated by the source
Poweridentical
Nominal input voltageKnown for one400 VUnknown — not stated by the source
AC input frequencyKnown for one50 HzUnknown — not stated by the source
Nominal output voltageKnown for one400 VUnknown — not stated by the source
Output voltageKnown for one230 - 400 VUnknown — not stated by the source
Maximum input current per phaseKnown for one32 AUnknown — not stated by the source
Maximum total current draw per phaseKnown for one32 AUnknown — not stated by the source
Weight & dimensions4 differ
WidthDiffers432 mm66 mm
DepthDiffers406 mm140 mm
HeightDiffers254 mm35 mm
WeightDiffers2.1 kg300 g
Packaging dataidentical
Package weightKnown for one3 kgUnknown — not stated by the source
Package widthKnown for one432 mmUnknown — not stated by the source
Package depthKnown for one406 mmUnknown — not stated by the source
Package heightKnown for one254 mmUnknown — not stated by the source
Logistics dataidentical
Warranty periodKnown for one1 year(s)Unknown — not stated by the source
Operational conditionsidentical
Operating temperature (T-T)Known for oneUnknown — not stated by the source-10 - 60 °C
Storage temperature (T-T)Known for oneUnknown — not stated by the source-10 - 60 °C
Operating relative humidity (H-H)Known for oneUnknown — not stated by the source0 - 95%
Storage relative humidity (H-H)Known for oneUnknown — not stated by the source0 - 95%